SICK GTB6-P1211 Photoelectric proximity sensor

Series#: SICK

Product Details

  • SICK GTB6-P1211 photoelectric proximity sensor with background suppression, SICK part number 1052440.
  • Sensing range 35–140 mm, with a maximum range of 5–250 mm specified for a target with 90% remission (standard white, DIN 5033).
  • Operates from a 10–30 VDC supply in a short-circuit-protected network rated max. 8 A.
  • PNP digital output with selectable light/dark switching; output current ≤ 100 mA, limited to 50 mA maximum at supply voltage > 24 V.
  • 3-wire cable, 2 m; switching frequency 1000 Hz at light/dark ratio 1:1; enclosure rating IP67.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceGTB6-P1211
Device type and manufacturer part numberPhotoelectric proximity sensor; SICK part number 1052440
Detection principlePhotoelectric proximity sensor with background suppression
Sensing range35–140 mm; maximum 5–250 mm; target with 90% remission (standard white, DIN 5033)
Supply voltage10–30 VDC; operate in a short-circuit-protected network, max. 8 A
Digital outputPNP; selectable light/dark switching
Output current limit≤ 100 mA; at supply voltage > 24 V, maximum is 50 mA
Connection3-wire cable, 2 m
Switching frequency1000 Hz at light/dark ratio 1:1
Enclosure ratingIP67
Manufacturer device weight60 g

SICK GTB6-P1211 Photoelectric proximity sensor

What detection principle and sensing range does the GTB6-P1211 use?

The GTB6-P1211 is a photoelectric proximity sensor with background suppression. Its sensing range is 35–140 mm, and its maximum range is 5–250 mm; the range figures are specified for a target with 90% remission (standard white, DIN 5033), so the usable range depends on target reflectivity.

Which output and connection does the GTB6-P1211 provide?

The GTB6-P1211 provides a PNP digital output with selectable light/dark switching and connects via a 3-wire cable, 2 m long.

How does supply voltage affect the maximum output current of the GTB6-P1211?

The GTB6-P1211 output current limit is ≤ 100 mA, but at a supply voltage > 24 V the maximum is 50 mA. The sensor is designed for a 10–30 VDC supply and should be operated in a short-circuit-protected network, max. 8 A.

What switching frequency and enclosure rating apply to the GTB6-P1211?

The GTB6-P1211 has a switching frequency of 1000 Hz at a light/dark ratio of 1:1 and an enclosure rating of IP67.

Device type and manufacturer part number
Photoelectric proximity sensor; SICK part number 1052440
Detection principle
Photoelectric proximity sensor with background suppression
Sensing range
35–140 mm; maximum 5–250 mm; target with 90% remission (standard white, DIN 5033)
Supply voltage
10–30 VDC; operate in a short-circuit-protected network, max. 8 A
Digital output
PNP; selectable light/dark switching
Output current limit
≤ 100 mA; at supply voltage > 24 V, maximum is 50 mA
Connection
3-wire cable, 2 m
Switching frequency
1000 Hz at light/dark ratio 1:1
Enclosure rating
IP67

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP