The ROHDE & SCHWARZ SMU200A Vector Signal Generator is a premium dual-path instrument designed for the most demanding RF and microwave testing environments. With its ability to generate signals from 100 kHz up to 6 GHz on path A and up to 3 GHz on path B, it provides exceptional flexibility for multi-channel, multi-standard, and MIMO applications. This unit ensures precise, stable output with fast switching speeds, making it a cornerstone for R&D, production, and validation labs worldwide.
| Parameter | Specification |
|---|---|
| Model | ROHDE & SCHWARZ SMU200A |
| Frequency Range – RF Path A | 100 kHz to 2.2 GHz / 3 GHz / 4 GHz / 6 GHz (option dependent) |
| Frequency Range – RF Path B | 100 kHz to 2.2 GHz / 3 GHz (option dependent) |
| Setting Time – SCPI Mode | Typically < 1 ms (frequency and level) |
| Setting Time – List Mode | Typically < 100 µs (frequency and level) |
| Maximum Output Level (Standard) – f ≤ 3 GHz | +13 dBm (PEP) |
| Maximum Output Level (Standard) – f > 3 GHz | +11 dBm (PEP) |
| Maximum Output Level (High-Power Option) – f ≤ 3 GHz | +19 dBm (PEP) |
| Maximum Output Level (High-Power Option) – f > 3 GHz | +17 dBm (PEP) |
| Level Setting Time – SCPI Mode | Typically < 1 ms |
| Level Setting Time – List Mode | Typically < 100 µs |
| Modulation Capabilities | AM, FM, PM, Pulse, I/Q modulation (wideband) |
| Number of RF Outputs | 2 (Path A and Path B, independently configurable) |
| Frequency Resolution | 0.001 Hz |
| Phase Noise (1 GHz, 20 kHz offset) | Typically -130 dBc/Hz |
| SWR (Output, f ≤ 3 GHz) | < 1.5 |
| Operating Temperature Range | 0°C to +50°C |
| Dimensions (W x H x D) | 435 mm x 145 mm x 500 mm |
| Weight | Approx. 18 kg |
No. The base unit carries no RF frequency range of its own; the first RF path must be equipped with one of the four frequency options, with a user-selectable upper frequency limit of 2.2 GHz, 3 GHz, 4 GHz or 6 GHz, and the lower frequency limit of all frequency options is 100 kHz.
As printed: SMU-B102 covers 100 kHz to 2.2 GHz, SMU-B103 100 kHz to 3 GHz, SMU-B104 100 kHz to 4 GHz and SMU-B106 100 kHz to 6 GHz.
Yes, a second RF path can be installed with an upper frequency limit of 2.2 GHz or 3 GHz; the printed options are SMU-B202 (100 kHz to 2.2 GHz) and SMU-B203 (100 kHz to 3 GHz).
The standard setting range is –145 dBm to +20 dBm; with the R&S SMU-B31 or R&S SMU-B36 option it extends to +30 dBm.
Nominal AC input voltage range is 100 V to 240 V with an AC supply frequency of 47 Hz to 63 Hz; remote control is via IEC/IEEE bus, IEC 60625 (IEEE 488) and Ethernet, with command set SCPI 1999.5.
The operating temperature range is +5 °C to +45 °C, and the recommended calibration interval is 3 years.
Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22