| Specification | Details |
|---|---|
| Manufacturer | SICK |
| Model / order reference | LL3-DB01 |
| Device type and manufacturer part number | Fiber-optic cable; SICK part number 5308074 |
| Functional principle | Proximity system |
| Fiber-optic head | Threaded sleeve; axial light emission |
| Head thread | M6 |
| Qualified sensing range | 1250 mm with WLL80 at 8 ms, visible red light; not an amplifier-independent range |
| Minimum object diameter | 0.015 mm at optimum measuring distance and optimum setting |
| Infrared-light compatibility | No |
| Fiber length | 2000 mm |
| Bending radius | 25 mm |
| Operating temperature | -40 to +70 °C |
| Manufacturer cable weight | 31 g |
The LL3-DB01 is a fiber-optic cable (SICK part number 5308074), not a standalone powered sensor. It is used as part of a proximity system and requires a compatible fiber-optic amplifier to operate.
The LL3-DB01 has a threaded M6 sleeve head with axial light emission, and it is specified for a proximity system configuration.
The 1250 mm qualified sensing range applies with the WLL80 amplifier at 8 ms using visible red light. This is not an amplifier-independent range, so the value should not be assumed for other amplifiers or settings.
The LL3-DB01 fiber is 2000 mm long and has a bending radius of 25 mm. Its operating temperature range is -40 to +70 °C.
No. The LL3-DB01 lists infrared-light compatibility as No, so it should not be applied in infrared sensing setups.
Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.