SICK WLL180T-P432 Fiber-optic amplifier

Series#: SICK

Product Details

  • SICK WLL180T-P432 fiber-optic amplifier, manufacturer part number 6039093, is a stand-alone amplifier using visible red light.
  • Sensing principle and maximum sensing range depend on the optical fiber cable used with the amplifier.
  • It operates from a 12–24 VDC supply, ±10%, and provides 1 PNP output with manually selectable light/dark switching.
  • Connection is via a 4-wire cable, 2 m long.
  • Listed response-time settings are ≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs, with mode-dependent switching frequencies of 31.2 / 7.1 / 2 kHz or 250 / 62.5 Hz; enclosure rating is IP50 according to EN 60529.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceWLL180T-P432
Device type and manufacturer part numberFiber-optic amplifier; SICK part number 6039093
Device configurationStand-alone amplifier; sensing principle and maximum sensing range depend on the optical fiber cable used
Light typeVisible red light
Supply voltage12–24 VDC, ±10%
Digital output1 PNP output; light/dark switching manually selectable
Connection4-wire cable, 2 m
Listed response-time settings≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs; listed alternatives, not a single fixed response time
Listed switching frequencies31.2 / 7.1 / 2 kHz, or 250 / 62.5 Hz; mode-dependent alternatives
Enclosure ratingIP50 according to EN 60529
Manufacturer device weight25 g

SICK WLL180T-P432 Fiber-optic amplifier

Which output type does the WLL180T-P432 provide?

The WLL180T-P432 provides 1 PNP output, with light/dark switching manually selectable. It uses visible red light as its light type.

Is the sensing range of the WLL180T-P432 fixed?

No. The WLL180T-P432 is a stand-alone amplifier, and its sensing principle and maximum sensing range depend on the optical fiber cable used. No single fixed sensing distance applies to the amplifier alone.

What supply voltage and connection does the WLL180T-P432 require?

The WLL180T-P432 operates from 12–24 VDC, ±10%, and connects via a 4-wire cable, 2 m long.

Which response-time settings are listed for the WLL180T-P432?

The listed response-time settings are ≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs; these are listed alternatives rather than a single fixed response time. The listed switching frequencies are 31.2 / 7.1 / 2 kHz, or 250 / 62.5 Hz, as mode-dependent alternatives.

What enclosure rating is specified for the WLL180T-P432?

The WLL180T-P432 has an enclosure rating of IP50 according to EN 60529.

Device type and manufacturer part number
Fiber-optic amplifier; SICK part number 6039093
Device configuration
Stand-alone amplifier; sensing principle and maximum sensing range depend on the optical fiber cable used
Light type
Visible red light
Supply voltage
12–24 VDC, ±10%
Digital output
1 PNP output; light/dark switching manually selectable
Connection
4-wire cable, 2 m
Listed response-time settings
≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs; listed alternatives, not a single fixed response time
Listed switching frequencies
31.2 / 7.1 / 2 kHz, or 250 / 62.5 Hz; mode-dependent alternatives
Enclosure rating
IP50 according to EN 60529

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp