Fluke 725 Process Calibrator

Series#: Fluke

Product Details

  • The Fluke 725 Multifunction Process Calibrator is the industry standard for precision calibration of process instruments.
  • Simultaneous measurement and sourcing of voltage, current, resistance, frequency, and temperature for efficient troubleshooting.
  • Supports 13 thermocouple types and 7 RTD types with high accuracy, including custom curves.
  • Built-in 24 V loop power supply with short circuit protection for powering transmitters.
  • Rugged, handheld design with a large dual display for clear, simultaneous readings.

Specification

The Fluke 725 Multifunction Process Calibrator is a versatile, high-accuracy tool designed for process control technicians who need to calibrate, troubleshoot, and verify a wide range of industrial instrumentation. This rugged calibrator combines sourcing and measuring capabilities for DC voltage, DC current, resistance, frequency, and temperature (RTDs and thermocouples) in a single, handheld device. Its dual display allows you to view input and output signals simultaneously, making it ideal for loop checks and transmitter calibration. With support for 13 thermocouple types and 7 RTD types, plus a built-in 24 V loop power supply, the Fluke 725 is a complete solution for maintaining process control systems.

Measurement Accuracy
Voltage DC 30.000 V 0.02% + 2 counts (upper display)
30.000 V 0.02% + 2 counts (lower display)
100.00 mV 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency 2.0 to 1000.0 CPM 0.05% + 1 count
1.0 to 1100.0 Hz 0.05% + 1 count
1.00 to 10.00 kHz 0.05% + 1 count
Sensitivity 1 V peak-to-peak minimum
Pressure Accuracy from 0.025% of range using any of 29 pressure modules (modules available for differential, gauge, vacuum, absolute, dual, and high pressure)
Source Accuracy
Voltage DC 100.00 mV 0.02% + 2 counts
10.000 V 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (source) 0.02% + 2 counts
24.000 mA (simulate) 0.02% + 2 counts
Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency 2.0 to 1000.0 CPM 0.05%
1.0 to 1100.0 Hz 0.05%
1.00 to 10.00 kHz 0.25%
Waveform 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.8°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F; B, R, S: 1°C, 1°F
XK 0.6°C
BP 1.2°C
Source accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
Accuracy stated for 4-wire measurement.
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.4°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C; B, R, S: 1°C
XK 0.6°C
BP 1.2°C
Specifications
Ramp functions Source functions Voltage, current,

Fluke 725 Process Calibrator

Does the Fluke 725 have its own internal pressure range?

No internal pressure range is stated for the 725. The manual states that pressure range, resolution and accuracy are determined by the pressure module, and the printed unit list includes psi, inH2O@4 °C, inH2O@20 °C, kPa, cmH2O@4 °C, cmH2O@20 °C, bar, mbar, kg/cm2, mmHg and inHg.

Which thermocouple types can the 725 measure and source?

The manual lists J, K, T, E, R, S, B, L, N, U, XK and BP for measure and source. Resolution is 0.1 °C and 0.1 °F for J, K, T, E, L, N, U, XK and BP, and 1 °C and 1 °F for B, R and S.

What accuracy does the 725 specify for type K thermocouples?

For type K, the manual gives 1.2 °C accuracy over -200 to 0 °C and 0.8 °C accuracy over 0 to 1370 °C.

What does the 725's loop power supply provide?

The loop power supply is 24 V with a maximum current of 22 mA and is short circuit protected.

What are the 725's operating and storage temperature ranges?

Operating temperature is -10 °C to 55 °C and storage temperature is -20 °C to 71 °C.

What power source does the 725 use?

The manual specifies power requirements of 4 AA alkaline batteries.

Product type
Fluke 725 Multifunction Process Calibrator
Manual edition (binding document)
Users Manual, October 1998 Rev.3, 5/04
Warranty period
three years (warranty period begins on the date of shipment)
DC voltage measurement
30 V (upper display) and 20 V (lower display) ranges at 0.001 V resolution, accuracy 0.02 % + 2; 90 mV range at 0.01 mV resolution, accuracy 0.02 % + 2
DC voltage source
100 mV range at 0.01 mV resolution and 10 V range at 0.001 V resolution, accuracy 0.02 % + 2; maximum load 1 mA
Millivolt measurement and source
-10 mV to 75 mV, 0.01 mV resolution, accuracy ±(0.025 % + 1 count); maximum input voltage 30 V
DC mA measurement and source
24 mA range, 0.001 mA resolution, accuracy 0.02 % + 2; drive capability 1000 Ω at 20 mA
Ohms measurement
0 to 400 Ω (accuracy 0.1 Ω, 4-wire), 400 to 1.5 kΩ (0.5 Ω), 1.5 to 3.2 kΩ (1 Ω)
Ohms source
ranges 15 to 400 Ω, 400 to 1.5 kΩ, 1.5 to 3.2 kΩ; resolution 0.1 Ω (15 to 400 Ω) and 1 Ω (400 to 3.2 kΩ)
Frequency measurement
2.0 to 1000.0 CPM, 1 to 1000 Hz, 1.0 to 10.0 kHz; accuracy ± (0.05 % + 1 count)
Frequency source
2.0 to 1000.0 CPM and 1 to 1000 Hz at ± 0.05 % of output frequency; 1.0 to 10.0 kHz at ± 0.25 %; waveform 5 V p-p squarewave, -0.1 V offset
Thermocouple types (measure and source)
J, K, T, E, R, S, B, L, N, U, XK, BP (measure and source)
Thermocouple type K
K: -200 to 0 °C accuracy 1.2 °C; 0 to 1370 °C accuracy 0.8 °C
Thermocouple type J
J: -200 to 0 °C accuracy 1.0 °C; 0 to 1200 °C accuracy 0.7 °C
Thermocouple resolution
J, K, T, E, L, N, U, XK, BP: 0.1 °C, 0.1 °F; B, R, S: 1 °C, 1 °F
RTD Pt100-385
Pt100-385: -200 to 800 °C; measure accuracy 0.33 °C (4-wire), source accuracy 0.33 °C
RTD Ni120
Ni120: -80 to 260 °C; measure accuracy 0.2 °C (4-wire), source accuracy 0.2 °C
RTD resolution
0.1 °C, 0.1 °F
Loop power supply
24 V; maximum current 22 mA; short circuit protected
Pressure measurement (determined by pressure module)
range, resolution and accuracy determined by the pressure module; units: psi, inH2O@4 °C, inH2O@20 °C, kPa, cmH2O@4 °C, cmH2O@20 °C, bar, mbar, kg/cm2, mmHg, inHg
Operating temperature
-10 °C to 55 °C
Storage temperature
-20 °C to 71 °C
Operating altitude
3000 meters above mean sea level
Safety
EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Power requirements
4 AA alkaline batteries
Size - device dimensions
96 x 200 x 47 mm (3.75 x 7.9 x 1.86 in)
Device weight, as printed
650 gm (1 lb, 7 oz)

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP