| Specification | Details |
|---|---|
| Manufacturer | SICK |
| Model / order reference | LL3-TB01 |
| Device type and manufacturer part number | Fiber-optic cable; SICK part number 5308050 |
| Functional principle | Through-beam system with sender and receiver |
| Fiber-optic head | Threaded sleeve; axial light emission |
| Head thread | M4 |
| Qualified sensing range | 3600 mm with WLL80 at 8 ms, visible red light; not an amplifier-independent range |
| Minimum object diameter | 0.5 mm at optimum measuring distance and optimum setting |
| Infrared-light compatibility | No |
| Fiber length | 2000 mm |
| Bending radius | 30 mm |
| Operating temperature | -40 to +70 °C |
| Manufacturer cable weight | 37 g |
The LL3-TB01 (SICK part number 5308050) is a fiber-optic cable, not a standalone powered sensor. It is used as a through-beam system with a separate sender and receiver, and it requires a compatible fiber-optic amplifier to operate.
The LL3-TB01 is a through-beam system with a sender and a receiver. Its fiber-optic head has a threaded M4 sleeve with axial light emission.
The 3600 mm qualified sensing range applies with the WLL80 amplifier at 8 ms using visible red light. It is not an amplifier-independent range, so the achievable range depends on the amplifier and operating mode used.
The LL3-TB01 fiber is 2000 mm long and has a bending radius of 30 mm. Its operating temperature range is -40 to +70 °C.
No. The LL3-TB01 is listed as not compatible with infrared light, so it should not be paired with infrared-based amplifier configurations.
Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.