Allen-Bradley 1785-L40C15 PLC-5/40C Processor with ControlNet

Series#: AllenBradley

Product Details

  • 1785-L40C15 PLC-5/40C Processor with ControlNet interface and 48K SRAM memory.
  • Integrated ControlNet communication port for deterministic, high-speed I/O and peer-to-peer networking.
  • 48K words of SRAM battery-backed user memory, ideal for medium to large-scale control applications.
  • Supports up to 2048 local I/O points and 3072 remote I/O points via ControlNet.
  • Hot-swappable battery and memory module for minimal downtime during maintenance.
  • Backward compatible with existing PLC-5 chassis and 1771 I/O modules, simplifying upgrades.

Specification

The Allen-Bradley 1785-L40C15 is a robust PLC-5/40C processor designed for demanding industrial automation environments. This unit integrates a ControlNet interface directly on the processor module, enabling high-speed, deterministic communication for coordinated control of distributed I/O and drives. With 48K SRAM (battery-backed), it provides ample memory for complex logic, data tables, and recipe management. The 1785-L40C15 excels in applications requiring both local and remote I/O control, supporting up to 2048 local and 3072 remote I/O points. It features a built-in real-time clock for time-stamped data logging and event sequencing, and its modular design allows easy field replacement without disconnecting wiring. This processor is engineered for longevity and reliability, making it a trusted choice for critical processes in manufacturing, oil and gas, and power generation sectors.

Specification Details
Model Number 1785-L40C15
Product Type PLC-5/40C Processor with ControlNet
User Memory 48K words (SRAM, battery-backed)
Communication Ports 1 x ControlNet (coaxial BNC), 1 x Serial (RS-232/422/485), 1 x DH+
ControlNet Data Rate 5 Mbps
Local I/O Capacity Up to 2048 points (discrete) or 512 analog channels
Remote I/O Capacity (via ControlNet) Up to 3072 points
Memory Backup Lithium battery (1785-BA), typical life 2-5 years
Real-Time Clock Yes, battery-backed
Processor Speed 0.5 ms per 1K of Boolean logic (typical)
Power Supply Requirement +5V DC Standard Models 2.5A (from chassis backplane)
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95% (non-condensing)
Shock Rating 30g peak, 11ms duration (operating)
Vibration Rating 2.0g peak, 10-500 Hz (operating)
Chassis Compatibility 1771-A1B, -A2B, -A3B, -A4B, -A5B (single-slot) and multi-slot chassis
Weight Approx. 1.2 kg (2.6 lbs)
Dimensions (H x W x D) 12.7 cm x 5.1 cm x 17.8 cm (5.0" x 2.0" x 7.0")
Certifications UL, cUL, CE, CSA, ATEX (Zone 2) for hazardous locations

Allen-Bradley 1785-L40C15 PLC-5/40C Processor with ControlNet

How much user memory does the 1785-L40C15 provide, and is there a per-file limit?

Maximum user memory is 48K words. The processor has a limit of 32K words per data-table file.

What is the maximum total I/O for this processor?

Maximum total I/O is 2048 (any mix), or 2048 in and 2048 out (complementary).

How many remote I/O racks and devices can the 1785-L40C15 support?

Maximum number of remote I/O racks is 15 and maximum number of remote I/O devices is 60. The processor has 2 ports configurable for DH+ or remote I/O (adapter or scanner) and 0 dedicated DH+ ports.

What ControlNet node counts and network update time apply?

ControlNet transmission rate is 5M bit/s and network update time (NUT) is 2 to 100 ms (user selectable). Maximum nodes per link is 48 without a repeater and 99 with repeaters.

What are the operating and storage temperature ranges?

Operating temperature is 0 to 60 degrees C (32 to 140 degrees F); storage temperature is -40 to 85 degrees C (-40 to 185 degrees F).

Which chassis slots and memory modules are supported?

Location is 1771-A1B, -A2B, A3B, -A3B1, -A4B chassis, left-most slot, with keying between 40 and 42 and between 54 and 56. Memory modules are 1785-ME32, 1785-ME64 and 1785-M100; the 1785-ME16 cannot be used with ControlNet PLC-5 processors.

Register posture - evidence-pending (parser limitation, expressly not a supplier-identity dispute); full binding with posture disclosed
Register entry for goods 986: title "Allen-Bradley 1785-L40C15 PLC-5/40C Processor with ControlNet", model_candidate "1785-L40C15", category parser_recovered_evidence_pending, original_job_status held_identity. The register reason states that a parser limitation alone is not a supplier identity dispute and that manufacturer evidence is still required, so the posture is evidence-pending (an acquisition/parser failure class), not a supplier-identity hold; full binding proceeds with the posture disclosed.
Catalog-identity attestation - the manual attests verbatim: catalog number 1785-L40C15 is the PLC-5/40C (exact-string attestation inside the document)
The user manual for the phase 1.5 ControlNet PLC-5 programmable controllers attests the identity mapping verbatim: catalog number 1785-L40C15 is the PLC-5/40C. The record is bound to the full catalog string 1785-L40C15 on this attestation.
Manual cover catalog numbers - 1785-L20C15, 1785-L40C15, 1785-L46C15, 1785-L80C15
The user manual cover lists the catalog numbers 1785-L20C15, 1785-L40C15, 1785-L46C15, and 1785-L80C15 for the ControlNet PLC-5 Programmable Controllers User Manual.
Maximum user memory words - 48K (PLC-5/40C15 column of the Appendix A comparison table)
Maximum user memory words for the PLC-5/40C15 column: 48K (the table prints 16K for PLC-5/20C15, 48K for PLC-5/46C15, and 100K for PLC-5/80C15).
Data-table file limit - 32K words per data-table file (comparison-table footnote 1)
Footnote to the comparison table: the PLC-5/40C15 and -5/46C15 processors have a limit of 32K words per data-table file.
Maximum total I/O - 2048 (any mix), or 2048 in and 2048 out (complementary)
Maximum total I/O for PLC-5/40C15: 2048 (any mix), or 2048 in and 2048 out (complementary).
Program scan time - 0.5 ms per K word (bit logic); 2 ms per K word (typical)
Program scan time: 0.5 ms per K word (bit logic); 2 ms per K word (typical).
Backplane current - 3.3A @ 5Vdc, keyed to the 1785-L40C15 group (the 1997 manual's generic 3.0 A max / 2.7 A typical load line is NOT bound - divergence flagged)
Backplane current: 3.3A @ 5Vdc for the group 1785-L40C15, -L46C15, -L80C15 (1785-L20C15 is printed separately as 2.7A @ 5Vdc).
Heat dissipation - 59 BTU/hour, keyed to the 1785-L40C15 group (the 1997 manual's combined 54 BTU/hr line is NOT bound - divergence flagged)
Heat dissipation: 59 BTU/hour for the group 1785-L40C15, -L46C15, -L80C15 (1785-L20C15 is printed separately as 54 BTU/hour).
Device weight, as printed - 3 lbs, 2 oz (1.42 kg) for PLC-5/40C15; printed device weight only, NOT a shipping weight
Device weight as printed for PLC-5/40C15: 3 lbs, 2 oz (1.42 kg). This is the printed device weight of the processor, not a shipping weight.
Device-weight corroboration - the 1997 manual prints the same 3 lbs, 2 oz (1.42 kg) for the PLC-5/40C
The earlier ControlNet PLC-5 user manual prints the same device weight for the PLC-5/40C: 3 lbs, 2 oz (1.42 kg) (the PLC-5/20C is printed as 3 lbs, 3 oz (1.45 kg)), corroborating the newer manual figure.
Memory/I-O corroboration - the 1997 manual comparison table agrees (48K words, 2048 I/O, scan times, 32K data-table file limit)
The earlier manual comparison table (columns PLC-5/20C and PLC-5/40C) prints maximum user memory words 48K for the PLC-5/40C, maximum total I/O 2048 (any mix) or 2048 in and 2048 out, program scan time 0.5 ms per K word (bit logic) and 2 ms per K word (typical), and the footnote limit of 32K words per data-table file - agreeing with the newer ControlNet PLC-5 user manual.
Operating temperature - 0 to 60 degrees C (32 to 140 degrees F)
Operating temperature: 0 to 60 degrees C (32 to 140 degrees F), per IEC 60068-2-1, IEC 60068-2-2, and IEC 60068-2-14 tests.
Storage temperature - -40 to 85 degrees C (-40 to 185 degrees F)
Storage temperature: -40 to 85 degrees C (-40 to 185 degrees F).
Relative humidity - 5 to 95 percent, non condensing
Relative humidity: 5 to 95 percent, non condensing.
Vibration and shock - vibration 2g at 10 to 500 Hz (the 1997 manual's 1 g is NOT bound - divergence flagged); shock operating 30g, non-operating 50g
Vibration (IEC 60068-2-6, Test Fc, Operating): 2g at 10 to 500 Hz. Shock (IEC 60068-2-27): operating 30g, non-operating 50g.
Enclosure type rating - none (open style)
Enclosure type rating: none (open style).
Battery, memory modules, I/O modules and cartridges - 1770-XYC battery; 1785-ME32 / 1785-ME64 / 1785-M100 memory modules; Bulletin 1771, 1794, 1746 and 1791 I/O
Battery: Allen-Bradley 1770-XYC. Memory modules: 1785-ME32, 1785-ME64, 1785-M100 (footnote: the 1785-ME16 cannot be used with ControlNet PLC-5 processors). I/O modules: Bulletin 1771 I/O, 1794 I/O, 1746 I/O, and 1791 I/O, including 8-, 16-, 32-pt, and intelligent modules. Available cartridges include the 1785-CHBM ControlNet Hot Backup Cartridge and the 1785-RC Relay Cartridge.
Communication interfaces - Serial, DH+, DH using 1785-KA, Remote I/O, ControlNet
Communication interfaces listed for the processor: Serial, DH+, DH using 1785-KA, Remote I/O, and ControlNet.
Location and keying - 1771-A1B, -A2B, A3B, -A3B1, -A4B chassis, left-most slot; keying between 40 and 42 and between 54 and 56
Location: 1771-A1B, -A2B, A3B, -A3B1, -A4B chassis; left-most slot. Keying: between 40 and 42, and between 54 and 56.
ControlNet I/O - 5M bit/s; NUT 2-100 ms; 1 ControlNet port (redundant); 48 nodes without a repeater, 99 with repeaters (the 1997 manual's 107 is NOT bound - divergence flagged); 96 I/O map entries
ControlNet I/O: transmission rate 5M bit/s; network update time (NUT) 2 to 100 ms (user selectable); number of ControlNet ports 1 (redundant); maximum number of nodes per link 48 without a repeater and 99 with repeaters; maximum number of I/O map entries: 96.
DH+/remote I/O channels - 2 ports configurable for DH+ or remote I/O (adapter or scanner), 0 dedicated DH+ ports; transmission rates 57.6K, 115.2K and 230.4K bit/s
Remote I/O and DH+ channels for PLC-5/40C15: 2 ports configurable for DH+ or remote I/O (adapter or scanner), and 0 dedicated DH+ ports; transmission rates 57.6K bit/s, 115.2K bit/s, and 230.4K bit/s.
Remote I/O capacity - maximum 15 remote I/O racks (the 1997 manual's 16 is NOT bound - divergence flagged); maximum 60 remote I/O devices
Maximum number of remote I/O racks for PLC-5/40C15: 15; maximum number of remote I/O devices: 60.
Serial ports, coprocessor ports, MCPs - 1 serial port, 1 coprocessor port, maximum 16 MCPs
Number of serial ports: 1. Number of coprocessor ports: 1. Maximum number of MCPs: 16.

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp