Allen-Bradley 1794-TB3TS FLEX I/O Terminal Base

Series#: AllenBradley

Product Details

  • Allen-Bradley 1794-TB3TS FLEX I/O Terminal Base
  • Termination type: Spring clamp, temperature
  • Terminal arrangement: 16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
  • Operating temperature: -20…+70 °C (-4…+158 °F)

Specification

Allen-Bradley 1794-TB3TS FLEX I/O Terminal Base.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1794-TB3TS
Termination typeSpring clamp, temperature
Terminal arrangement16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
Operating temperature-20…+70 °C (-4…+158 °F)

1794-TB3TS Procurement Questions

What termination style does the 1794-TB3TS use?

It uses spring clamp, temperature termination.

How many connection points does the 1794-TB3TS provide?

It provides 16 I/O; 10 common; 4 +V; 8 chassis ground; and 2 sets of CJC for temperature modules.

What voltage range is the 1794-TB3TS used in applications for?

It is used in applications up to 132V AC/156V DC.

What wire size and insulation limit apply to the 1794-TB3TS?

It accepts 0.34…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, with 1.2 mm (3/64 in.) insulation max.

What are the dimensions of the 1794-TB3TS?

Dimensions (HxWxD) are 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in).

What operating temperature range and wiring category apply to the 1794-TB3TS?

Operating temperature is -20…+70 °C (-4…+158 °F) and the wiring category is 2.

Wire size (common terminal base characteristic)
0.34…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater; 1.2 mm (3/64 in.) insulation max
Dimensions (HxWxD) (common terminal base characteristic)
94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in)
Termination type
Spring clamp, temperature
Connections
16 I/O; 10 common; 4 +V; 8 chassis ground; 2 sets of CJC for temperature modules
Used in applications
Up to 132V AC/156V DC
Wiring category
2
Purpose
A spring clamp version of the 1794-TB3T
Temperature, operating
-20…+70 °C (-4…+158 °F)

Technical specifications are based on the linked manufacturer reference.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp