Mitsubishi Electric MR-J4-700B Servo Amplifier

Series#: Mitsubishi

Product Details

  • Mitsubishi Electric MR-J4-700B Servo Amplifier
  • Command interface: SSCNET III/H
  • Main circuit supply: Three-phase 200–240 V AC, 50/60 Hz
  • Rated output voltage: Three-phase 170 V AC
  • Rated output current: 37.0 A

Specification

Mitsubishi Electric MR-J4-700B — Servo Amplifier.

Technical Specifications

SpecificationDetails
ManufacturerMitsubishi Electric
Catalog numberMR-J4-700B
Command interfaceSSCNET III/H
Main circuit supplyThree-phase 200–240 V AC, 50/60 Hz
Rated output voltageThree-phase 170 V AC
Rated output current37.0 A
Controlled axes1
Manufacturer weight reference6.2 kg — Manufacturer product mass; packaging inclusion not specified
Mitsubishi Electric — MELSERVO-J4 catalog L(NA)03058ENG-J, PDF pages 101, 102

MR-J4-700B Procurement Questions

Which servo motors can be combined with the MR-J4-700B?

The 200 V class combinations table lists rotary servo motors HG-SR702, HG-JR503, HG-JR601, HG-JR701M and HG-JR703, and linear servo motors (primary side) LM-FP2F-18M-1SS0 and LM-FP4D-24M-1SS0. Of these, HG-JR503 carries the table's Note 2 marker, meaning the combination increases the maximum torque of the servo motor to 400%.

Can I use a four-wire type load-side encoder with the MR-J4-700B?

No. The MR-J4-_B_ servo amplifier is compatible only with the two-wire type for the load-side encoder interface. For the fully closed loop system and the scale measurement function, the two-wire type connects to CN2; the four-wire type and A/B/Z-phase differential output method have no connector on the MR-J4-_B_ column, and Note 3 states that when the servo motor encoder communication method is four-wire type, MR-J4-_B_ cannot be used — use an MR-J4-_B_-RJ. The two-wire connection is used with software version A3 or later for the fully closed loop system and A8 or later for the scale measurement function.

Are all three listed SSCNET III/H communication cycles selectable?

The listed values are 0.222 ms, 0.444 ms and 0.888 ms, but the communication cycle depends on the controller specifications and the number of axes connected, so not all listed values are selectable under any configuration.

What does the STO safety level depend on?

The functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.

What are the ambient and installation conditions for the MR-J4-700B?

Operation ambient temperature is 0 °C to 55 °C (non-freezing) and storage is -20 °C to 65 °C (non-freezing); ambient humidity is 5 %RH to 90 %RH (non-condensing) for both operation and storage. Use indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt, at 2000 m or less above sea level, with vibration resistance of 5.9 m/s2 at 10 Hz to 55 Hz in the X, Y and Z axes. When using at altitude exceeding 1000 m and up to 2000 m above sea level, follow the restrictions in section 2.7. Close mounting is not allowed on 3-phase supply.

What interface power supply does the MR-J4-700B require?

The interface power supply is 24 V DC ± 10% with a current capacity of 0.3 A (including the CN8 connector signals). Note 1 states that 0.3 A is the value applicable when all I/O signals are used, and the current capacity can be decreased by reducing the number of I/O points; it is not a fixed current draw.

Model identity
MR-J4-700B: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 700 = 7 kW rated output; no power-supply symbol = 3-phase 200 V AC to 240 V AC (200 V class)
Output
Rated voltage 3-phase 170 V AC; rated current 37.0 A
Main circuit power supply input
Voltage/frequency: 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 28.9 A; permissible voltage fluctuation: 3-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Control circuit power supply input
Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.3 A; power consumption 45 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Interface power supply
24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
Control method / dynamic brake
Sine-wave PWM control, current control method; dynamic brake: Built-in
Fully closed loop control / load-side encoder interface
Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B servo amplifier is compatible only with two-wire type (Note 5) (Table 1.1, printed p.1-2: fully closed loop system and scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 4 for fully closed loop; Notes 2, 3, 5 for scale measurement); four-wire type and A/B/Z-phase differential output method — MR-J4-_B_ cannot be used, use an MR-J4-_B_-RJ (Note 3); software version A3 or later (Note 4) / A8 or later (Note 5))
SSCNET III/H communication cycle
SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
Functional safety
STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
Structure (IP rating) / cooling
Force cooling, open (IP20); Note 4: Except for the terminal block.
Environment
Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): not allowed on 3-phase supply; not applicable on 1-phase supply (this model is 3-phase only)
Device mass
6.2 kg
Combinations — rotary servo motors
Combinations with rotary servo motors (200 V class combinations table): HG-SR702, HG-JR503, HG-JR601, HG-JR701M, HG-JR703; of these, HG-JR503 carry the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%)
Combinations — linear / direct drive motors
Combinations (200 V class combinations table): linear servo motors (primary side): LM-FP2F-18M-1SS0, LM-FP4D-24M-1SS0

Technical specifications follow the cited manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say