The R&S®ZVA Vector Network Analyzer extends the capabilities of the R&S®ZVA platform with a frequency range of 10 MHz to 110 GHz, enabling continuous sweep operation for advanced microwave and millimeter-wave measurements. This model integrates all necessary system components for seamless, uninterrupted sweeps (compatible with models 03 and 13), making it a top choice for engineers requiring high-dynamic range and precision in R&D, production, and calibration labs. Its robust design supports electronic power control and power sweeps, ensuring accurate characterization of active and passive components up to the upper frequency limits.
| Parameter | Specification |
|---|---|
| Frequency Range | 10 MHz to 110 GHz |
| Number of Ports | 4 (based on R&S®ZVA67 platform) |
| Continuous Sweep | Yes (models 03 and 13) |
| Output Power | Up to +8 dBm |
| Power Calibration | Up to 110 GHz with R&S power test heads |
| Power Control | Electronic power control and power sweeps |
| System Components | Includes all components for seamless sweep |
| Measurement Modes | Continuous sweep, power sweep, frequency sweep |
| Dynamic Range | High dynamic range (typical > 110 dB) |
| Interface | Standard VNA interfaces (USB, LAN, GPIB) |
| Operating Temperature | +5°C to +40°C |
| Storage Temperature | -20°C to +70°C |
| Dimensions (W x H x D) | 450 mm x 200 mm x 500 mm |
| Weight | Approximately 25 kg |
| Power Supply | 100-240 V AC, 50/60 Hz |
| Compliance | CE, FCC, RoHS |
The family covers R&S®ZVA8 (300 kHz to 8 GHz), R&S®ZVA24 (10 MHz to 24 GHz), R&S®ZVA40 (10 MHz to 40 GHz), R&S®ZVA50 (10 MHz to 50 GHz) and R&S®ZVA67 (10 MHz to 67 GHz), as printed per model.
As printed: R&S®ZVA8 uses type N, female; R&S®ZVA24 uses 3.5 mm, male, ruggedized; R&S®ZVA40 uses 2.92 mm, male, ruggedized, or 2.4 mm, male, ruggedized; R&S®ZVA50 uses 2.4 mm, male, ruggedized; R&S®ZVA67 uses 1.85 mm, male, ruggedized.
The number of test ports is 2 or 4.
The R&S®ZVA8 8 GHz two-port version is order no. 1145.1110.08 and the four-port version is order no. 1145.1110.10.
As printed: 450 W, typ. 310 W (standby: typ. 10 W) for R&S®ZVA8, R&S®ZVA24 (1 or 2 sources), R&S®ZVA40 (1 or 2 sources) and R&S®ZVA50; 650 W, typ. 450 W (standby: typ. 10 W) for R&S®ZVA24 (4 sources), R&S®ZVA40 (4 sources) and R&S®ZVA67.
The operating temperature range is +5 °C to +40 °C and the calibration interval is 1 year.
Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22