Fluke 287 Digital Multimeter

Series#: Fluke

Product Details

  • Fluke 287 True-RMS Electronics Logging Multimeter – the industry benchmark for precision troubleshooting and data logging.
  • True-RMS AC bandwidth up to 100 kHz for accurate measurements on distorted signals and variable frequency drives.
  • Advanced logging capability: stores up to 10,000 readings with interval/event logging and PC connectivity.
  • 0.025% basic DC voltage accuracy and 1 μV resolution for ultra-fine measurements.
  • Rugged design: 1-meter drop tested per IEC/EN 61010-1, MIL-PRF-28800F Class 2 vibration rated.
  • Multi-function display with Min-Max-Avg, Peak (250 μs), dBV/dBm, and conductance measurement.

Specification

The Fluke 287 True-RMS Electronics Logging Multimeter is a high-precision, feature-rich instrument engineered for demanding industrial, laboratory, and field-service environments. With its industry-leading 0.025% basic DC voltage accuracy and 50,000-count resolution, this multimeter delivers the measurement fidelity required for critical troubleshooting and system validation. The Fluke 287 excels in logging applications, storing up to 10,000 time-stamped readings with programmable interval and event triggers, enabling comprehensive trend analysis and long-term monitoring. Its True-RMS AC measurement capability extends to 100 kHz, ensuring reliable readings on complex waveforms common in variable frequency drives and power electronics. A robust design with MIL-PRF-28800F Class 2 vibration resistance and a 1-meter drop rating guarantees durability in harsh conditions. The isolated optical interface and optional wireless connectivity via the Fluke ir3000 FC adapter facilitate seamless data transfer to a PC for detailed analysis. Additional features include dBV/dBm, duty cycle, pulse width, conductance, and a 500 MΩ resistance range, making the Fluke 287 an indispensable tool for advanced electronics and electrical system diagnostics.

Specifications
DC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy 0.025%
AC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy 0.4% (True-RMS)
DC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy 0.05%
AC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy 0.6% (True-RMS)
Temperature (excluding probe) Range / resolution -200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy 1.0%
Resistance Range / resolution 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Basic accuracy 0.05%
Capacitance Range / resolution 1.000 n, 10.00 nF, 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
Basic accuracy 1.0%
Frequency Range / resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy 0.005%
Connectivity Optional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 6 AA alkaline batteries, IECLR6
Battery life 100 hours minimum, 200 hours in logging mode
Temperature Operating -20°C to 55°C
Storage -40°C to 60°C
Relative humidity 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibility EMC EN61326–1
Vibration Random vibration per MIL-PRF-28800F Class 2
Shock 1 meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L) 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight 870.9 g (28 oz)
Multiple on screen displays Yes
True-RMS AC bandwidth 100 kHz
dBV/dBm Yes
DC mV resolution 1 μV
Megohm range Up to 500 MΩ
Conductance 50.00 nS
Continuity beeper Yes
Battery/fuse access Yes/Yes
Elapse time clock Yes
Time of day clock Yes
Min-max-avg Yes
Peak 250 μs
Duty cycle 0.01% to 99.99%
Pulse width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated optical interface Yes
Auto/touch hold Yes
Reading memory Yes
Log to PC Yes
Interval/event logging Yes
Logging memory Up to 10,000 readings
Wireless connectivity (optional) Yes

Fluke 287 Digital Multimeter

What AC and DC voltage ranges does the Fluke 287 cover?

AC ranges are AC mV 50 mV and 500 mV, and AC V 5 V, 50 V, 500 V, 1000 V. DC ranges are DC mV 50 mV and 500 mV, and DC V 5 V, 50 V, 500 V, 1000 V.

What accuracy is specified for AC and DC voltage measurements?

AC voltage accuracy in the 45 to 65 Hz column is 0.3 % + 25. DC voltage accuracy is 0.025 % + 2 on the DC 5 V and 50 V ranges.

What resistance and conductance measurement capability does the 287 have?

Resistance ranges run from 500 Ω to 500 MΩ, with accuracy 0.05 % + 2 on the 5 kΩ range. Conductance is 50 nS with accuracy 1 % + 10.

What temperature range can the meter measure?

Temperature measurement covers -200 °C to +1350 °C with accuracy 1 % + 10; the specification does not include error of the thermocouple probe.

What capacitance range is specified?

Capacitance ranges run from 1 nF to 100 mF.

What safety rating and warranty apply to this meter?

The CSA printing covers CAN/CSA-C22.2 No 61010-1-04 to 1000 V Measurement Category III and 600 V Measurement Category IV, Pollution Degree 2. The 280 Series DMM carries a Lifetime Limited Warranty.

Product type
True-rms digital multimeter, Model 287 (287/289 series)
Maximum voltage between any terminal and earth ground
1000 V
Battery type / battery life
6 AA alkaline batteries, NEDA 15A IEC LR6; battery life 100 hours minimum, 200 hours in Logging mode
Operating temperature
-20 °C to 55 °C
Storage temperature
-40 °C to 60 °C
Operating altitude
3,000 m
Size (HxWxL) - device dimensions
8.75 in x 4.03 in x 2.38 in (22.2 cm x 10.2 cm x 6.0 cm)
Device weight, as printed
28.0 oz (871 g)
Safety standards (CSA printing)
CAN/CSA-C22.2 No 61010-1-04 to 1000 V Measurement Category III and 600 V Measurement Category IV, Pollution Degree 2
Warranty
Lifetime Limited Warranty (280 Series DMM)
AC voltage ranges
AC mV 50 mV and 500 mV; AC V 5 V, 50 V, 500 V, 1000 V
AC voltage accuracy (45 to 65 Hz column)
0.3 % + 25 (45 to 65 Hz)
DC voltage ranges
DC mV 50 mV and 500 mV; DC V 5 V, 50 V, 500 V, 1000 V
DC voltage accuracy
0.025 % + 2 (DC, 5 V and 50 V ranges)
AC current accuracy
0.6 % + 20 (AC μA 500 μA range, 45 Hz to 1 kHz)
DC current accuracy
0.3 % + 10 (DC A 5 A range, DC column)
Resistance (the 50 ohm row is 289 only and is excluded)
ranges 500 Ω to 500 MΩ (the 50 Ω row is Model 289 only and is excluded); accuracy 0.05 % + 2 (5 kΩ range)
Conductance
50 nS; accuracy 1 % + 10
Temperature range and accuracy
-200 °C to +1350 °C; accuracy 1 % + 10
Capacitance range
1 nF to 100 mF
Diode test (bench-amended value - see MANIFEST)
Diode Test row of the Capacitance and Diode Test Specifications table - the row’s printed range and accuracy lie outside the filed quote’s line range and are not carried (bench-amended value)
Frequency counter
99.999 Hz to 999.99 kHz; accuracy 0.005 % + 5
Peak response
250 μS (peak)

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp