Allen-Bradley 1794-TB3T FLEX I/O Terminal Base

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-TB3T FLEX I/O Terminal Base
  • Termination type: Cage clamp, temperature
  • Terminal arrangement: 16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
  • Operating temperature: -20…+70 °C (-4…+158 °F)

Specification

Allen-Bradley 1794-TB3T FLEX I/O Terminal Base.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-TB3T
Termination typeCage clamp, temperature
Terminal arrangement16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
Operating temperature-20…+70 °C (-4…+158 °F)

1794-TB3T Procurement Questions

Which modules is the 1794-TB3T intended to be used with?

It is a cage clamp terminal base to be used with the 1794-IT8 or 1794-IRT8 module when used in thermocouple mode, and it also provides chassis ground connections for the 1794-IR8 and analog modules.

What connection points does this terminal base provide?

It provides 16 I/O; 10 common; 4 +V; 8 chassis ground; and 2 sets of CJC for temperature modules.

What wire size can be terminated on this base?

The common terminal base characteristic is 0.34…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, with 1.2 mm (3/64 in.) insulation max.

What are the dimensions of this terminal base?

The common terminal base dimension is 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in).

What is the operating temperature range?

The operating temperature range is -20…+70 °C (-4…+158 °F).

What application voltage range applies to this base?

It is used in applications up to 132V AC/156V DC.

Wire size (common terminal base characteristic)
0.34…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater; 1.2 mm (3/64 in.) insulation max
Dimensions (HxWxD) (common terminal base characteristic)
94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in)
Termination type
Cage clamp, temperature
Connections
16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
Used in applications
Up to 132V AC/156V DC
Wiring category
Module dependent
Purpose
A cage clamp terminal base to be used with the 1794-IT8 or 1794-IRT8 module (when used in thermocouple mode) – also provides chassis ground connections for the 1794-IR8 and analog modules
Temperature, operating
-20…+70 °C (-4…+158 °F)

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp