MR-J3-20A Procurement Questions
What is the rated output of the MR-J3-20A?
The capacity symbol 20 in the model code denotes a rated output of 0.2 kW.
What supply voltage can the MR-J3-20A accept?
The power supply input is 3-phase or 1-phase 200 to 230VAC, 50/60Hz, with permissible voltage fluctuation of 3-phase or 1-phase 170 to 253VAC and permissible frequency fluctuation within ±5%.
What are the output ratings of the MR-J3-20A?
The output rated voltage is 3-phase 170VAC and the output rated current is 1.5 A.
What interface power supply does the MR-J3-20A require?
The interface power supply is 24 VDC ±10% with a power supply capacity of 0.3 A, applicable when all I/O signals are used.
What are the ambient temperature limits for the MR-J3-20A?
In operation the ambient temperature range is 0 to 55 °C (non-freezing) and in storage -20 to 65 °C (non-freezing). When closely mounting amplifiers of 3.5 kW or less, operate at ambient temperatures of 0 to 45 °C or at 75% or smaller effective load ratio.
What enclosure structure and cooling does the MR-J3-20A use?
It uses a natural-cooling, open structure with an IP rating of IP00.
- Model identity
- MR-J3-20A: MELSERVO J3 series servo amplifier; general purpose interface (A); the capacity symbol 20 in the model code denotes the rated output
- Rated output
- 0.2 kW
- Output rated voltage
- 3-phase 170VAC
- Output rated current
- 1.5 A
- Power supply input (voltage / frequency)
- 3-phase or 1-phase 200 to 230VAC, 50/60Hz
- Permissible supply fluctuation
- Permissible voltage fluctuation: 3-phase or 1-phase 170 to 253VAC; permissible frequency fluctuation: within ±5%
- Power supply input rated current
- 1.5 A
- Control circuit power supply
- 1-phase 200 to 230VAC, 50/60Hz; permissible voltage fluctuation 1-phase 170 to 253VAC; permissible frequency fluctuation within ±5%
- Interface power supply
- 24 VDC ±10%; power supply capacity 0.3 A (Note 1: applies when all I/O signals are used)
- Control system
- Sine-wave PWM control, current control system
- Dynamic brake
- Built-in
- Protective functions
- Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal relay), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage, instantaneous power failure protection, overspeed protection, excessive error protection
- Structure (cooling / IP rating)
- Natural-cooling, open (IP rating: IP00)
- Environment
- Ambient temperature: 0 to 55 °C in operation (non-freezing), -20 to 65 °C in storage (non-freezing); ambient humidity: 90%RH or less (non-condensing); altitude: max. 1000 m above sea level; vibration: 5.9 m/s² or less at 10 to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; Note 2 (close mounting, amplifiers of 3.5 kW or less): ambient temperature 0 to 45 °C, or effective load ratio 75% or less
- Device mass
- 0.8 kg