MR-J4-70A Procurement Questions
What is the difference between the main circuit and control circuit power supply inputs on the MR-J4-70A?
The main circuit input accepts 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz, with a rated current of 3.8 A (6.5 A with 1-phase power supply input), permissible voltage fluctuation of 3-phase or 1-phase 170 V AC to 264 V AC, and permissible frequency fluctuation within ±5%. The control circuit input is separate: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz, 0.2 A rated current, 30 W power consumption, permissible voltage fluctuation 1-phase 170 V AC to 264 V AC, and permissible frequency fluctuation within ±5%.
Can the MR-J4-70A run a fully closed loop system with a four-wire encoder?
Fully closed loop control is listed as compatible, but the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later. Four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector; the MR-J4-_A_ servo amplifier is compatible only with the two-wire type.
What pulse frequency can the MR-J4-70A accept in position control mode?
Max. input pulse frequency is 4 Mpulses/s for differential receiver and 200 kpulses/s for open collector. In the initial setting, commands of 1 Mpulse/s or lower are supported; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13].
What does the STO safety level of the MR-J4-70A depend on?
The amplifier provides STO (IEC/EN 61800-5-2) with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.
Which rotary servo motors are listed as combinations for the MR-J4-70A?
The 200 V class combinations table lists HG-KR73, HG-MR73, HG-UR72 and HG-JR73 for the MR-J4-70A(-RJ) row.
Which linear and direct drive motors are listed for the MR-J4-70A, and is there a software version condition?
Linear servo motors (primary side): LM-H3P3B-24P-CSS0, LM-H3P3C-36P-CSS0, LM-H3P7A-24P-ASS0, LM-K2P2A-02M-1SS1, LM-U2PBF-22M-1SS0; direct drive motors: TM-RFM012E20, TM-RFM012G20, TM-RFM040J10. These combinations are available with servo amplifiers with software version A5 or later.
- Model identity
- MR-J4-70A: MR-J4 series servo amplifier, general-purpose interface; capacity symbol 70 = 0.75 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class)
- Output
- Rated voltage 3-phase 170 V AC; rated current 5.8 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 3.8 A (6.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.5 A (including the CN8 connector signals) (Note 1: 0.5 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 9: for the compatible version for the fully closed loop system, refer to Table 1.1 — printed p.1-2; the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later; four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_A servo amplifier is compatible only with the two-wire type (Note 10)
- Position control mode
- Max. input pulse frequency: 4 Mpulses/s (for differential receiver), 200 kpulses/s (for open collector); positioning feedback pulse: encoder resolution 22 bits (resolution per servo motor revolution) (Note 6: 1 Mpulse/s or lower commands are supported in the initial setting; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13])
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 15: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Force cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 16): follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase and 1-phase supply; operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 1.4 kg (the Mass row prints one value for the 70A and 100A columns together)
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-KR73, HG-MR73, HG-UR72, HG-JR73
- Combinations — linear / direct drive motors
- Combinations (200 V class combinations table): linear servo motors (primary side): LM-H3P3B-24P-CSS0, LM-H3P3C-36P-CSS0, LM-H3P7A-24P-ASS0, LM-K2P2A-02M-1SS1, LM-U2PBF-22M-1SS0; direct drive motors: TM-RFM012E20, TM-RFM012G20, TM-RFM040J10 (Note 1: these combinations are available with servo amplifiers with software version A5 or later)
Technical specifications follow the cited manufacturer references.
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22