FM562 Procurement Questions
What is the FM562 used for?
It is a function module for pulse train output (PTO) used for simple positioning tasks with servo drives or stepper drives, providing 2 axes with 2 inputs and 2 pulse-train outputs each.
Are the terminal blocks included with the module?
No. The connection is carried out using removable 9-pin and 11-pin terminal blocks, and these are not included in the module's scope of delivery and must be ordered separately.
Is additional software required to program the FM562?
Yes. For programming, the library package PS552-MC-E is required; it is not part of Automation Builder and has to be purchased separately.
Are the pulse outputs of the two axes galvanically isolated from each other?
No. The pulse outputs of the 2 axes are not galvanically isolated from each other.
What pulse output frequency is specified for the FM562?
The data sheet and hardware manual print a frequency of 10 Hz to 250 kHz, while the main catalog prints a frequency range of 0...250 kHz; both printings are recorded and neither is reconciled.
Which communication interface modules can the FM562 be combined with?
The main catalog lists CI501-PNIO, CI502-PNIO, CI504-PNIO, CI506-PNIO, CI541-DP and CI542-DP as suitable communication interface modules.
- Module role / intended purpose
- Function module for pulse train output (PTO), used for simple positioning tasks with servo drives or stepper drives; provides 2 axes with 2 inputs and 2 pulse-train outputs each
- Pulse train outputs per axis
- 2 pulse train outputs per axis, RS-422
- Digital inputs per axis
- 2 configurable digital inputs per axis, 24 V DC
- Position registers
- 32 bits registers for current position, registered position and speed value
- Pulse output isolation between axes
- The pulse outputs of the 2 axes are not galvanically isolated from each other
- Connectable devices (I/O bus)
- Connectable via the I/O bus connector to S500 PROFIBUS and PROFINET communication interface modules (e. g. CI501-PNIO, CI541-DP), AC500 CPUs and other AC500 I/O modules
- Suitable communication interface modules (main catalog)
- CI501-PNIO, CI502-PNIO, CI504-PNIO, CI506-PNIO, CI541-DP, CI542-DP
- Terminal blocks
- Connection is carried out by using removable 9-pin and 11-pin terminal blocks
- Terminal blocks - scope of delivery
- The terminal blocks are not included in the module's scope of delivery and must be ordered separately
- Digital inputs (data sheet)
- 4 inputs (2 per axis) 24 V DC, can be used as source inputs or as sink inputs
- Input channels 0 and 2 - function
- Input signal used for axis enable and limit switch
- Input channels 1 and 3 - function
- Stop, configurable
- Input data length
- 32 bytes
- Output data length
- 32 bytes
- Pulse outputs per axis (data sheet)
- 2 outputs for each axis, configurable
- Pulse output type
- RS-422 differential signal
- Pulse output mode
- CW & CCW or Pulse & Direction
- PTO frequency (data sheet / HW manual printing)
- 10 Hz to 250 kHz
- PTO frequency range (main catalog printing)
- 0...250 kHz (frequency range as printed in the main catalog technical data — its lower limit differs from the data sheet / HW manual printing; both printings recorded, neither reconciled)
- Pulse number range
- -2147483648 to 2147483647 (32 bits)
- Programming library (PS552-MC-E)
- For programming, the library package PS552-MC-E is required; it is not part of Automation Builder and has to be purchased separately
- Process supply voltage UP - rated value
- 24 V DC (process supply voltage UP, rated value)
- Current consumption via UP terminal
- 42 mA
- Current consumption from CPU power supply
- Ca. 5 mA (current consumption from the 24 V DC power supply at the L+/UP and M/ZP terminals of the CPU/communication interface module)
- Max. power dissipation within the module
- 1.2 W
- Device weight (data sheet / HW manual printing)
- Ca. 125 g (device weight as printed in the data sheet / HW manual technical data; not a shipping weight)
- Weight per piece (main catalog ordering printing)
- 0.15 kg (weight per piece as printed in the main catalog ordering data; differs from the data sheet's device-weight printing — both printings recorded, neither reconciled; not a shipping weight)
- Order code (data sheet printing)
- 1SAP 233 100 R0001 (part number spacing as printed in the data sheet ordering data)
- Product life cycle phase (data sheet printing)
- Classic (as printed in the data sheet ordering data — the later of the two filed printings)
- Product life cycle phase (HW manual printing)
- Active (as printed in the HW manual ordering data — differs from the later data sheet's 'Classic' printing; both printings recorded, neither reconciled)
- Input delay
- Typ. 0.1 ms ... 32 ms (configurable via software), default: 0.1 ms
- Input current per channel at +24 V
- Typ. 5 mA (input current per channel at input voltage +24 V)
- Pulse output channels
- 2 per axis, 4 per module
- Operating temperature (AC500-eCo system data)
- 0 °C ... +60 °C (horizontal mounting of modules; system data as printed in the data sheet)
- Degree of protection (AC500-eCo system data)
- IP 20 (PLC system degree of protection as printed in the data sheet's system data, with all modules or option boards plugged in, all terminals plugged in and all covers closed)
Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.