MR-J4-200B Procurement Questions
Can the MR-J4-200B be run from a single-phase 200 V AC supply, and what condition applies?
Yes, the main circuit accepts 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz. When using a 1-phase 200 V AC to 240 V AC power supply, the servo amplifier must be operated at 75% or smaller effective load ratio. The rated current for the 1-phase power supply input is 15.8 A, shown in parentheses in the table.
What interface power supply does this amplifier require?
The interface power supply is 24 V DC ± 10% with a current capacity of 0.3 A, including the CN8 connector signals. That 0.3 A applies when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points, so it is not a fixed current draw.
Which load-side encoder types can be connected to the MR-J4-200B?
The MR-J4-_B_ servo amplifier is compatible only with the two-wire type load-side encoder, using Mitsubishi Electric high-speed serial communication. For the fully closed loop system and the scale measurement function, the two-wire type connects to CN2; the four-wire type and A/B/Z-phase differential output method cannot be used with MR-J4-_B_ and require an MR-J4-_B_-RJ. The two-wire connection requires software version A3 or later for the fully closed loop system and A8 or later for scale measurement.
What SSCNET III/H communication cycles are listed, and are they all always selectable?
The listed communication cycles are 0.222 ms, 0.444 ms and 0.888 ms. The communication cycle depends on the controller specifications and the number of axes connected, so not all listed values are selectable under any configuration.
What safety level does the STO function provide, and on what does it depend?
The functional safety is STO (IEC/EN 61800-5-2), with standards EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3 and EN 61800-5-2. The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and on whether STO input diagnosis by TOFB output is performed or not.
Can the MR-J4-200B be closely mounted, and which servo motors are listed for it?
Close mounting is allowed on 3-phase supply only and not allowed on 1-phase supply; when closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C or at 75% or smaller effective load ratio. The listed rotary combinations include HG-SR121, HG-SR152, HG-SR201, HG-SR202, HG-UR152, HG-RR103, HG-RR153, HG-JR73, HG-JR103, HG-JR153 and HG-JR203, with HG-JR73 and HG-JR103 carrying the 400% maximum torque marker; with a 1-phase 200 V AC input the 400% maximum torque cannot be achieved with HG-JR series servo motors, and for HG-UR, HG-RR and HG-JR torque characteristics with 1-phase input the local sales office should be contacted.
- Model identity
- MR-J4-200B: MR-J4 series servo amplifier, SSCNET III/H interface; capacity symbol 200 = 2 kW rated output; no power-supply symbol = 3-phase or 1-phase 200 V AC to 240 V AC (200 V class) (Note 13: when using a single-phase supply, effective load rate 75% or smaller)
- Output
- Rated voltage 3-phase 170 V AC; rated current 11.0 A
- Main circuit power supply input
- Voltage/frequency: 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz (Note 13: when using a single-phase supply, effective load rate 75% or smaller); rated current 10.5 A (15.8 A with 1-phase power supply input — the value in ( ) is the rated current for the 1-phase power supply input); permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Control circuit power supply input
- Voltage/frequency: 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.2 A; power consumption 30 W; permissible voltage fluctuation: 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
- Interface power supply
- 24 V DC ± 10%; current capacity 0.3 A (including the CN8 connector signals) (Note 1: 0.3 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points; not a fixed current draw)
- Control method / dynamic brake
- Sine-wave PWM control, current control method; dynamic brake: Built-in
- Fully closed loop control / load-side encoder interface
- Fully closed loop control: Compatible (Note 7); scale measurement function: Compatible (Note 10); load-side encoder interface: Mitsubishi Electric high-speed serial communication; the MR-J4-_B servo amplifier is compatible only with two-wire type (Note 5) (Table 1.1, printed p.1-2: fully closed loop system and scale measurement function — two-wire type connects to CN2 (Notes 2, 3, 4 for fully closed loop; Notes 2, 3, 5 for scale measurement); four-wire type and A/B/Z-phase differential output method — MR-J4-_B_ cannot be used, use an MR-J4-_B_-RJ (Note 3); software version A3 or later (Note 4) / A8 or later (Note 5))
- SSCNET III/H communication cycle
- SSCNET III/H communication cycle: 0.222 ms, 0.444 ms, 0.888 ms (Note 8) (Note 8: the communication cycle depends on the controller specifications and the number of axes connected; not all listed values are selectable under any configuration)
- Functional safety
- STO (IEC/EN 61800-5-2); standards: EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 (Note 14: the safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by TOFB output is performed or not)
- Structure (IP rating) / cooling
- Force cooling, open (IP20)
- Environment
- Ambient temperature: operation 0 °C to 55 °C (non-freezing), storage -20 °C to 65 °C (non-freezing); ambient humidity: operation/storage 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration resistance: 5.9 m/s2, at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust and dirt; altitude restriction (Note 15): follow the restrictions in section 2.7 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level; close mounting (Note 2): allowed on 3-phase supply only, not allowed on 1-phase supply; when closely mounted on 3-phase supply, operate at ambient temperature 0 °C to 45 °C, or at 75% or smaller effective load ratio
- Device mass
- 2.1 kg
- Combinations — rotary servo motors
- Combinations with rotary servo motors (200 V class combinations table): HG-SR121, HG-SR152, HG-SR201, HG-SR202, HG-UR152, HG-RR103, HG-RR153, HG-JR73, HG-JR103, HG-JR153, HG-JR203; of these, HG-JR73, HG-JR103 carry the table's Note 2 marker (the combination increases the maximum torque of the servo motor to 400%); POINT (§1.4, PDF p.36): when a 1-phase 200 V AC input is used, the maximum torque of 400% cannot be achieved with HG-JR series servo motor; when using the MR-J4-100B(-RJ) or MR-J4-200B(-RJ) with the 1-phase 200 V AC input, contact your local sales office for the torque characteristics of the HG-UR series, HG-RR series, and HG-JR series servo motors
- Combinations — linear / direct drive motors
- Combinations (200 V class combinations table): linear servo motors (primary side): LM-H3P3D-48P-CSS0, LM-H3P7B-48P-ASS0, LM-H3P7C-72P-ASS0, LM-FP2B-06M-1SS0, LM-K2P1C-03M-2SS1, LM-U2P2B-40M-2SS0
Technical specifications follow the cited manufacturer references.