SICK IME08-04NNSZW2S Inductive Proximity Sensor

Series#: SICK

Product Details

  • SICK IME08-04NNSZW2S Inductive Proximity Sensor
  • Nominal sensing range Sn: 4 mm
  • Installation type: Non-flush
  • Switching output: NPN
  • Output function: NO

Specification

SICK IME08-04NNSZW2S Inductive Proximity Sensor.

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceIME08-04NNSZW2S
Nominal sensing range Sn4 mm
Installation typeNon-flush
Switching outputNPN
Output functionNO
Electrical wiringDC 3-wire
Connection typeCable, 3-wire, 2 m
Supply voltage10–30 V DC

IME08-04NNSZW2S Procurement Questions

What supply voltage does the IME08-04NNSZW2S require?

The supply voltage is 10 V DC ... 30 V DC, with a ripple of ≤ 10 % and a voltage drop of ≤ 2 V.

Is this sensor flush-mountable, and what sensing range does it provide?

It is a non-flush installation type with a sensing range Sn of 4 mm and a safe sensing range Sa of 3.24 mm.

What switching output and output function does this model have?

This model has an NPN switching output with an NO output function, using DC 3-wire electrical wiring.

What is the maximum tightening torque for mounting?

The maximum tightening torque is ≤ 5 Nm.

What ambient operating temperature range is specified?

The ambient operating temperature range is –25 °C ... +75 °C.

What connection and cable does the sensor use?

The connection type is a 3-wire, 2 m cable with PVC cable material, 0.25 mm² conductor size and Ø 3.9 mm cable diameter.

Part number (SICK ordering number)
1040896
Housing
Cylindrical thread design
Housing (second attribute)
Standard
Thread size
M8 x 1
Diameter
Ø 8 mm
Sensing range Sn
4 mm
Safe sensing range Sa
3.24 mm
Installation type
Non-flush
Switching frequency
4,000 Hz
Connection type
Cable, 3-wire, 2 m
Switching output
NPN
Output function
NO
Electrical wiring
DC 3-wire
Enclosure rating
IP67
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2 V
Time delay before availability
≤ 100 ms
Hysteresis
5 % ... 15 %
Reproducibility
≤ 2 %
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
Cable material
PVC
Conductor size
0.25 mm²
Cable diameter
Ø 3.9 mm
Short-circuit protection
✔
Reverse-polarity protection
✔
Power-up pulse protection
✔
Shock and vibration resistance
30 g, 11 ms/10 Hz ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +75 °C
Housing material
Brass, nickel-plated
Sensing face material
Plastic, PA 66
Housing length
52 mm
Thread length
30 mm
Tightening torque, max.
≤ 5 Nm
Items supplied
Mounting nut, brass, nickel-plated (2x)
UL file no.
NRKH.E181493
MTTFD
1,735 years
  • SICK data sheet IME08-04NNSZW2S — SICK-generated per-model data sheet ("SICK.COM" header, "DATA SHEET | SICK" footer with generation timestamp, SICK AG Waldkirch imprint)

Facts follow the cited model table/reference configuration. Firmware, memory areas and interface roles are kept distinct. Product/reference weight appears only in the specifications table. No shipping mass, stock, pricing or ratings inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say