Mitsubishi Electric MR-J4-100B-RJ Servo Amplifier

Series#: Mitsubishi

Product Details

  • Mitsubishi Electric MR-J4-100B-RJ Servo Amplifier
  • Command interface: SSCNET III/H
  • Main circuit supply: Single-phase or three-phase 200–240 V AC, 50/60 Hz
  • Rated output voltage: Three-phase 170 V AC
  • Rated output current: 6.0 A

Specification

Mitsubishi Electric MR-J4-100B-RJ — Servo Amplifier.

Technical Specifications

SpecificationDetails
ManufacturerMitsubishi Electric
Catalog numberMR-J4-100B-RJ
Command interfaceSSCNET III/H
Main circuit supplySingle-phase or three-phase 200–240 V AC, 50/60 Hz
Rated output voltageThree-phase 170 V AC
Rated output current6.0 A
Controlled axes1
Manufacturer weight reference1.4 kg — Manufacturer product mass; packaging inclusion not specified
Mitsubishi Electric — MELSERVO-J4 catalog L(NA)03058ENG-J, PDF pages 101, 102

MR-J4-100B-RJ Procurement Questions

Can this amplifier run on a single-phase 200 V AC supply, and what limitation applies?

Yes. The main circuit accepts 3-phase or 1-phase 200 V AC to 240 V AC at 50 Hz/60 Hz, and the rated current is 5.0 A, or 10.5 A with 1-phase power supply input. When using a 1-phase 200 V AC to 240 V AC power supply, the servo amplifier must be operated at 75% or smaller effective load ratio.

Which load-side encoder connection types does the -RJ variant support, and on which connectors?

The MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type and A/B/Z-phase differential output method. In a fully closed loop system the two-wire type connects to CN2, while the four-wire type and A/B/Z-phase differential output method connect to CN2L; for the scale measurement function the four-wire type and A/B/Z-phase differential output method connect to CN2L and require software version A8 or later.

What safety level does the STO function provide?

The functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and on whether STO input diagnosis by TOFB output is performed.

Can this amplifier be mounted closely against another unit?

Close mounting is allowed on 3-phase supply only and not allowed on 1-phase supply. When closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio.

Which rotary servo motors are listed as combinations for this amplifier, and does the 400% maximum torque apply on a 1-phase supply?

The listed rotary combinations are HG-SR81, HG-SR102, HG-JR53 and HG-JR103, of which HG-JR53 carries the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%). When a 1-phase 200 V AC input is used, the maximum torque of 400% cannot be achieved with HG-JR series servo motors, and for the torque characteristics of the HG-UR, HG-RR and HG-JR series with 1-phase 200 V AC input you should contact your local sales office.

Does this -RJ model accept a DC power supply input?

DC power supply input is available only with MR-J4-_B-RJ servo amplifiers. The main circuit and control circuit DC input is 283 V DC to 340 V DC, with permissible voltage fluctuation of 241 V DC to 374 V DC; for parameter setting values when a DC input is used, refer to the Function column of [Pr. PC20] in section 5.2.3.

Model identity
MR-J4-100B-RJ: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 100 = 1 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class) (Note 13: when using a single-phase supply, effective load rate 75% or smaller); -RJ = fully closed loop control four-wire type/load-side encoder A/B/Z-phase input compatible/Compatible with MR-D30 functional safety unit
Output
Rated voltage 3-phase 170 V AC; rated current 6.0 A
Main circuit power supply input
Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz (Note 13: when using a single-phase supply, effective load rate 75% or smaller); rated current 5.0 A (10.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Control circuit power supply input
Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Interface power supply
24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
Control method / dynamic brake
Sine-wave PWM control, current control method; dynamic brake: Built-in
Fully closed loop control / load-side encoder interface
Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type, and A/B/Z-phase differential output method (Note 5) (Table 1.1, printed p.1-2: fully closed loop system — two-wire type connects to CN2 (Notes 2, 3, 4); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 6: connect a thermistor to CN2); scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 5); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 5: software version A8 or later))
SSCNET III/H communication cycle
SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
Functional safety
STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
Structure (IP rating) / cooling
Force cooling, open (IP20)
Environment
Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase supply only, not allowed on 1-phase supply; when closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
Device mass
1.4 kg (the Mass row prints one value for the 100B and 70B columns together)
Combinations — rotary servo motors
Combinations with rotary servo motors (200 V class combinations table): HG-SR81, HG-SR102, HG-JR53, HG-JR103; of these, HG-JR53 carry the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%); POINT (§1.4, PDF p.36): when a 1-phase 200 V AC input is used, the maximum torque of 400% cannot be achieved with HG-JR series servo motor; when using the MR-J4-100B(-RJ) or MR-J4-200B(-RJ) with the 1-phase 200 V AC input, contact your local sales office for the torque characteristics of the HG-UR series, HG-RR series, and HG-JR series servo motors
Combinations — linear / direct drive motors
Combinations (200 V class combinations table): direct drive motors: TM-RFM018E20
DC power supply input (-RJ only)
DC power supply input is available only with MR-J4-_B-RJ servo amplifiers (Note 16): main circuit input 283 V DC to 340 V DC; control circuit input 283 V DC to 340 V DC; permissible voltage fluctuation: 241 V DC to 374 V DC (main circuit and control circuit); parameter setting values for DC input: refer to the Function column of [Pr. PC20] in section 5.2.3 (Note 16)

Technical specifications follow the cited manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp