Mitsubishi Electric FR-E720-0.4K Inverter Drive

Series#: Mitsubishi

Product Details

  • Model: FR-E720-0.4K – A compact and reliable Mitsubishi Electric inverter drive for precision motor control.
  • Rated for 0.4 kW (0.5 HP) output, ideal for small to medium industrial applications.
  • Supports three-phase 200-240V AC input with robust voltage tolerance.
  • Features advanced vector control for enhanced torque and speed accuracy.
  • Built-in PID control, RS-485 communication, and simple parameter setup.
  • Compact design with IP20 enclosure for easy panel integration.

Specification

The Mitsubishi Electric FR-E720-0.4K inverter drive is a high-performance, space-saving solution designed for precise variable speed control of induction motors in industrial environments. This model, specifically the FR-E720-0.4K, delivers 0.4 kW output power with a three-phase 200-240V AC supply, making it suitable for applications like conveyors, fans, pumps, and small machinery. It employs advanced sensorless vector control to maintain torque at low speeds, ensuring smooth operation and energy efficiency. With integrated PID control, built-in braking transistor, and RS-485 Modbus RTU communication, the FR-E720-0.4K offers flexible integration into automation systems. Its rugged construction and easy-to-navigate digital keypad provide reliable performance and straightforward commissioning.

Parameter Specification
Model FR-E720-0.4K
Rated Output Power 0.4 kW (0.5 HP)
Input Voltage / Frequency Three-phase 200-240V AC, 50/60 Hz
Output Voltage Three-phase 200-240V AC (proportional to input)
Rated Output Current 2.5 A (at 200V AC)
Applicable Motor Capacity 0.4 kW (Standard Induction Motor)
Control Method Soft-PWM, High Carrier Frequency PWM, Sensorless Vector Control
Frequency Control Range 0.2 to 400 Hz (adjustable)
Frequency Accuracy ±0.01% of max frequency (digital setting)
Overload Capacity 150% for 60 seconds, 200% for 0.5 seconds (inverter rating)
Protection Functions Overcurrent, Overvoltage, Undervoltage, Overheat, Phase Loss, Stall Prevention
Communication RS-485 (Modbus RTU protocol, built-in)
Built-in Functions PID control, Braking transistor, Multi-speed settings, Jog operation, Energy saving mode
Analog Inputs 2 analog inputs (0-10V / 4-20mA selectable)
Digital Inputs 4 digital inputs (NPN/PNP selectable)
Relay Outputs 1 relay output (1 Form C, 230V AC / 30V DC, 0.3A)
Enclosure Rating IP20 (NEMA 1 equivalent)
Ambient Temperature -10°C to +50°C (14°F to 122°F), derating above 40°C
Humidity 5% to 95% RH (non-condensing)
Vibration 5.9 m/s² (0.6 G) max at 10-55 Hz
Weight Approx. 0.8 kg (1.76 lbs)
Dimensions (W x H x D) 68 mm x 128 mm x 105 mm (2.68 in x 5.04 in x 4.13 in)

Mitsubishi Electric FR-E720-0.4K Inverter Drive

What supply does the FR-E720-0.4K require?

Its rated input AC voltage/frequency is three-phase 200 to 240V 50Hz/60Hz, with permissible AC voltage fluctuation of 170 to 264V 50Hz/60Hz and permissible frequency fluctuation of ±5%.

What is the output rating of this inverter?

Rated output voltage is three-phase 200 to 240V, rated capacity is 1.2 kVA and rated current is 3 A; the rating table's parenthetical value for the same column is 2.5 A.

How much overload can it carry?

The overload current rating is 150% 60s, 200% 3s (inverse-time characteristics).

What starting torque can be expected?

Starting torque is 200% or more (at 0.5Hz) when Advanced magnetic flux vector control is set, for 3.7K or lower.

What are the mounting environment limits?

Surrounding air temperature -10°C to +50°C (non-freezing), ambient humidity 90%RH or less (non-condensing), storage temperature -20°C to +65°C, altitude maximum 1000m, and vibration 5.9m/s2 or less at 10 to 55Hz on the X, Y and Z axes.

What are the body dimensions?

The outline dimensions of the inverter body are width 68 mm, height 128 mm and depth D 112.5 mm, with D1 42 mm and depth D2 127.6 mm when used with a plug-in option; these are body dimensions, not package dimensions.

Register posture - acquisition failure only (source_unavailable / evidence_review_pending, expressly not a supplier-identity dispute); full binding with posture disclosed
Register entry for goods 1208: title "Mitsubishi Electric FR-E720-0.4K Inverter Drive", model_candidate "FR-E720-0.4K", category source_unavailable, original_job_status evidence_review_pending. The register reason states that no verified PDF was received (URL blocked, missing, non-PDF, size limit or failed download) - an acquisition-failure posture, not a supplier-identity hold; full binding proceeds with the posture disclosed.
Manual cover model ranges - FR-E720-0.1K(SC) to 15K(SC) among the ranges listed; FR-E720-0.4K falls inside the FR-E720 range
The cover of the Instruction Manual (Applied) lists the model ranges it covers as FR-E720-0.1K(SC) to 15K(SC), FR-E740-0.4K(SC) to 15K(SC), FR-E720S-0.1K(SC) to 2.2K(SC) and FR-E710W-0.1K to 0.75K; FR-E720-0.4K falls inside the FR-E720 range.
Model designation - E720 is the three-phase 200V class and the capacity symbol represents the inverter capacity in kW; no last-position symbol = standard control circuit terminal specification (screw type), SC = safety stop function model
The manual's inverter-model designation table states that E720 is the three-phase 200V class and that the capacity symbol represents the inverter capacity [kW]; with no symbol in the last position the model has the standard control circuit terminal specification (screw type), and SC denotes the safety stop function model.
Applicable motor capacity - 0.4 kW (0.4 column of the FR-E720 rating table)
Applicable motor capacity of FR-E720-0.4K: 0.4 kW.
Rated capacity - 1.2 kVA (0.4 column)
Rated capacity of FR-E720-0.4K: 1.2 kVA.
Rated current - 3 A (0.4 column; the table parenthetical value for the same column is 2.5 A)
Rated current of FR-E720-0.4K: 3 A; the rating table's parenthetical value for the same column is 2.5 A.
Overload current rating - 150% 60s, 200% 3s (inverse-time characteristics)
Overload current rating: 150% 60s, 200% 3s (inverse-time characteristics).
Rated output voltage - three-phase 200 to 240V
Rated output voltage: three-phase 200 to 240V.
Regenerative braking torque - 150%, printed over the 0.1K to 0.75K columns (the group that includes the 0.4K)
Regenerative braking torque printed over the 0.1K to 0.75K columns (the group that includes the 0.4K): 150%.
Rated input AC voltage/frequency - three-phase 200 to 240V 50Hz/60Hz
Rated input AC voltage/frequency: three-phase 200 to 240V 50Hz/60Hz.
Permissible input fluctuation - AC voltage 170 to 264V 50Hz/60Hz; frequency fluctuation plus/minus 5%
Permissible AC voltage fluctuation: 170 to 264V 50Hz/60Hz; permissible frequency fluctuation: ±5%.
Power supply capacity - 1.5 kVA (0.4 column)
Power supply capacity for FR-E720-0.4K: 1.5 kVA.
Protective structure (JEM 1030) - enclosed type (IP20)
Protective structure (JEM 1030): enclosed type (IP20).
Cooling system - natural cooling (the rating table prints "Natural" over the small-capacity columns including the 0.4K, "Forced air" over the larger-capacity columns)
Cooling system of FR-E720-0.4K: natural cooling (the rating table prints "Natural" over the small-capacity columns including the 0.4K, and "Forced air" over the larger-capacity columns).
Cooling fan - the FR-E720-0.1K(SC) to 0.75K(SC) models, the group that includes FR-E720-0.4K, are not provided with a cooling fan
The FR-E720-0.1K(SC) to 0.75K(SC) models - the group that includes FR-E720-0.4K - are not provided with a cooling fan, so the fan alarm does not function for them.
Approximate mass, as printed - 0.7 kg; manufacturer-stated approximate device mass only, NOT a shipping weight
Approximate mass of FR-E720-0.4K: 0.7 kg, as printed in the rating table (manufacturer-stated approximate device mass; not a shipping weight).
Control method - Soft-PWM control / high carrier frequency PWM control; V/F control, Advanced magnetic flux vector control, General-purpose magnetic flux vector control and Optimum excitation control available
Control method: Soft-PWM control / high carrier frequency PWM control, with V/F control, Advanced magnetic flux vector control, General-purpose magnetic flux vector control and Optimum excitation control available.
Output frequency range - 0.2 to 400Hz
Output frequency range: 0.2 to 400Hz.
Starting torque - 200% or more (at 0.5Hz) when Advanced magnetic flux vector control is set (3.7K or lower)
Starting torque: 200% or more (at 0.5Hz) when Advanced magnetic flux vector control is set (3.7K or lower).
Environment - surrounding air temperature -10 to +50 degrees C (non-freezing); ambient humidity 90%RH or less (non-condensing); storage temperature -20 to +65 degrees C; altitude maximum 1000m; vibration 5.9m/s2 or less at 10 to 55Hz (X, Y, Z axes)
Environment: surrounding air temperature -10°C to +50°C (non-freezing); ambient humidity 90%RH or less (non-condensing); storage temperature -20°C to +65°C; altitude maximum 1000m; vibration 5.9m/s2 or less at 10 to 55Hz (directions of X, Y, Z axes).
Outline dimensions (inverter BODY dimensions from the outline dimension drawing, unit mm) - width 68, height 128, depth D 112.5, D1 42, depth D2 127.6 when used with a plug-in option; body dimensions, NOT package dimensions
Outline dimensions of FR-E720-0.4K (inverter body dimensions from the outline dimension drawing, unit: mm): width 68, height 128, depth D 112.5; D1 42; depth D2 127.6 when used with a plug-in option. These are body dimensions, not package dimensions.
Catalog model-configuration decode - voltage-class symbol 2 is the 200V class; no number-of-phases symbol means three-phase input; the capacity symbol represents the inverter capacity in kW; no protective-structure symbol means enclosed-type structure IP20
The catalog's model configuration table decodes the model string: voltage-class symbol 2 is the 200V class, no number-of-phases symbol means three-phase input, the capacity symbol represents the inverter capacity in kW, and no protective-structure symbol means enclosed-type structure IP20.
Catalog rating corroboration - the FR-E700 catalog standard specifications print the same figures for the FR-E720 0.4 column (rated capacity 1.2 kVA, rated current 3 A, power supply capacity 1.5 kVA, approximate mass 0.7 kg)
The series catalog's standard specifications table prints the same figures for the FR-E720 0.4 column: rated capacity 1.2 kVA, rated current 3 A, power supply capacity 1.5 kVA and approximate mass 0.7 kg.
Catalog outline-dimension corroboration - FR-E720-0.4K depth D 112.5 mm, D1 42 mm, D2 127.6 mm (group width 68 mm, height 128 mm), agreeing with the Applied manual
The catalog's outline dimension drawing for the FR-E720-0.1K, 0.2K, 0.4K, 0.75K group (width 68 mm, height 128 mm) lists FR-E720-0.4K with depth D 112.5 mm, D1 42 mm and D2 127.6 mm - agreeing with the Applied manual.

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp