MR-J4-500A Procurement Questions
What is the difference between the main circuit and control circuit power supply requirements for the MR-J4-500A?
The main circuit input is 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz with 21.7 A rated current and permissible voltage fluctuation of 3-phase 170 V AC to 264 V AC. The control circuit input is separate: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz, 0.3 A, 45 W, with permissible voltage fluctuation of 1-phase 170 V AC to 264 V AC. Both have a permissible frequency fluctuation of within ±5%.
Can the MR-J4-500A run a fully closed loop system with a four-wire encoder?
The MR-J4-500A supports fully closed loop control, but the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later. Four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector, so those encoder types are not supported on this plain model.
What input pulse frequency can the MR-J4-500A accept, and is a parameter change needed?
The maximum input pulse frequency is 4 Mpulses/s for differential receiver and 200 kpulses/s for open collector. In the initial setting, commands of 1 Mpulse/s or lower are supported; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13].
What does the STO safety level of the MR-J4-500A depend on?
The amplifier provides STO (IEC/EN 61800-5-2) with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.
Which rotary servo motors are listed as combinations for the MR-J4-500A?
The 200 V class combinations table lists HG-SR421, HG-SR502, HG-UR352, HG-UR502, HG-RR353, HG-RR503, HG-JR353 and HG-JR503. Of these, HG-JR353 carries the table's Note 3 marker, meaning the combination increases the maximum torque of the servo motor to 400%.
Can the MR-J4-500A be close mounted, and what are the ambient limits?
Close mounting is not allowed on 3-phase supply and is not applicable on 1-phase supply, and this model is 3-phase only. Ambient temperature is 0 °C to 55 °C for operation (non-freezing) and -20 °C to 65 °C for storage (non-freezing); ambient humidity is 5 %RH to 90 %RH (non-condensing); altitude is 2000 m or less above sea level, and at altitude exceeding 1000 m and up to 2000 m the restrictions in section 2.6 apply.
- Model identity
- MR-J4-500A: MR-J4 series servo amplifier, general-purpose interface; capacity symbol 500 = 5 kW rated output; no power-supply symbol = 3-phase 200 V AC to 240 V AC (200 V class)
- Output
- Rated voltage 3-phase 170 V AC; rated current 28.0 A
- Main circuit power supply input
- Voltage/frequency: 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 21.7 A; permissible voltage fluctuation: 3-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.3 A; power consumption 45 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.5 A (including the CN8 connector signals) (Note 1: 0.5 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 9: for the compatible version for the fully closed loop system, refer to Table 1.1 — printed p.1-2; the MR-J4-_A_ connects a two-wire type external encoder to CN2, used with software version A5 or later; four-wire type and A/B/Z-phase differential output method require the MR-J4-_A_-RJ CN2L connector); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_A servo amplifier is compatible only with the two-wire type (Note 10)
- Position control mode
- Max. input pulse frequency: 4 Mpulses/s (for differential receiver), 200 kpulses/s (for open collector); positioning feedback pulse: encoder resolution 22 bits (resolution per servo motor revolution) (Note 6: 1 Mpulse/s or lower commands are supported in the initial setting; when inputting differential-receiver commands over 1 Mpulse/s and 4 Mpulses/s or lower, change the setting in [Pr. PA13])
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 15: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Force cooling, open (IP20); Note 4: Except for the terminal block.
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 16): follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): not allowed on 3-phase supply; not applicable on 1-phase supply (this model is 3-phase only)
- Device mass
- 4.0 kg
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-SR421, HG-SR502, HG-UR352, HG-UR502, HG-RR353, HG-RR503, HG-JR353, HG-JR503; of these, HG-JR353 carry the table's Note 3 marker (the combination increases the maximum torque of the servo motor to 400%)
- Combinations — linear / direct drive motors
- Combinations (200 V class combinations table): linear servo motors (primary side): LM-FP2D-12M-1SS0, LM-FP4B-12M-1SS0, LM-K2P2E-12M-1SS1, LM-K2P3E-24M-1SS1, LM-U2P2D-80M-2SS0; direct drive motors: TM-RFM240J10 (Note 1: these combinations are available with servo amplifiers with software version A5 or later)
Technical specifications follow the cited manufacturer references.