SICK WLL180T-N474 Fiber-optic amplifier

Series#: SICK

Product Details

  • SICK WLL180T-N474 fiber-optic amplifier, manufacturer part number 6039619.
  • Stand-alone amplifier whose sensing principle and maximum sensing range depend on the optical fiber cable used.
  • Uses infrared light and provides 1 NPN output with manually selectable light/dark switching.
  • Operates on 12–24 VDC, ±10%, and connects via a 4-pin male M8 connector.
  • Listed response-time settings are ≤ 16 µs, ≤ 70 µs, ≤ 250 µs, ≤ 2000 µs and ≤ 8000 µs as alternatives; enclosure rating is IP50 according to EN 60529.

Specification

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceWLL180T-N474
Device type and manufacturer part numberFiber-optic amplifier; SICK part number 6039619
Device configurationStand-alone amplifier; sensing principle and maximum sensing range depend on the optical fiber cable used
Light typeInfrared light
Supply voltage12–24 VDC, ±10%
Digital output1 NPN output; light/dark switching manually selectable
ConnectionMale M8 connector, 4-pin
Listed response-time settings≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs; listed alternatives, not a single fixed response time
Listed switching frequencies31.2 / 7.1 / 2 kHz, or 250 / 62.5 Hz; mode-dependent alternatives
Enclosure ratingIP50 according to EN 60529
Manufacturer device weight20 g

SICK WLL180T-N474 Fiber-optic amplifier

Which output type and light type does the WLL180T-N474 use?

The WLL180T-N474 has 1 NPN output with light/dark switching manually selectable, and it uses infrared light.

Is the sensing range of the WLL180T-N474 fixed?

No. The WLL180T-N474 is a stand-alone amplifier, and its sensing principle and maximum sensing range depend on the optical fiber cable used, so no single fixed sensing distance applies to the amplifier alone.

What supply voltage and connection does the WLL180T-N474 require?

The WLL180T-N474 is specified for a supply voltage of 12–24 VDC, ±10%, and uses a 4-pin male M8 connector.

Which response-time settings are listed for the WLL180T-N474?

The listed response-time settings are ≤ 16 µs, ≤ 70 µs, ≤ 250 µs, ≤ 2000 µs and ≤ 8000 µs. These are listed alternatives, not a single fixed response time.

What enclosure rating does the WLL180T-N474 have?

The WLL180T-N474 has an enclosure rating of IP50 according to EN 60529.

Device type and manufacturer part number
Fiber-optic amplifier; SICK part number 6039619
Device configuration
Stand-alone amplifier; sensing principle and maximum sensing range depend on the optical fiber cable used
Light type
Infrared light
Supply voltage
12–24 VDC, ±10%
Digital output
1 NPN output; light/dark switching manually selectable
Connection
Male M8 connector, 4-pin
Listed response-time settings
≤ 16 µs / ≤ 70 µs / ≤ 250 µs / ≤ 2000 µs / ≤ 8000 µs; listed alternatives, not a single fixed response time
Listed switching frequencies
31.2 / 7.1 / 2 kHz, or 250 / 62.5 Hz; mode-dependent alternatives
Enclosure rating
IP50 according to EN 60529

Technical specifications and answers reviewed against the exact-model SICK manufacturer data sheet. Range, supply, output and test-condition qualifications are retained.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp