Omron 3G3MX2-A2004-E inverter for three-phase 200 V class supply.
Applicable motor capacity: CT 0.4 kW / VT 0.75 kW.
Rated output current: CT 3.0 A / VT 3.5 A.
Rated output capacity: CT 1.0 kVA / VT 1.2 kVA at 200 V, and CT 1.2 kVA / VT 1.4 kVA at 240 V.
Output frequency range 0.1 to 400 Hz; starting torque 200% at 0.5 Hz; enclosure rating IP 20. This starting-torque figure applies at rated voltage with a standard three-phase, four-pole motor under sensorless vector control.
| Applicable motor capacity, CT/VT | CT 0.4 kW / VT 0.75 kW |
|---|---|
| Rated output capacity at200V, CT/VT | CT 1.0 kVA / VT 1.2 kVA |
| Rated output capacity at240V, CT/VT | CT 1.2 kVA / VT 1.4 kVA |
| Rated output current, CT/VT | CT 3.0 A / VT 3.5 A |
| Rated input supply | Three-phase: 200 V-15% to 240 V+10%, 50/60 Hz±5% |
| Starting torque with specified motor/control conditions | 200% at 0.5 Hz (at rated voltage with a standard three-phase, four-pole motor under sensorless vector control) |
| Device mass | 1.1 kg |
| Output frequency range | 0.1 to 400 Hz |
| Enclosure rating | IP 20 |
| Device dimensions (W x H x D) | 68 × 128 × 122.5 mm |
The applicable motor capacity is CT 0.4 kW / VT 0.75 kW, so the rating depends on whether heavy-duty (CT) or variable-torque (VT) operation applies.
It is rated for three-phase 200 V-15% to 240 V+10%, 50/60 Hz±5%.
Rated output current is CT 3.0 A / VT 3.5 A. Rated output capacity is CT 1.0 kVA / VT 1.2 kVA at 200 V and CT 1.2 kVA / VT 1.4 kVA at 240 V.
The output frequency range is 0.1 to 400 Hz, and starting torque is 200% at 0.5 Hz. This starting-torque figure applies at rated voltage with a standard three-phase, four-pole motor under sensorless vector control.
The enclosure rating is IP 20, and the device dimensions are 68 × 128 × 122.5 mm (W x H x D).
The applicable motor capacity is CT 0.4 kW / VT 0.75 kW, so the rating depends on whether heavy-duty (CT) or variable-torque (VT) operation applies.
It is rated for three-phase 200 V-15% to 240 V+10%, 50/60 Hz±5%.
Rated output current is CT 3.0 A / VT 3.5 A. Rated output capacity is CT 1.0 kVA / VT 1.2 kVA at 200 V and CT 1.2 kVA / VT 1.4 kVA at 240 V.
The output frequency range is 0.1 to 400 Hz, and starting torque is 200% at 0.5 Hz. This starting-torque figure applies at rated voltage with a standard three-phase, four-pole motor under sensorless vector control.
The enclosure rating is IP 20, and the device dimensions are 68 × 128 × 122.5 mm (W x H x D).
Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.