Delta VFD110C43A Inverter

Series#: Delta

Product Details

  • Delta Inverters C2000 Series 11kW VFD110C43A 380V – high-performance vector control drive for industrial automation.
  • Rated output: 11kW (15HP) at 380V three-phase input, ideal for pumps, fans, conveyors, and machine tools.
  • Advanced sensorless vector control (SLV) and closed-loop vector control (FOC) for precise torque and speed regulation.
  • Built-in PLC function, multi-pump control, and fieldbus communication options (Modbus, CANopen, Profibus).
  • Robust design with IP20 enclosure, built-in EMC filter, and overload capacity up to 150% for 60 seconds.

Specification

The Delta Inverters C2000 Series VFD110C43A 380V is a compact yet powerful 11kW variable frequency drive engineered for demanding industrial applications. This model leverages Delta’s proprietary vector control algorithms to deliver exceptional motor performance, energy savings, and reliability. The VFD110C43A supports both induction and permanent magnet motors, making it a versatile choice for retrofitting existing systems or integrating into new automation lines. With built-in PID control, programmable digital and analog I/O, and support for multiple communication protocols, it simplifies system integration while reducing downtime. Whether controlling a conveyor belt, a centrifugal pump, or a high-speed spindle, the C2000 ensures smooth operation and precise process control.

Parameter Specification
Model Number VFD110C43A
Series Delta C2000
Rated Power 11 kW (15 HP)
Input Voltage 3-Phase 380VAC, 50/60 Hz (±10%)
Output Voltage 3-Phase 0-380VAC (adjustable)
Rated Output Current 25 A
Control Method V/F, Sensorless Vector (SLV), Closed-Loop Vector (FOC)
Frequency Range 0.00 – 599.00 Hz (resolution 0.01 Hz)
Overload Capacity 150% for 60 seconds; 200% for 3 seconds
Braking Torque 20% without braking unit; up to 125% with optional braking resistor
Digital Inputs 6 programmable NPN/PNP
Digital Outputs 3 programmable (2 relay + 1 open collector)
Analog Inputs 2 (0-10V / 4-20mA selectable)
Analog Outputs 2 (0-10V / 4-20mA selectable)
Built-in PLC Yes, with ladder logic programming (max 500 steps)
Communication Protocols Modbus RTU (standard), CANopen (optional), Profibus-DP (optional)
Protection Features Overcurrent, overvoltage, undervoltage, overtemperature, phase loss, motor overload
Enclosure Rating IP20
Ambient Temperature -10°C to +50°C (derate above 40°C)
Dimensions (W x H x D) Approx. 180 mm x 300 mm x 200 mm
Weight Approx. 4.5 kg
Certifications CE, UL, cUL, RoHS

Delta VFD110C43A Inverter

What motor size is this drive rated for?

The 110 column of the 460V series specification table gives an applicable motor output of 11 kW (15 hp).

What are the Heavy Duty and Normal Duty output ratings?

Heavy Duty rated output capacity is 18 kVA with 23 A rated output current; Normal Duty rated output capacity is 19 kVA with 24 A rated output current.

What input current does it draw?

Input current is 25 A under Heavy Duty and 26 A under Normal Duty, per the 110 column.

What supply voltage and frequency can it accept?

The rated input is 3-phase AC 380V~480V (-15%~+10%) at 50/60 Hz, with an operating voltage range of 323~528 Vac and frequency tolerance of 47~63 Hz.

Does this version include an EMI filter?

No. As printed, VFDXXXC43A has no EMI filter, while VFDXXXC43E has a built-in EMI filter; this record is the A version.

What enclosure protection level applies?

Per the manual note, for Frame A, B and C, model VFDXXXC43A is under IP20 / NEMA1 / UL TYPE1 protection level.

Register posture (evidence-pending caution — disclosed, full binding)
Register category exact_model_mapping_unverified, original_job_status evidence_review_pending; reason recorded verbatim in the quote. Judged by its reason text (the standing method), the text records an order-number applicability caution on a previously received document - it asserts no supplier-identity dispute and no supplier-confirmation request, and the register itself attests the exact model via an explicit model_candidate identical to the catalog model string. It is therefore the evidence-pending class, NOT the formal supplier-identity hold class. Full binding on the genuine Delta user manual for the series, which attests the model string verbatim, posture disclosed.
Frame membership (Frame B model list)
The manual's Frame B group lists VFD110C43A/E - the model is a Frame B unit of the series.
Applicable motor output (460V series table, 110 column)
Applicable motor output 11 kW (15 hp) - the 110 column of the 460V series specification table.
Heavy Duty rated output (460V series table, 110 column)
Heavy Duty rated output capacity 18 kVA, rated output current 23 A (110 column).
Normal Duty rated output (460V series table, 110 column)
Normal Duty rated output capacity 19 kVA, rated output current 24 A (110 column).
Input current (460V series table, 110 column)
Input current 25 A (Heavy Duty) / 26 A (Normal Duty) - 110 column.
Input rating (460V series table)
Rated voltage / frequency: 3-phase AC 380V~480V (-15%~+10%), 50/60 Hz; operating voltage range 323~528 Vac; frequency tolerance 47~63 Hz.
Frame B (B1) dimensions (device dimensions as printed)
Frame B (B1) dimensions in mm [inch]: W 190.0 [7.48], H 320.0 [12.60], D 190.0 [7.48]; mounting W1 173.0 [6.81], H1 303.0 [11.93]. Device dimensions as printed; package dimensions are not printed (GAP).
Braking chopper / DC reactor (460V series table)
Braking chopper: built-in. DC reactor: option (as printed for the Frames A-C specification group of this table).
EMI filter by version type (460V series table)
EMI filter by version type as printed: VFDXXXC43A has no EMI filter; VFDXXXC43E has a built-in EMI filter. This record is the A version, so no EMI filter.
Protection level (manual NOTE after the 460V tables)
For Frame A, B and C, model VFDXXXC43A is under IP20 / NEMA1 / UL TYPE1 protection level (manual NOTE).
Airflow / power dissipation (VFD110C43A/E row)
Air flow rate for cooling (VFD110C43A/E row): total 80 cfm (136 m3/hr). Power dissipation of the AC motor drive: total 380 W - internal 287 W, external (heat sink) 93 W.

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp