MR-J4-100B-RJ Procurement Questions
Can this amplifier run on a single-phase 200 V AC supply, and what limitation applies?
Yes. The main circuit accepts 3-phase or 1-phase 200 V AC to 240 V AC at 50 Hz/60 Hz, and the rated current is 5.0 A, or 10.5 A with 1-phase power supply input. When using a 1-phase 200 V AC to 240 V AC power supply, the servo amplifier must be operated at 75% or smaller effective load ratio.
Which load-side encoder connection types does the -RJ variant support, and on which connectors?
The MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type and A/B/Z-phase differential output method. In a fully closed loop system the two-wire type connects to CN2, while the four-wire type and A/B/Z-phase differential output method connect to CN2L; for the scale measurement function the four-wire type and A/B/Z-phase differential output method connect to CN2L and require software version A8 or later.
What safety level does the STO function provide?
The functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and on whether STO input diagnosis by TOFB output is performed.
Can this amplifier be mounted closely against another unit?
Close mounting is allowed on 3-phase supply only and not allowed on 1-phase supply. When closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio.
Which rotary servo motors are listed as combinations for this amplifier, and does the 400% maximum torque apply on a 1-phase supply?
The listed rotary combinations are HG-SR81, HG-SR102, HG-JR53 and HG-JR103, of which HG-JR53 carries the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%). When a 1-phase 200 V AC input is used, the maximum torque of 400% cannot be achieved with HG-JR series servo motors, and for the torque characteristics of the HG-UR, HG-RR and HG-JR series with 1-phase 200 V AC input you should contact your local sales office.
Does this -RJ model accept a DC power supply input?
DC power supply input is available only with MR-J4-_B-RJ servo amplifiers. The main circuit and control circuit DC input is 283 V DC to 340 V DC, with permissible voltage fluctuation of 241 V DC to 374 V DC; for parameter setting values when a DC input is used, refer to the Function column of [Pr. PC20] in section 5.2.3.
- Model identity
- MR-J4-100B-RJ: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 100 = 1 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class) (Note 13: when using a single-phase supply, effective load rate 75% or smaller); -RJ = fully closed loop control four-wire type/load-side encoder A/B/Z-phase input compatible/Compatible with MR-D30 functional safety unit
- Output
- Rated voltage 3-phase 170 V AC; rated current 6.0 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz (Note 13: when using a single-phase supply, effective load rate 75% or smaller); rated current 5.0 A (10.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type, and A/B/Z-phase differential output method (Note 5) (Table 1.1, printed p.1-2: fully closed loop system — two-wire type connects to CN2 (Notes 2, 3, 4); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 6: connect a thermistor to CN2); scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 5); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 5: software version A8 or later))
- SSCNET III/H communication cycle
- SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Force cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase supply only, not allowed on 1-phase supply; when closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 1.4 kg (the Mass row prints one value for the 100B and 70B columns together)
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-SR81, HG-SR102, HG-JR53, HG-JR103; of these, HG-JR53 carry the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%); POINT (§1.4, PDF p.36): when a 1-phase 200 V AC input is used, the maximum torque of 400% cannot be achieved with HG-JR series servo motor; when using the MR-J4-100B(-RJ) or MR-J4-200B(-RJ) with the 1-phase 200 V AC input, contact your local sales office for the torque characteristics of the HG-UR series, HG-RR series, and HG-JR series servo motors
- Combinations — linear / direct drive motors
- Combinations (200 V class combinations table): direct drive motors: TM-RFM018E20
- DC power supply input (-RJ only)
- DC power supply input is available only with MR-J4-_B-RJ servo amplifiers (Note 16): main circuit input 283 V DC to 340 V DC; control circuit input 283 V DC to 340 V DC; permissible voltage fluctuation: 241 V DC to 374 V DC (main circuit and control circuit); parameter setting values for DC input: refer to the Function column of [Pr. PC20] in section 5.2.3 (Note 16)