  • Mitsubishi Electric MR-J4-10B-RJ Servo Amplifier
  • Command interface: SSCNET III/H
  • Main circuit supply: Single-phase or three-phase 200–240 V AC, 50/60 Hz
  • Rated output voltage: Three-phase 170 V AC
  • Rated output current: 1.1 A

Specification

Mitsubishi Electric MR-J4-10B-RJ — Servo Amplifier.

Technical Specifications

SpecificationDetails
ManufacturerMitsubishi Electric
Catalog numberMR-J4-10B-RJ
Command interfaceSSCNET III/H
Main circuit supplySingle-phase or three-phase 200–240 V AC, 50/60 Hz
Rated output voltageThree-phase 170 V AC
Rated output current1.1 A
Controlled axes1
Manufacturer weight reference0.8 kg — Manufacturer product mass; packaging inclusion not specified
Mitsubishi Electric — MELSERVO-J4 catalog L(NA)03058ENG-J, PDF pages 101, 102

MR-J4-10B-RJ Procurement Questions

Which load-side encoder connection methods does the MR-J4-10B-RJ support for fully closed loop control?

The MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type, and A/B/Z-phase differential output method. In Table 1.1, for the fully closed loop system the two-wire type connects to CN2, while the four-wire type and A/B/Z-phase differential output method connect to CN2L; a thermistor must be connected to CN2. For the scale measurement function, the four-wire type and A/B/Z-phase differential output method connection requires software version A8 or later.

Can this amplifier be used with a DC power supply input?

DC power supply input is available only with MR-J4-_B-RJ servo amplifiers. The main circuit input and control circuit input are 283 V DC to 340 V DC, with permissible voltage fluctuation of 241 V DC to 374 V DC for both the main circuit and the control circuit. For parameter setting values when a DC input is used, refer to the Function column of [Pr. PC20] in section 5.2.3.

What SSCNET III/H communication cycle values are listed, and can I always select any of them?

The listed SSCNET III/H communication cycle values are 0.222 ms, 0.444 ms and 0.888 ms. The communication cycle depends on the controller specifications and the number of axes connected, so not all listed values are selectable under any configuration.

What does the STO safety level depend on?

The functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not.

Which rotary servo motors are listed as combinations for this amplifier?

In the 200 V class combinations table, the MR-J4-10B(-RJ) row lists the rotary servo motors HG-KR053, HG-KR13, HG-MR053 and HG-MR13.

What are the ambient and close-mounting conditions for this amplifier?

Operation ambient temperature is 0 °C to 55 °C (non-freezing) and storage is -20 °C to 65 °C (non-freezing), with 5 %RH to 90 %RH (non-condensing) humidity, indoors with no direct sunlight and free from corrosive gas, flammable gas, oil mist, dust and dirt. Close mounting is allowed on 3-phase and 1-phase supply, but when closely mounting the servo amplifiers, operate them at the ambient temperature of 0 °C to 45 °C or at 75% or smaller effective load ratio.

Model identity
MR-J4-10B-RJ: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 10 = 0.1 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class); -RJ = fully closed loop control four-wire type/load-side encoder A/B/Z-phase input compatible/Compatible with MR-D30 functional safety unit
Output
Rated voltage 3-phase 170 V AC; rated current 1.1 A
Main circuit power supply input
Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.9 A (1.5 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Control circuit power supply input
Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Interface power supply
24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
Control method / dynamic brake
Sine-wave PWM control, current control method; dynamic brake: Built-in
Fully closed loop control / load-side encoder interface
Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B-RJ servo amplifier is compatible with two-wire type, four-wire type, and A/B/Z-phase differential output method (Note 5) (Table 1.1, printed p.1-2: fully closed loop system — two-wire type connects to CN2 (Notes 2, 3, 4); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 6: connect a thermistor to CN2); scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 5); four-wire type and A/B/Z-phase differential output method connect to CN2L (Note 5: software version A8 or later))
SSCNET III/H communication cycle
SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
Functional safety
STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
Structure (IP rating) / cooling
Natural cooling, open (IP20)
Environment
Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase and 1-phase supply; operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
Device mass
0.8 kg (the Mass row prints one value for the 10B and 20B columns together)
Combinations — rotary servo motors
Combinations with rotary servo motors (200 V class combinations table): HG-KR053, HG-KR13, HG-MR053, HG-MR13
DC power supply input (-RJ only)
DC power supply input is available only with MR-J4-_B-RJ servo amplifiers (Note 16): main circuit input 283 V DC to 340 V DC; control circuit input 283 V DC to 340 V DC; permissible voltage fluctuation: 241 V DC to 374 V DC (main circuit and control circuit); parameter setting values for DC input: refer to the Function column of [Pr. PC20] in section 5.2.3 (Note 16)

Technical specifications follow the cited manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp