The Fluke 87V MAX True-RMS Digital Multimeter is engineered for the most demanding industrial, electrical, and HVAC applications. It combines the legendary accuracy of the 87V series with extreme ruggedness—IP67 waterproof and dustproof rating, plus a 4-meter drop survival. This meter delivers true-RMS measurements on distorted waveforms, a 20 kHz bandwidth with low-pass filter for variable frequency drives (VFDs), and a wide temperature range from -200°C to +1090°C. Whether you are troubleshooting motor drives, high-energy switchgear, or sensitive electronics, the Fluke 87V MAX provides the precision, safety, and durability you can rely on in the field.
| Electrical Specifications | ||
|---|---|---|
| DC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.05% + 1) | |
| Maximum Resolution | 0.1 mV | |
| AC Voltage | Range | 0.1 mV to 1000 V |
| Accuracy | ±(0.7% + 4) true-rms | |
| AC Bandwidth | 20 kHz with low pass filter; 3 dB Standard Models 1 kHz | |
| Maximum Resolution | 0.1 mV | |
| DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds max) |
| Accuracy | ±(0.2% + 2) | |
| Maximum Resolution | 0.1 μA | |
| AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds max) |
| Accuracy | ±(1.0% + 2) true-rms | |
| Maximum Resolution | 0.1 μA | |
| Resistance | Range | 0.1 Ω to 50 MΩ |
| Accuracy | ±(0.2% + 1) | |
| Maximum Resolution | 0.1 Ω | |
| Capacitance | Range | 0.01 nF to 9999 μF |
| Accuracy | ±(1% + 2) | |
| Maximum Resolution | 0.01 nF | |
| Frequency | Range | 0.5 Hz to 199.99 kHz |
| Accuracy | ±(0.005% + 1) | |
| Maximum Resolution | 0.01 Hz | |
| Duty Cycle | Maximum Duty Cycle | 99.9% |
| Accuracy | ±(0.2% per kHz + 0.1%) | |
| Maximum Resolution | 0.1% | |
| Temperature Measurement | –200.0 °C to 1090 °C / –328.0 °F to 1994.0 °F (excluding probe) | |
| 80 BK Temperature Probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater; –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater | |
| Conductance | Maximum Conductance | 60.00 nS |
| Accuracy | ±(1.0% + 10) | |
| Maximum Resolution | 0.01 nS | |
| Diode Test | Range | 2 V |
| Resolution | 0.001 V | |
| Accuracy | ±(1% + 1) | |
| Diagnostics & Data Storage | Peak Min/Max | 250 μS |
| Min/Max/Avg | Yes | |
| Reading Hold / Auto (Touch) Hold | Yes | |
| Relative Reference | Yes | |
| Display | Digital | 6000 counts updates 4/second; 19,999 counts in high–resolution mode |
| Analog Bar Graph | 32 segments, updates 40/second | |
| Backlight | Two level | |
| Low Pass Filter (VFD Measurements) | Yes | |
| Input Alert™ | Yes | |
| Safety Specifications | ||
| Safety Rating | IEC61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V | |
| Agency Approvals | CE, CSA | |
| Mechanical & General Specifications | ||
| IP Rating | IEC 60529: IP67 | |
| Power | Three AA batteries. 800 hours typical, without backlight | |
| Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
| Weight | 698.5 g (with holster) | |
| Environmental Specifications | ||
| Operating Temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
| Storage Temperature | -40 °C to + 60 °C | |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C); 0% – 70% (35 °C – 55 °C) | |
| Operating Altitude | 2000 m |
The 87V MAX is rated CAT IV 600 V and CAT III 1000 V.
The meter has an IP 67 rating.
The operating temperature range is -15 °C to +55 °C, with an extended range of -40 °C for up to 20 minutes.
Yes, it has a low pass filter for measurement on VFDs.
It uses three AA batteries, with a stated battery life of 800 hours.
Included are a removable holster with test lead storage, TL175 TwistGuard test leads, AC175 Alligator clips, an 80BK-A temperature probe and three AA batteries (installed).
Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.