ABB CI542-DP PROFIBUS Remote I/O Interface

Series#: ABB

Product Details

  • ABB CI542-DP PROFIBUS Remote I/O Interface
  • Protocol role: PROFIBUS DP V0/V1 slave
  • Onboard digital channels: 8 inputs, 8 outputs and 8 configurable digital I/O channels
  • Preferred terminal units: TU509 or TU510
  • Alternative terminal-unit restriction: TU517/TU518: PROFIBUS baud rate up to 1 Mbaud

Specification

ABB CI542-DP PROFIBUS Remote I/O Interface.

Technical Specifications

SpecificationDetails
ManufacturerABB
Order numberCI542-DP
Protocol rolePROFIBUS DP V0/V1 slave
Onboard digital channels8 inputs, 8 outputs and 8 configurable digital I/O channels
Preferred terminal unitsTU509 or TU510
Alternative terminal-unit restrictionTU517/TU518: PROFIBUS baud rate up to 1 Mbaud
Maximum local expansion10 supported S500 standard or S500-eCo modules
Manufacturer catalog product weight0.154 kg ABB reference, PDF page 151. Manufacturer order-row product weight; not shipping-package mass.

CI542-DP Procurement Questions

What is the order code of the CI542-DP and is it listed as active?

The order code is 1SAP 224 200 R0001, and the lifecycle status is Active.

How many digital inputs and outputs does the CI542-DP provide, and what are their ratings?

It provides 8 digital inputs 24 V DC and 8 digital outputs 24 V DC, 0.5 A max.

Which parts of the PROFIBUS DP configuration must be set on the module itself rather than by the master?

The PROFIBUS DP bus configuration is handled by the PROFIBUS DP master, with the exception of the slave bus ID (via rotary switches) and the transmission rate (automatic detection).

How are the digital I/O channels and the fast counter configured?

The digital I/O channels and the fast counter are configured via software.

Which I/O terminal units can the CI542-DP be plugged on?

It is plugged on the I/O terminal units TU509 or TU510, and accordingly TU517 or TU518.

Order code
1SAP 224 200 R0001 (lifecycle: Active)
I/O channels
8 digital inputs 24 V DC; 8 digital outputs 24 V DC, 0.5 A max.
Configuration
The PROFIBUS DP bus configuration is handled by the PROFIBUS DP master, with the exception of the slave bus ID (via rotary switches) and the transmission rate (automatic detection); the digital I/O channels and the fast counter are configured via software
Terminal units
Plugged on the I/O terminal units TU509 or TU510, and accordingly TU517 or TU518
Weight (catalog ordering data)
0.200 kg/pc

Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp