SICK IME18-12NNSZW2S Inductive Proximity Sensor

Series#: SICK

Product Details

  • SICK IME18-12NNSZW2S Inductive Proximity Sensor
  • Nominal sensing range Sn: 12 mm
  • Installation type: Non-flush
  • Switching output: NPN
  • Output function: NO

Specification

SICK IME18-12NNSZW2S Inductive Proximity Sensor.

Technical Specifications

SpecificationDetails
ManufacturerSICK
Model / order referenceIME18-12NNSZW2S
Nominal sensing range Sn12 mm
Installation typeNon-flush
Switching outputNPN
Output functionNO
Electrical wiringDC 3-wire
Connection typeCable, 3-wire, 2 m
Supply voltage10–30 V DC

IME18-12NNSZW2S Procurement Questions

What supply voltage does the IME18-12NNSZW2S require?

The sensor is specified for a supply voltage of 10 V DC ... 30 V DC, with a ripple of ≤ 10 % and a voltage drop of ≤ 2 V.

Is this sensor flush-mountable?

No. The installation type is non-flush, with a sensing range Sn of 12 mm and a safe sensing range Sa of 9.72 mm.

What switching output and output function does this model have?

This model has an NPN switching output with an NO output function, using DC 3-wire electrical wiring.

What is the maximum continuous current and switching frequency?

The continuous current Ia is ≤ 200 mA and the switching frequency is 1,000 Hz.

What ambient operating temperature range is specified?

The ambient operating temperature range is –25 °C ... +75 °C.

What connection and cable does the sensor use?

The connection type is a 3-wire cable, 2 m, with PVC cable material, conductor size 0.25 mm² and cable diameter Ø 3.9 mm.

Part number (SICK ordering number)
1040992
Housing
Cylindrical thread design
Housing (second attribute)
Standard
Thread size
M18 x 1
Diameter
Ø 18 mm
Sensing range Sn
12 mm
Safe sensing range Sa
9.72 mm
Installation type
Non-flush
Switching frequency
1,000 Hz
Connection type
Cable, 3-wire, 2 m
Switching output
NPN
Output function
NO
Electrical wiring
DC 3-wire
Enclosure rating
IP67
Supply voltage
10 V DC ... 30 V DC
Ripple
≤ 10 %
Voltage drop
≤ 2 V
Time delay before availability
≤ 100 ms
Hysteresis
5 % ... 15 %
Reproducibility
≤ 2 %
Temperature drift (of Sr)
± 10 %
EMC
According to EN 60947-5-2
Continuous current Ia
≤ 200 mA
Cable material
PVC
Conductor size
0.25 mm²
Cable diameter
Ø 3.9 mm
Short-circuit protection
✔
Reverse-polarity protection
✔
Power-up pulse protection
✔
Shock and vibration resistance
30 g, 11 ms/10 Hz ... 55 Hz, 1 mm
Ambient operating temperature
–25 °C ... +75 °C
Housing material
Brass, nickel-plated
Sensing face material
Plastic, PA 66
Housing length
67 mm
Thread length
42 mm
Tightening torque, max.
≤ 40 Nm
Items supplied
Mounting nut, brass, nickel-plated (2x)
UL file no.
NRKH.E181493
MTTFD
1,735 years
  • SICK data sheet IME18-12NNSZW2S — SICK-generated per-model data sheet ("SICK.COM" header, "DATA SHEET | SICK" footer with generation timestamp, SICK AG Waldkirch imprint)

Facts follow the cited model table/reference configuration. Firmware, memory areas and interface roles are kept distinct. Product/reference weight appears only in the specifications table. No shipping mass, stock, pricing or ratings inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp