SICK KT5G-2P1111 Contrast sensor

Series#: SICK

Product Details

  • SICK KT5G-2P1111 contrast sensor (manufacturer part number 1015993) with a visible green LED light source.
  • Sensing distance is ≤ 10 mm from the leading edge of the lens, with a 1.2 x 4.2 mm light spot oriented vertically relative to the long side of the housing.
  • Sensitivity is set with a potentiometer; the switching output is PNP.
  • Operates on 10–30 VDC within a short-circuit-protected network rated max. 8 A, and connects via a 4-pin male M12 connector.
  • Switching frequency is 10 kHz at a light/dark ratio of 1:1, and the enclosure rating is IP67.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceKT5G-2P1111
Device type and manufacturer part numberContrast sensor; SICK part number 1015993
Sensing distance≤ 10 mm from the leading edge of the lens
Light sourceVisible green LED
AdjustmentPotentiometer
Supply voltage10–30 VDC; operate in a short-circuit-protected network, max. 8 A
Switching outputPNP
ConnectionMale M12 connector, 4-pin
Switching frequency10 kHz at light/dark ratio 1:1
Light spot1.2 x 4.2 mm; vertical relative to the long side of the housing
Enclosure ratingIP67
Manufacturer device weight400 g

SICK KT5G-2P1111 Contrast sensor

What sensing distance and light spot does the KT5G-2P1111 use?

The KT5G-2P1111 has a sensing distance of ≤ 10 mm measured from the leading edge of the lens. Its light spot measures 1.2 x 4.2 mm and is oriented vertically relative to the long side of the housing.

Which switching output and electrical connection does the KT5G-2P1111 provide?

The KT5G-2P1111 provides a PNP switching output and connects through a 4-pin male M12 connector.

Is the KT5G-2P1111 adjusted by potentiometer or by teach-in?

The KT5G-2P1111 is adjusted with a potentiometer.

Under what condition is the 10 kHz switching frequency of the KT5G-2P1111 specified?

The KT5G-2P1111 switching frequency of 10 kHz is specified at a light/dark ratio of 1:1.

What supply voltage does the KT5G-2P1111 require?

The KT5G-2P1111 operates on 10–30 VDC and must be operated in a short-circuit-protected network with a maximum rating of 8 A.

Device type and manufacturer part number
Contrast sensor; SICK part number 1015993
Sensing distance
≤ 10 mm from the leading edge of the lens
Light source
Visible green LED
Adjustment
Potentiometer
Supply voltage
10–30 VDC; operate in a short-circuit-protected network, max. 8 A
Switching output
PNP
Connection
Male M12 connector, 4-pin
Switching frequency
10 kHz at light/dark ratio 1:1
Light spot
1.2 x 4.2 mm; vertical relative to the long side of the housing
Enclosure rating
IP67

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp