MR-J4-10A Procurement Questions
Which rotary servo motors can be combined with the MR-J4-10A?
The 200 V class combinations table lists HG-KR053, HG-KR13, HG-MR053 and HG-MR13 for the MR-J4-10A(-RJ) row.
Can the MR-J4-10A be used with a fully closed loop system and a four-wire external encoder?
Fully closed loop control is listed as compatible, but the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later; four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector. The MR-J4-_A servo amplifier is compatible only with the two-wire type.
What input pulse frequency does the MR-J4-10A accept, and is a parameter change needed?
Max. input pulse frequency is 4 Mpulses/s for differential receiver and 200 kpulses/s for open collector. 1 Mpulse/s or lower commands are supported in the initial setting; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13].
What are the permissible voltage and frequency fluctuations for the main circuit input?
Permissible voltage fluctuation is 3-phase or 1-phase 170 V AC to 264 V AC, and permissible frequency fluctuation is within ±5%.
Is the STO safety level unconditional on the MR-J4-10A?
STO is listed under IEC/EN 61800-5-2 with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2, but the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.
What ambient temperature range applies when closely mounting the MR-J4-10A?
Close mounting is allowed on 3-phase and 1-phase supply; when closely mounting the servo amplifiers, operate them at the ambient temperature of 0 °C to 45 °C or at 75% or smaller effective load ratio.
- Model identity
- MR-J4-10A: MR-J4 series servo amplifier, general-purpose interface; capacity symbol 10 = 0.1 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class)
- Output
- Rated voltage 3-phase 170 V AC; rated current 1.1 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.9 A (1.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.5 A (including the CN8 connector signals) (Note 1: 0.5 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 9: for the compatible version for the fully closed loop system, refer to Table 1.1 — printed p.1-2; the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later; four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_A servo amplifier is compatible only with the two-wire type (Note 10)
- Position control mode
- Max. input pulse frequency: 4 Mpulses/s (for differential receiver), 200 kpulses/s (for open collector); positioning feedback pulse: encoder resolution 22 bits (resolution per servo motor revolution) (Note 6: 1 Mpulse/s or lower commands are supported in the initial setting; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13])
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 15: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Natural cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 16): follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase and 1-phase supply; operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 0.8 kg (the Mass row prints one value for the 10A and 20A columns together)
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-KR053, HG-KR13, HG-MR053, HG-MR13
Technical specifications follow the cited manufacturer references.
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22