SICK IM30-20BPS-VC1 Inductive Proximity Sensor

Series#: SICK

Product Details

  • SICK IM30-20BPS-VC1 Inductive Proximity Sensor
  • Nominal sensing range Sn: 20 mm
  • Installation type: Flush
  • Switching output: PNP
  • Output function: NO

Specification

SICK IM30-20BPS-VC1 Inductive Proximity Sensor.

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceIM30-20BPS-VC1
Nominal sensing range Sn20 mm
Installation typeFlush
Switching outputPNP
Output functionNO
Electrical wiringDC 3-wire
Connection typeMale connector M12, 4-pin
Supply voltage10–30 V DC

IM30-20BPS-VC1 Procurement Questions

What supply voltage does the IM30-20BPS-VC1 require?

The supply voltage is 10 V DC ... 30 V DC, with a ripple of ≤ 20 % and a voltage drop of ≤ 2 V.

What is the difference between the sensing range Sn and the safe sensing range Sa on this sensor?

The sensing range Sn is 20 mm and the safe sensing range Sa is 16.2 mm; the sensor is installed flush.

Which output type and output function does this model have?

It has a PNP switching output with NO output function, wired as DC 3-wire.

What communication interface and process data does the IM30-20BPS-VC1 provide?

It provides IO-Link V1.0 at COM2 (38,4 kBaud), with a process data length of 1 Byte; Bit 0 = Sr reached and Bit 1 = Sa reached.

What ambient operating temperature and enclosure rating apply to this sensor?

The ambient operating temperature range is –25 °C ... +85 °C, and the enclosure rating is IP68 IP69K.

What housing material and mounting accessories come with this model?

The housing and sensing face are stainless steel V2A, DIN 1.4305 / AISI 303; items supplied include mounting nut, V2A stainless steel (2x).

Part number (SICK ordering number)
6068722
Housing
Metric
Thread size
M30 x 1.5
Diameter
Ø 30 mm
Sensing range Sn
20 mm
Safe sensing range Sa
16.2 mm
Installation type
Flush
Switching frequency
125 Hz
Connection type
Male connector M12, 4-pin
Switching output
PNP
Switching output detail
PNP
Output function
NO
Electrical wiring
DC 3-wire
Enclosure rating
IP68 IP69K
Special applications
Zones with coolants and lubricants, Difficult application conditions
Items supplied
Mounting nut, V2A stainless steel (2x)
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 20 %
Voltage drop
≤ 2 V
Time delay before availability
≤ 20 ms
Hysteresis
1 % ... 15 %
Reproducibility
≤ 5 %
Temperature drift (of Sr)
≤ 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +85 °C
Housing material
Stainless steel V2A, DIN 1.4305 / AISI 303
Sensing face material
Stainless steel V2A, DIN 1.4305 / AISI 303
Housing length
63.5 mm
Thread length
42 mm
Tightening torque, max.
≤ 150 Nm
Protection class
III
UL file no.
E191603
Communication interface
IO-Link V1.0
Communication interface, detail
COM2 (38,4 kBaud)
Process data length
1 Byte
Process data structure
Bit 0 = Sr reached
Process data structure A
Bit 1 = Sa reached
  • SICK data sheet IM30-20BPS-VC1 — SICK-generated per-model data sheet ("SICK.COM" header, "DATA SHEET | SICK" footer with generation timestamp, SICK AG Waldkirch imprint)

Facts follow the cited model table/reference configuration. Firmware, memory areas and interface roles are kept distinct. Product/reference weight appears only in the specifications table. No shipping mass, stock, pricing or ratings inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say