MR-J4-40B Procurement Questions
Which servo motors can be combined with the MR-J4-40B?
The 200 V class combinations table lists rotary servo motors HG-KR43 and HG-MR43, linear servo motors (primary side) LM-H3P2A-07P-BSS0, LM-H3P3A-12P-CSS0, LM-K2P1A-01M-2SS1, LM-U2PAD-10M-0SS0 and LM-U2PAF-15M-0SS0, and direct drive motors TM-RFM004C20, TM-RG2M004E30, TM-RU2M004E30, TM-RG2M009G30 and TM-RU2M009G30. TM-RG2M004E30 and TM-RU2M004E30 are available with servo amplifiers with software version C8 or later and the combination increases the rated torque and the maximum torque; TM-RG2M009G30 and TM-RU2M009G30 are available with software version C8 or later.
Does the MR-J4-40B support fully closed loop control and a load-side encoder?
Fully closed loop control and the scale measurement function are listed as compatible. The load-side encoder interface is Mitsubishi Electric high-speed serial communication, and the MR-J4-_B servo amplifier is compatible only with the two-wire type, which connects to CN2. Four-wire type and A/B/Z-phase differential output method cannot be used with MR-J4-_B_; use an MR-J4-_B_-RJ. The two-wire connection is used with software version A3 or later for the fully closed loop system and A8 or later for the scale measurement function.
What communication cycle does the SSCNET III/H interface support?
The listed SSCNET III/H communication cycles are 0.222 ms, 0.444 ms and 0.888 ms. The communication cycle depends on the controller specifications and the number of axes connected, so not all listed values are selectable under any configuration.
What functional safety does the MR-J4-40B provide?
Functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.
What are the ambient and installation conditions for the MR-J4-40B?
Operation ambient temperature is 0 °C to 55 °C (non-freezing) and storage is -20 °C to 65 °C (non-freezing); ambient humidity is 5 %RH to 90 %RH (non-condensing). Use indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt, at 2000 m or less above sea level; at altitude exceeding 1000 m and up to 2000 m, follow the restrictions in section 2.7. Close mounting is allowed on 3-phase and 1-phase supply, operating at ambient temperature 0 °C to 45 °C or at 75% or smaller effective load ratio.
What interface power supply does the MR-J4-40B require?
The interface power supply is 24 V DC ± 10% with a current capacity of 0.3 A (including the CN8 connector signals). This 0.3 A applies when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points, so it is not a fixed current draw.
- Model identity
- MR-J4-40B: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 40 = 0.4 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class)
- Output
- Rated voltage 3-phase 170 V AC; rated current 2.8 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 2.6 A (4.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B servo amplifier is compatible only with two-wire type (Note 5) (Table 1.1, printed p.1-2: fully closed loop system and scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 4 for fully closed loop; Notes 2, 3, 5 for scale measurement); four-wire type and A/B/Z-phase differential output method — MR-J4-_B_ cannot be used, use an MR-J4-_B_-RJ (Note 3); software version A3 or later (Note 4) / A8 or later (Note 5))
- SSCNET III/H communication cycle
- SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Natural cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase and 1-phase supply; operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 1.0 kg (the Mass row prints one value for the 40B and 60B columns together)
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-KR43, HG-MR43
- Combinations — linear / direct drive motors
- Combinations (200 V class combinations table): linear servo motors (primary side): LM-H3P2A-07P-BSS0, LM-H3P3A-12P-CSS0, LM-K2P1A-01M-2SS1, LM-U2PAD-10M-0SS0, LM-U2PAF-15M-0SS0; direct drive motors: TM-RFM004C20, TM-RG2M004E30, TM-RU2M004E30, TM-RG2M009G30, TM-RU2M009G30; of these, TM-RG2M004E30 and TM-RU2M004E30 carry the table’s Note 1 marker (available with servo amplifiers with software version C8 or later) and Note 3 marker (the combination increases the rated torque and the maximum torque); TM-RG2M009G30 and TM-RU2M009G30 carry the table’s Note 1 marker (available with servo amplifiers with software version C8 or later)
Technical specifications follow the cited manufacturer references.