MR-J4-10B Procurement Questions
Which servo motors can be combined with the MR-J4-10B?
The 200 V class combinations table lists HG-KR053, HG-KR13, HG-MR053 and HG-MR13 for the MR-J4-10B(-RJ) row.
Can the MR-J4-10B be used with a four-wire type load-side encoder?
No. The MR-J4-_B_ servo amplifier is compatible only with the two-wire type; for a four-wire type servo motor encoder, MR-J4-_B_ cannot be used and an MR-J4-_B_-RJ is required. Two-wire type connects to CN2, with software version A3 or later for the fully closed loop system and A8 or later for the scale measurement function.
What interface power supply does the MR-J4-10B require?
24 V DC ± 10% with a current capacity of 0.3 A (including the CN8 connector signals). Note 1 states that 0.3 A applies when all I/O signals are used, and the current capacity can be decreased by reducing the number of I/O points.
Are all three listed SSCNET III/H communication cycles selectable?
The listed cycles are 0.222 ms, 0.444 ms and 0.888 ms, but Note 8 states that the communication cycle depends on the controller specifications and the number of axes connected, so not all listed values are selectable under any configuration.
Is the functional safety level of the MR-J4-10B unconditional?
The amplifier supports STO (IEC/EN 61800-5-2) with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. Note 14 states that the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.
What ambient conditions apply when closely mounting the MR-J4-10B?
Close mounting is allowed on both 3-phase and 1-phase supply for this model. When closely mounting the servo amplifiers, operate them at the ambient temperature of 0 °C to 45 °C or at 75% or smaller effective load ratio.
- Model identity
- MR-J4-10B: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 10 = 0.1 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class)
- Output
- Rated voltage 3-phase 170 V AC; rated current 1.1 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.9 A (1.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B servo amplifier is compatible only with two-wire type (Note 5) (Table 1.1, printed p.1-2: fully closed loop system and scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 4 for fully closed loop; Notes 2, 3, 5 for scale measurement); four-wire type and A/B/Z-phase differential output method — MR-J4-_B_ cannot be used, use an MR-J4-_B_-RJ (Note 3); software version A3 or later (Note 4) / A8 or later (Note 5))
- SSCNET III/H communication cycle
- SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Natural cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase and 1-phase supply; operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 0.8 kg (the Mass row prints one value for the 10B and 20B columns together)
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-KR053, HG-KR13, HG-MR053, HG-MR13