SICK LL3-DT02 Fiber-optic cable

Series#: SICK

Product Details

  • SICK LL3-DT02 fiber-optic cable, manufacturer part number 5308085, for use in a proximity system.
  • Threaded-sleeve fiber-optic head with a long end sleeve and axial light emission, in M3 head thread.
  • Qualified sensing range of 240 mm with the WLL80 amplifier at 8 ms using visible red light; this is not an amplifier-independent range.
  • Detects a minimum object diameter of 0.015 mm at optimum measuring distance and optimum setting.
  • Fiber length 500 mm with a 4 mm bending radius, for operating temperatures from -40 to +70 °C; not compatible with infrared light.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceLL3-DT02
Device type and manufacturer part numberFiber-optic cable; SICK part number 5308085
Functional principleProximity system
Fiber-optic headThreaded sleeve; long end sleeve; axial light emission
Head threadM3
Qualified sensing range240 mm with WLL80 at 8 ms, visible red light; not an amplifier-independent range
Minimum object diameter0.015 mm at optimum measuring distance and optimum setting
Infrared-light compatibilityNo
Fiber length500 mm
Bending radius4 mm
Operating temperature-40 to +70 °C
Manufacturer cable weight16 g

SICK LL3-DT02 Fiber-optic cable

Is the SICK LL3-DT02 a fiber-optic cable or a standalone powered sensor?

The LL3-DT02 is a fiber-optic cable (SICK part number 5308085), not a standalone powered sensor. It is used in a proximity system and requires a compatible fiber-optic amplifier to operate; the cable itself has no independent electrical supply or switching output.

Is the optical arrangement of the LL3-DT02 proximity or through-beam?

The LL3-DT02 is specified for a proximity system functional principle. Its fiber-optic head has a threaded sleeve with a long end sleeve and axial light emission, with an M3 head thread.

What amplifier and operating mode qualify the 240 mm sensing range of the LL3-DT02?

The 240 mm qualified sensing range applies with the WLL80 amplifier at 8 ms using visible red light. It is not an amplifier-independent range, so the achievable range depends on the amplifier and operating mode used.

What fiber length and bending radius does the LL3-DT02 have?

The LL3-DT02 fiber-optic cable has a fiber length of 500 mm and a bending radius of 4 mm. Its operating temperature range is -40 to +70 °C.

Is the LL3-DT02 compatible with infrared light?

No. The LL3-DT02 is listed as not compatible with infrared light, so it should be used with visible red light as specified for its qualified sensing range.

Device type and manufacturer part number
Fiber-optic cable; SICK part number 5308085
Functional principle
Proximity system
Fiber-optic head
Threaded sleeve; long end sleeve; axial light emission
Head thread
M3
Qualified sensing range
240 mm with WLL80 at 8 ms, visible red light; not an amplifier-independent range
Minimum object diameter
0.015 mm at optimum measuring distance and optimum setting
Infrared-light compatibility
No
Fiber length
500 mm
Bending radius
4 mm
Operating temperature
-40 to +70 °C

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp