Siemens 6ES7518-4AX00-1AB0 S7-1500 CPU 1518-4 PN/DP MFP

Series#: Siemens

Product Details

  • Siemens 6ES7518-4AX00-1AB0 S7-1500 CPU 1518-4 PN/DP MFP
  • Manual firmware profile: V3.1, equipment manual 09/2025
  • SIMATIC Memory Card: Required; minimum 2 GB, maximum 32 GB
  • Integrated interface count: 3 PROFINET/Ethernet interfaces and 1 PROFIBUS interface, per manufacturer table
  • X3 Ethernet connection: 1 RJ45 port; C/C++ Runtime reachable; no PROFINET IO Controller or IO Device role

Specification

Siemens 6ES7518-4AX00-1AB0 S7-1500 CPU 1518-4 PN/DP MFP.

Technical Specifications

SpecificationDetails
ManufacturerSiemens
Order number6ES7518-4AX00-1AB0
Manual firmware profileV3.1, equipment manual 09/2025
SIMATIC Memory CardRequired; minimum 2 GB, maximum 32 GB
Integrated interface count3 PROFINET/Ethernet interfaces and 1 PROFIBUS interface, per manufacturer table
X3 Ethernet connection1 RJ45 port; C/C++ Runtime reachable; no PROFINET IO Controller or IO Device role
X4 PROFIBUS roleDP master; not DP device
Rated supply24 V DC
Rated / maximum input current1.7 A / 2 A
Dimensions (W x H x D)175 x 147 x 129 mm
Engineering for FW V3.1STEP 7 TIA Portal V19
Manufacturer approximate product weightApproximately 2093 g Siemens reference, PDF page 62. Product/reference configuration only; shipping mass is not inferred.

6ES7518-4AX00-1AB0 Procurement Questions

What exactly is supplied under article 6ES7518-4AX00-1AB0?

The article is the supply bundle whose component is the CPU 1518-4 PN/DP MFP with C/C++ Runtime preinstalled. The technical specifications on this card describe that CPU component.

Which engineering software version is needed for the CPU component?

The CPU component is engineered with TIA Portal from V18 (FW V3.0), or V15 (FW V2.5) or higher.

Is a SIMATIC Memory Card needed, and what capacity does the CPU component support?

Yes, a SIMATIC Memory Card is required. The plug-in load memory supports up to 32 Gbyte, and the memory card must have at least 2 GB of space on it.

What supply voltage does the CPU component use?

The rated DC supply voltage is 24 V, with a permissible range from 19.2 V to 28.8 V, and reverse polarity protection is included.

What are the ambient temperature limits for horizontal installation?

For horizontal installation the operating ambient temperature range is 0 °C to 60 °C; for the display the limit is 50 °C, and at an operating temperature of typically 50 °C the display is switched off.

Which communication interfaces does the CPU component provide?

The CPU component has 3 PROFINET interfaces and 1 PROFIBUS interface.

Article number
6ES7518-4AX00-1AB0
Siemens short description (product banner)
SIMATIC S7-1500, CPU 1518-4 PN/DP MFP, central processing unit with C/C++ Runtime preinstalled, 6 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: Ethernet, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card (min. 2 GB) required
Product type designation
CPU 1518-4 PN/DP MFP
HW functional status
FS04
Firmware version
V3.0
I&M data
Yes; I&M0 to I&M3
Isochronous mode
Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central)
Engineering with TIA Portal
V18 (FW V3.0); V15 (FW V2.5) or higher
Display diagonal
6.1 cm
Supply voltage, rated value (DC)
24 V
Supply voltage, permissible range lower limit (DC)
19.2 V
Supply voltage, permissible range upper limit (DC)
28.8 V
SIMATIC Memory Card required
Yes
Reverse polarity protection
Yes
Input current, rated value
1.7 A
Inrush current, max.
2 A; Rated value
Infeed power to the backplane bus
12 W
Power loss (typ.)
29 W
Work memory, program
6 Mbyte
Work memory, data
60 Mbyte
Load memory, plug-in (SIMATIC Memory Card), max.
32 Gbyte; the memory card must have at least 2 GB of space on it
CPU processing time, bit operations
1 ns
CPU processing time, word operations
2 ns
CPU processing time, fixed-point arithmetic
2 ns
CPU processing time, floating-point arithmetic
6 ns
CPU block elements, total
20 000; Blocks (OB, FB, FC, DB) and UDTs
Number of PROFINET interfaces
3
Number of PROFIBUS interfaces
1
Ambient temperature during operation, horizontal installation, min.
0 °C
Ambient temperature during operation, horizontal installation, max.
60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
Installation altitude above sea level, max.
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Width
175 mm
Height
147 mm
Depth
129 mm
Device weight, approx. (as printed)
2 093 g

Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp