Fluke 718 1G Pressure Calibrator

Series#: Fluke

Product Details

  • Fluke 718 Pressure Calibrator – a rugged, handheld instrument combining pressure measurement and loop calibration in one unit.
  • Built-in hand pump for pressure generation up to 300 psi, eliminating the need for external pressure sources.
  • Measures pressure with 0.025% full-scale accuracy using internal sensor or optional 700 Series Pressure Modules.
  • Simultaneous mA measurement and 24 V loop power supply for comprehensive transmitter testing.
  • Five-digit LCD displays pressure and current simultaneously for clear, real-time readings.
  • Rugged design with 1-meter drop test, operating temperature range -10°C to 55°C, and three-year warranty.

Specification

The Fluke 718 Pressure Calibrator is a versatile field instrument designed for process technicians and calibration engineers who demand precision and portability. This device integrates a high-accuracy pressure sensor, a built-in pneumatic pump, and a 24 mA loop measurement capability, making it ideal for calibrating pressure transmitters, transducers, and switches. The Fluke 718 supports multiple pressure ranges through its internal gauge models (1G, 30G, 100G, 300G) and can be further expanded using the extensive 700 Series Pressure Modules, covering from 0–1 inH₂O to 10,000 psi. With its intuitive interface, zero, min/max, hold, and damp functions, and compliance with CSA and EMC standards, the Fluke 718 ensures reliable performance in harsh industrial environments. Below are the detailed technical specifications.

Technical Specifications
Fluke 718 Series
Measure pressure (Internal sensor)
Accuracy 0.025% full scale
Functions Zero, min/max, hold, damp
Fluke 718 1G
Range -1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)
Resolution 0.0001 psi, 0.001 mbar, 0.0001 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 30G
Range -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)
Resolution 0.001 psi, 0.1 mbar, 0.01 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 100G
Range -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)
Resolution 0.01 psi, 0.1 mbar, 0.01 kPa
Over pressure 2x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 300G
Range -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)
Resolution 0.01 psi, 1 mbar, 0.1 kPa
Over pressure 375 psi / 25 bar
Functions Zero, Min, Max, Hold, Damp
Fluke 718 series via 700 Series Pressure Modules
Range 29 pressure modules, 0 – 1 inH₂O to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs
Resolution Per pressure module specs
Accuracy To 0.025% of full span, per pressure module specs
Functions Zero, Min, Max, Hold, Damp
Fluke 718 Series Via Built in Pump
Range -12 psi or -850 mbar to full scale. Supported Pressure Units: psi, inH₂O (4°C), inH₂O (20°C), cmH₂O (4°C), cmH₂O (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm²
Loop power range 24 V DC
Accuracy ±10%
mA Measure
Range 0 mA to 24 mA
Resolution 0.001 mA
Accuracy 0.015% + 1 count
General Specifications
Maximum voltage 30 volts (non-operating)
Temperature -40°C to 60°C
Operating temperature -10°C to 55°C
Relative humidity 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)
Operating altitude 3,000 M max
Shock 1 M drop test
Vibration Random, 2 g, 5 Hz – 500 Hz
Safety CSA C22.2 No. 1010.1: 1992
EMC EN50082-1: 1992 and EN55022: 1994 Class B
Size 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)
Weight 992 g (35 oz)
Power, battery life 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718
Battery life 4 to 20 hours typical, depending on functions used
Display LCD, 5 digit pressure and current simultaneous

Fluke 718 1G Pressure Calibrator

What pressure range and accuracy does the Fluke 718 1G cover?

The 718 1G internal sensor covers -1 PSI to +1 PSI, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa), with a resolution of 0.0001 psi and 0.001 mbar. Pressure accuracy is 0.025% full scale and the over pressure rating is 5xFS.

Can the Fluke 718 1G measure current and supply loop power?

Yes. The mA measure range is 0 mA to 24 mA with 0.001 mA resolution and 0.015 % + 1 count accuracy, and the calibrator provides 24 V dc loop power with accuracy +/- 10 %. The 5 digit LCD displays pressure and current simultaneously.

What functions are included for field work?

The instrument provides Zero, Min, Max, Hold and Damp functions, an Error % calculation for quicker pass/fail decision making in the field, and a switch test feature for quicker and more accurate pressure switch testing.

What pressure units can the Fluke 718 1G display?

Supported pressure units are psi, in H20 (4 °C), in H20 (20 °C), cm H20 (4 °C), cm H20 (20 °C), bar, mbar, kPa, inHg, mmHg and kg/cm.

Does the Fluke 718 1G have a built-in pump?

Yes, the 718 1G has a built-in pump with a range of -12 PSI or -850 mbar to full scale.

What battery and operating temperature does the Fluke 718 1G use?

It is powered by a 9V battery to ANSI/NEDA 1604A or IEC 6LR61 alkaline specification, with two batteries in the 718. Operating temperature is -10 °C to 55 °C, and the unit is listed to CSA C22.2 No. 1010.1: 1992.

Model / pressure range (718 1G)
-1 PSI to +1 PSI, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)
Resolution (718 1G)
0.0001 psi, 0.001 mbar
Over pressure (718 1G)
Over Pressure 5xFS
Functions
Zero, Min, Max, Hold, Damp
Pressure accuracy (internal sensor)
0.025% of full span
mA measure range
0 mA to 24 mA
mA measure resolution
0.001 mA
mA measure accuracy
0.015 % + 1 count
Loop power
24 V dc, accuracy +/- 10 %
Built-in pump range
-12 PSI or -850 mbar to full scale
Supported pressure units
psi, in H20 (4 °C), in H20 (20 °C), cm H20 (4 °C), cm H20 (20 °C), bar, mbar, kPa, inHg, mmHg, kg/cm
Display
LCD, 5 digit pressure and current (simultaneous)
Size / weight (718 with holster)
216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in); 992 g (35 oz) — weight with holster, per Fluke technical data
Operating temperature
-10 °C to 55 °C
Power
9V battery ANSI/NEDA 1604A or IEC 6LR61 alkaline; two batteries in 718
Error % calculation
Error % calculation for quicker pass/fail decision making in the field
Switch test
Switch test feature for quicker and more accurate pressure switch testing
Safety
CSA C22.2 No. 1010.1: 1992

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp