SICK DT35-B15851 Time-of-flight distance sensor

Series#: SICK

Product Details

  • SICK DT35-B15851 time-of-flight distance sensor (SICK part number 1057653) for non-contact distance measurement.
  • Measuring range is 50–12000 mm at 90% remission, 50–5300 mm at 18% and 50–3100 mm at 6%, specified for speed setting Slow; see manufacturer characteristic curves.
  • Operates on 12–30 VDC; IO-Link requires supply above 18 V and analog voltage output requires supply above 13 V. Use a short-circuit-protected network rated max. 8 A.
  • Q2 can be configured as current output, voltage output or digital output; digital outputs are push-pull PNP/NPN with maximum output current ≤ 100 mA.
  • Infrared laser light source, laser class 1; male M12 5-pin connector; enclosure rating IP65 / IP67.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceDT35-B15851
Device type and manufacturer part numberTime-of-flight distance sensor; SICK part number 1057653
Measuring range by reflectivity50–12000 mm at 90% remission; 50–5300 mm at 18%; 50–3100 mm at 6%; range specified for speed setting Slow; see manufacturer characteristic curves
Supply voltage and output restrictions12–30 VDC; IO-Link requires supply > 18 V; analog voltage output requires supply > 13 V; short-circuit-protected network max. 8 A
IO-LinkIO-Link V1.1; 38.4 kbit/s; process data, parameterization and diagnosis
Digital output1–2 push-pull PNP/NPN outputs depending on Q2 configuration; maximum output current ≤ 100 mA
Q2 configurationSelectable current output, voltage output or digital output
Analog output4–20 mA with load ≤ 450 Ω, or 0–10 V with load ≥ 50000 Ω
Light source and laser classInfrared laser; laser class 1
ConnectionMale M12 connector, 5-pin
Enclosure ratingIP65 / IP67

SICK DT35-B15851 Time-of-flight distance sensor

How do target reflectivity and speed setting affect the measuring range of the DT35-B15851?

The DT35-B15851 measuring range depends on target remission: 50–12000 mm at 90% remission, 50–5300 mm at 18% and 50–3100 mm at 6%. These ranges are specified for speed setting Slow, and the manufacturer characteristic curves should be consulted. The 12000 mm figure therefore applies to targets with 90% remission at the Slow speed setting, not to all objects or all speed settings.

Which supply voltage restrictions apply to IO-Link and analog voltage output on the DT35-B15851?

The DT35-B15851 operates on a 12–30 VDC supply. IO-Link operation requires a supply above 18 V, and the analog voltage output requires a supply above 13 V. The device also has a short-circuit-protected network rated at maximum 8 A.

What functions can the Q2 output of the DT35-B15851 be configured for?

Q2 on the DT35-B15851 is selectable as a current output, a voltage output or a digital output. When configured as a digital output, the device provides 1–2 push-pull PNP/NPN outputs depending on the Q2 configuration, with a maximum output current ≤ 100 mA. These are alternative configurations of Q2, not simultaneous independent ports.

What analog load limits and connector does the DT35-B15851 use?

The DT35-B15851 provides a 4–20 mA analog output with load ≤ 450 Ω, or a 0–10 V analog output with load ≥ 50000 Ω. The electrical connection is a male M12 connector, 5-pin.

Does the DT35-B15851 support IO-Link, and what does it provide?

Yes. The DT35-B15851 supports IO-Link V1.1 at 38.4 kbit/s, providing process data, parameterization and diagnosis. Note that IO-Link operation requires a supply voltage above 18 V.

Device type and manufacturer part number
Time-of-flight distance sensor; SICK part number 1057653
Measuring range by reflectivity
50–12000 mm at 90% remission; 50–5300 mm at 18%; 50–3100 mm at 6%; range specified for speed setting Slow; see manufacturer characteristic curves
Supply voltage and output restrictions
12–30 VDC; IO-Link requires supply > 18 V; analog voltage output requires supply > 13 V; short-circuit-protected network max. 8 A
IO-Link
IO-Link V1.1; 38.4 kbit/s; process data, parameterization and diagnosis
Digital output
1–2 push-pull PNP/NPN outputs depending on Q2 configuration; maximum output current ≤ 100 mA
Q2 configuration
Selectable current output, voltage output or digital output
Analog output
4–20 mA with load ≤ 450 Ω, or 0–10 V with load ≥ 50000 Ω
Light source and laser class
Infrared laser; laser class 1
Connection
Male M12 connector, 5-pin
Enclosure rating
IP65 / IP67

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp