Siemens 6ES5541-8AA11 L2 Interface

Series#: Siemens

Product Details

  • 6ES5541-8AA11 – Siemens SIMATIC S5 CP 541 PROFIBUS L2 Interface Module
  • Dedicated PROFIBUS DP (L2) communication processor for S5-115U, S5-135U, and S5-155U PLCs
  • Supports master/slave operation with up to 125 nodes per segment
  • Integrated RS-485 interface with optical isolation for reliable industrial networking
  • Compact single-slot module with easy configuration via COM 541 software

Specification

The Siemens 6ES5541-8AA11 is a high-performance communication processor designed for the SIMATIC S5 family, specifically engineered to interface with PROFIBUS L2 (DP) networks. This CP 541 module enables seamless data exchange between S5 controllers and distributed I/O devices, drives, or other PLCs in demanding automation environments. With its robust RS-485 interface and support for both master and slave modes, the 6ES5541-8AA11 ensures deterministic communication with baud rates up to 12 Mbps. Ideal for legacy system upgrades or new installations requiring reliable fieldbus connectivity, this module is a critical component for maintaining or extending S5-based automation lines.

Parameter Specification
Product Type Communication Processor (CP 541)
Model Number 6ES5541-8AA11
System Compatibility Siemens SIMATIC S5 (S5-115U, S5-135U, S5-155U)
Network Protocol PROFIBUS DP (L2) – EN 50170
Interface Type RS-485, optically isolated
Max. Baud Rate 12 Mbps
Max. Nodes per Segment 125 (without repeater)
Operating Modes Master (Class 1), Slave (Class 2), or DP/M
Data Transmission Half-duplex, token passing with cyclic/acyclic services
Memory Capacity 128 KB RAM for parameter/data buffering
Power Supply 5 V DC via backplane bus; typical current 0.8 A
Power Dissipation 4 W typical
Form Factor Single-width S5 module (approx. 40 mm wide)
Configuration Software COM 541 (version 2.0 or higher) for Windows/STEP 5
Diagnostic Features LED indicators (BUS, ACT, ERR); bus status via software
Operating Temperature 0 °C to +55 °C
Storage Temperature -25 °C to +70 °C
Humidity 5% to 95% non-condensing
Protection Class IP20 (open-type device)
Weight Approx. 0.3 kg
Certifications CE, cULus, PROFIBUS Interoperability Tested

Siemens 6ES5541-8AA11 L2 Interface

What is the CP 541 6ES5 541-8AA11 used for?

It connects a programmable controller of the SIMATIC S5 family via the CP 541 to SINEC L2.

Which transmission rates can be set on this module?

The rates adjustable in DB1 are 93.75 Kbps, 187.5 Kbps and 500 Kbps; the maximum rate is 1500 Kbps, also adjustable in DB1.

What interface and access method does the module use on SINEC L2?

It has an RS 485 interface with bit-serial transmission and protocol to DIN 19245 Part 1; access is token passing between active stations and master-slave between active and passive stations.

How many connections does the module support?

PLC-PLC 29 connections, broadcast 125 connections, and DP connection 1 to DP master; message length is 64 bytes max. for PLC-PLC and broadcast.

What supply voltage and current does the module require?

The rated input voltage is 24 VDC with a permissible range of 20 ... 30 VDC including ripple (Upp max = 3 V); current consumption is 200 mA typical from 24 V and power dissipation is 4.8 W.

What are the permitted operating temperatures for this module?

0 ... +60 °C for horizontal installation and 0 ... +40 °C for vertical installation; storage/transportation is -40 ... +70 °C.

Manual scope / model identity
CP 541, order no. 6ES5 541-8AA11, from revision level 01
Function
Connects a programmable controller of the SIMATIC S5 family via the CP 541 to SINEC L2
Dimensions (H x W x D)
162 mm x 46 mm x 120 mm
Weight
415 g
Input voltage
Rated value 24 VDC; permissible range 20 ... 30 VDC including ripple (Upp max = 3 V)
Current consumption / power dissipation
200 mA typical from 24 V; power dissipation 4.8 W
Transmission rates (adjustable in DB1)
93.75 Kbps; 187.5 Kbps; 500 Kbps (adjustable in DB1; maximum rate 1500 Kbps in f11)
Communication modes / connections
PLC-PLC 29 connections; broadcast 125 connections; DP connection 1 to DP master; message length 64 bytes max. (PLC-PLC and broadcast)
Interface / protocol
RS 485 interface, bit-serial transmission, protocol to DIN 19245 Part 1; token passing between active stations, master-slave between active and passive stations
Operating temperature
0 ... +60 °C (horizontal installation); 0 ... +40 °C (vertical installation); storage/transportation -40 ... +70 °C
Transmission rate, maximum
1500 Kbps (adjustable in DB1)

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp