ABB FM562 S500-eCo Pulse-Train Output Module

Series#: ABB

Product Details

  • ABB FM562 S500-eCo Pulse-Train Output Module
  • Motion axes: 2
  • Pulse outputs: 2 per axis; RS-422 differential
  • PTO frequency: 10 Hz to 250 kHz
  • Output modes: CW/CCW or pulse/direction

Specification

ABB FM562 S500-eCo Pulse-Train Output Module.

Technical Specifications

SpecificationDetails
ManufacturerABB
Order numberFM562
Motion axes2
Pulse outputs2 per axis; RS-422 differential
PTO frequency10 Hz to 250 kHz
Output modesCW/CCW or pulse/direction
Digital inputs2 configurable 24 V DC inputs per axis
Programming requirementPS552-MC-E library package, separately purchased
Axis isolationPulse outputs of the two axes are not isolated from each other
Connection accessoriesRemovable 9-pin and 11-pin terminal blocks; ordered separately
Manufacturer approximate product weightApproximately 125 g ABB reference, PDF page 639. Product/reference configuration only; shipping mass is not inferred.

FM562 Procurement Questions

What is the FM562 used for?

It is a function module for pulse train output (PTO) used for simple positioning tasks with servo drives or stepper drives, providing 2 axes with 2 inputs and 2 pulse-train outputs each.

Are the terminal blocks included with the module?

No. The connection is carried out using removable 9-pin and 11-pin terminal blocks, and these are not included in the module's scope of delivery and must be ordered separately.

Is additional software required to program the FM562?

Yes. For programming, the library package PS552-MC-E is required; it is not part of Automation Builder and has to be purchased separately.

Are the pulse outputs of the two axes galvanically isolated from each other?

No. The pulse outputs of the 2 axes are not galvanically isolated from each other.

What pulse output frequency is specified for the FM562?

The data sheet and hardware manual print a frequency of 10 Hz to 250 kHz, while the main catalog prints a frequency range of 0...250 kHz; both printings are recorded and neither is reconciled.

Which communication interface modules can the FM562 be combined with?

The main catalog lists CI501-PNIO, CI502-PNIO, CI504-PNIO, CI506-PNIO, CI541-DP and CI542-DP as suitable communication interface modules.

Module role / intended purpose
Function module for pulse train output (PTO), used for simple positioning tasks with servo drives or stepper drives; provides 2 axes with 2 inputs and 2 pulse-train outputs each
Pulse train outputs per axis
2 pulse train outputs per axis, RS-422
Digital inputs per axis
2 configurable digital inputs per axis, 24 V DC
Position registers
32 bits registers for current position, registered position and speed value
Pulse output isolation between axes
The pulse outputs of the 2 axes are not galvanically isolated from each other
Connectable devices (I/O bus)
Connectable via the I/O bus connector to S500 PROFIBUS and PROFINET communication interface modules (e. g. CI501-PNIO, CI541-DP), AC500 CPUs and other AC500 I/O modules
Suitable communication interface modules (main catalog)
CI501-PNIO, CI502-PNIO, CI504-PNIO, CI506-PNIO, CI541-DP, CI542-DP
Terminal blocks
Connection is carried out by using removable 9-pin and 11-pin terminal blocks
Terminal blocks - scope of delivery
The terminal blocks are not included in the module's scope of delivery and must be ordered separately
Digital inputs (data sheet)
4 inputs (2 per axis) 24 V DC, can be used as source inputs or as sink inputs
Input channels 0 and 2 - function
Input signal used for axis enable and limit switch
Input channels 1 and 3 - function
Stop, configurable
Input data length
32 bytes
Output data length
32 bytes
Pulse outputs per axis (data sheet)
2 outputs for each axis, configurable
Pulse output type
RS-422 differential signal
Pulse output mode
CW & CCW or Pulse & Direction
PTO frequency (data sheet / HW manual printing)
10 Hz to 250 kHz
PTO frequency range (main catalog printing)
0...250 kHz (frequency range as printed in the main catalog technical data — its lower limit differs from the data sheet / HW manual printing; both printings recorded, neither reconciled)
Pulse number range
-2147483648 to 2147483647 (32 bits)
Programming library (PS552-MC-E)
For programming, the library package PS552-MC-E is required; it is not part of Automation Builder and has to be purchased separately
Process supply voltage UP - rated value
24 V DC (process supply voltage UP, rated value)
Current consumption via UP terminal
42 mA
Current consumption from CPU power supply
Ca. 5 mA (current consumption from the 24 V DC power supply at the L+/UP and M/ZP terminals of the CPU/communication interface module)
Max. power dissipation within the module
1.2 W
Device weight (data sheet / HW manual printing)
Ca. 125 g (device weight as printed in the data sheet / HW manual technical data; not a shipping weight)
Weight per piece (main catalog ordering printing)
0.15 kg (weight per piece as printed in the main catalog ordering data; differs from the data sheet's device-weight printing — both printings recorded, neither reconciled; not a shipping weight)
Order code (data sheet printing)
1SAP 233 100 R0001 (part number spacing as printed in the data sheet ordering data)
Product life cycle phase (data sheet printing)
Classic (as printed in the data sheet ordering data — the later of the two filed printings)
Product life cycle phase (HW manual printing)
Active (as printed in the HW manual ordering data — differs from the later data sheet's 'Classic' printing; both printings recorded, neither reconciled)
Input delay
Typ. 0.1 ms ... 32 ms (configurable via software), default: 0.1 ms
Input current per channel at +24 V
Typ. 5 mA (input current per channel at input voltage +24 V)
Pulse output channels
2 per axis, 4 per module
Operating temperature (AC500-eCo system data)
0 °C ... +60 °C (horizontal mounting of modules; system data as printed in the data sheet)
Degree of protection (AC500-eCo system data)
IP 20 (PLC system degree of protection as printed in the data sheet's system data, with all modules or option boards plugged in, all terminals plugged in and all covers closed)

Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp