What supply voltage does the IM30-20BPS-VC1 require?
The supply voltage is 10 V DC ... 30 V DC, with a ripple of ≤ 20 % and a voltage drop of ≤ 2 V.
What is the difference between the sensing range Sn and the safe sensing range Sa on this sensor?
The sensing range Sn is 20 mm and the safe sensing range Sa is 16.2 mm; the sensor is installed flush.
Which output type and output function does this model have?
It has a PNP switching output with NO output function, wired as DC 3-wire.
What communication interface and process data does the IM30-20BPS-VC1 provide?
It provides IO-Link V1.0 at COM2 (38,4 kBaud), with a process data length of 1 Byte; Bit 0 = Sr reached and Bit 1 = Sa reached.
What ambient operating temperature and enclosure rating apply to this sensor?
The ambient operating temperature range is –25 °C ... +85 °C, and the enclosure rating is IP68 IP69K.
What housing material and mounting accessories come with this model?
The housing and sensing face are stainless steel V2A, DIN 1.4305 / AISI 303; items supplied include mounting nut, V2A stainless steel (2x).
- Part number (SICK ordering number)
- 6068722
- Housing
- Metric
- Thread size
- M30 x 1.5
- Diameter
- Ø 30 mm
- Sensing range Sn
- 20 mm
- Safe sensing range Sa
- 16.2 mm
- Installation type
- Flush
- Switching frequency
- 125 Hz
- Connection type
- Male connector M12, 4-pin
- Switching output
- PNP
- Switching output detail
- PNP
- Output function
- NO
- Electrical wiring
- DC 3-wire
- Enclosure rating
- IP68 IP69K
- Special applications
- Zones with coolants and lubricants, Difficult application conditions
- Items supplied
- Mounting nut, V2A stainless steel (2x)
- Supply voltage
- 10 V DC ... 30 V DC
- Ripple
- ≤ 20 %
- Voltage drop
- ≤ 2 V
- Time delay before availability
- ≤ 20 ms
- Hysteresis
- 1 % ... 15 %
- Reproducibility
- ≤ 5 %
- Temperature drift (of Sr)
- ≤ 10 %
- EMC
- According to EN 60947-5-2
- Continuous current Ia
- ≤ 200 mA
- Shock and vibration resistance
- 30 g, 11 ms / 10 ... 55 Hz, 1 mm
- Ambient operating temperature
- –25 °C ... +85 °C
- Housing material
- Stainless steel V2A, DIN 1.4305 / AISI 303
- Sensing face material
- Stainless steel V2A, DIN 1.4305 / AISI 303
- Housing length
- 63.5 mm
- Thread length
- 42 mm
- Tightening torque, max.
- ≤ 150 Nm
- Protection class
- III
- UL file no.
- E191603
- Communication interface
- IO-Link V1.0
- Communication interface, detail
- COM2 (38,4 kBaud)
- Process data length
- 1 Byte
- Process data structure
- Bit 0 = Sr reached
- Process data structure A
- Bit 1 = Sa reached
- SICK data sheet IM30-20BPS-VC1 — SICK-generated per-model data sheet ("SICK.COM" header, "DATA SHEET | SICK" footer with generation timestamp, SICK AG Waldkirch imprint)
Facts follow the cited model table/reference configuration. Firmware, memory areas and interface roles are kept distinct. Product/reference weight appears only in the specifications table. No shipping mass, stock, pricing or ratings inferred.
What Does Our Clients Say
Mitsubishi MR-J4
Laura Navas
Great product!
2019/12/01
Keyence sensor
EQDR SALES
Original and fast!
2020/02/22