Mitsubishi Electric MR-J4W2-44B Servo Amplifier

Series#: Mitsubishi

Product Details

  • Mitsubishi Electric MR-J4W2-44B Servo Amplifier
  • Controlled axes: 2
  • Command interface: SSCNET III/H
  • Rated output current per axis: 2.8 A
  • Main circuit supply: Single-phase or three-phase 200–240 V AC, 50/60 Hz

Specification

Mitsubishi Electric MR-J4W2-44B — Servo Amplifier.

Technical Specifications

SpecificationDetails
ManufacturerMitsubishi Electric
Catalog numberMR-J4W2-44B
Controlled axes2
Command interfaceSSCNET III/H
Rated output current per axis2.8 A
Main circuit supplySingle-phase or three-phase 200–240 V AC, 50/60 Hz
Manufacturer weight reference1.5 kg — Manufacturer product mass; packaging inclusion not specified
Mitsubishi Electric — MELSERVO-J4 catalog L(NA)03058ENG-J, PDF pages 128, 129

MR-J4W2-44B Procurement Questions

What supply voltage and frequency does the MR-J4W2-44B main circuit require?

The main circuit power supply input is 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz. Permissible voltage fluctuation is 3-phase or 1-phase 170 V AC to 264 V AC, and permissible frequency fluctuation is within ±5%.

What is the main circuit rated current with 3-phase versus 1-phase input?

The main circuit power supply rated current is 5.2 A with 3-phase input and 9.0 A with 1-phase input, the latter being the parenthesized value under Note 11.

What does the 0.35 A interface power supply capacity figure mean?

The interface power supply is 24 V DC ± 10% with a power supply capacity of 0.35 A (Note 1). Per Note 1, 0.35 A is the value applicable when all I/O signals are used; the current capacity can be decreased by reducing the number of I/O points, so it is not a fixed power consumption.

What protective functions are built into this amplifier?

Protective functions include overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, and error excessive protection.

What are the operating environment limits for the MR-J4W2-44B?

Ambient temperature is 0 °C to 55 °C in operation (non-freezing) and -20 °C to 65 °C in storage (non-freezing); ambient humidity is 5 %RH to 90 %RH (non-condensing). Altitude is 2000 m or less above sea level (Note 13), and vibration must be 5.9 m/s² or less at 10 Hz to 55 Hz in the X, Y and Z axes. It is for indoor use (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt, and close mounting is possible. When used at altitude exceeding 1000 m and up to 2000 m above sea level, follow the restrictions in section 2.7.

What cooling method and ingress protection does the amplifier use?

The structure is force cooling, open (IP20).

Model identity
MR-J4W2-44B: MR-J4W series integrated 2-axis servo amplifier; SSCNET III/H interface (B); the axis capacity symbol 44 in the model code denotes the per-axis rated output
Rated output (per axis)
0.4 kW per axis (2 axes)
Output rated voltage
3-phase 170 V AC
Output rated current (each axis)
2.8 A
Power supply input (voltage / frequency)
3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Permissible supply fluctuation
Permissible voltage fluctuation: 3-phase or 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation: within ±5%
Main circuit power supply rated current
5.2 A with 3-phase input; 9.0 A with 1-phase input (parenthesized value, Note 11)
Control circuit power supply
1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz; rated current 0.4 A; permissible voltage fluctuation 1-phase 170 V AC to 264 V AC; permissible frequency fluctuation within ±5%; power consumption 55 W
Interface power supply
24 V DC ± 10%; power supply capacity 0.35 A (Note 1); power supply capacity applies when all I/O signals are used (Note 1: the current capacity can be decreased by reducing the number of I/O points); not a fixed power consumption
Control system
Sine-wave PWM control, current control method
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection
Structure (cooling / IP rating)
Force cooling, open (IP20)
Environment
Ambient temperature: 0 °C to 55 °C in operation (non-freezing), -20 °C to 65 °C in storage (non-freezing); ambient humidity: 5 %RH to 90 %RH (non-condensing); altitude: 2000 m or less above sea level; vibration: 5.9 m/s² or less at 10 Hz to 55 Hz (directions of X, Y and Z axes); ambient conditions: indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt; close mounting: Possible; altitude above 1000 m and up to 2000 m: follow the restrictions in section 2.7 (Note 13)

Technical specifications follow the cited manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp