Omron CJ1W-OD201 CJ-Series 8-Point Sinking Transistor Output Unit

Series#: Omron

Product Details

  • Omron CJ1W-OD201 CJ-Series 8-Point Sinking Transistor Output Unit
  • Digital outputs: 8
  • Output type: Sinking transistor
  • Rated load voltage: 12–24 VDC
  • Operating load-voltage range: 10.2–26.4 VDC

Specification

Omron CJ1W-OD201 CJ-Series 8-Point Sinking Transistor Output Unit.

Technical Specifications

SpecificationDetails
ManufacturerOmron
Order numberCJ1W-OD201
Digital outputs8
Output typeSinking transistor
Rated load voltage12–24 VDC
Operating load-voltage range10.2–26.4 VDC
Maximum load current2.0 A/point; 8.0 A/unit
Common/circuit arrangement4 points/common, 2 circuits
ON/OFF response time0.5 ms max. ON; 1.0 ms max. OFF
Fuse replacementNot user-replaceable
Manufacturer maximum product weight110 g max. Omron reference, PDF page 9

CJ1W-OD201 Procurement Questions

What is the rated voltage and operating load voltage range of the CJ1W-OD201?

The rated voltage is 12 to 24 V DC, and the operating load voltage range is 10.2 to 26.4 V DC.

How much current can each point and the whole unit handle?

The maximum load current is 2.0 A/point and 8.0 A/Unit.

How is the output circuit configured?

The unit has 8 circuits configured as 4 points/common, 2 circuits.

What external power supply does this unit require?

An external power supply of 12 to 24 V DC, 10 mA min. is required.

Can the fuse be replaced by the user?

The fuse is 6.3 A (1/common, 2 used), and it cannot be replaced by the user.

What are the ON and OFF response times?

The ON response time is 0.5 ms max. and the OFF response time is 1.0 ms max.

Unit classification
Transistor Output Unit (Terminal Block, 8 Points, Sinking)
Rated voltage
12 to 24 V DC
Operating load voltage range
10.2 to 26.4 V DC
Max. load current
2.0 A/point, 8.0 A/Unit
Max. inrush current
10 A/point, 10 ms max.
Leakage current
0.1 mA max.
Residual voltage
1.5 V max.
ON response time
0.5 ms max.
OFF response time
1.0 ms max.
Insulation resistance
20 MΩ between the external terminals and the GR terminal (100 V DC)
Dielectric strength
1,000 V AC between the external terminals and the GR terminal for 1 minute at a leakage current of 10 mA max.
Number of circuits
8 (4 points/common, 2 circuits)
Internal current consumption
5 V DC: 90 mA max.
Fuse
6.3 A (1/common, 2 used) The fuse cannot be replaced by the user.
External power supply
12 to 24 V DC, 10 mA min.
Device weight
110 g max.

Technical facts follow the cited manufacturer reference and exact model column or explicit model-number legend. Numeric weight remains only in the specifications table with its documented product/max/unpacked basis; no shipping mass is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp