The MITSUBISHI MELSEC-L L60TCTT4-CM and L60TCTT4BW-CM are advanced temperature control modules designed for demanding industrial automation environments. These units provide 4 independent thermocouple input channels with PID control capability, making them ideal for applications such as plastic injection molding, packaging, and heat treatment systems. The modules feature a rugged construction, high noise immunity, and support for a wide range of thermocouple types, ensuring accurate and stable temperature regulation in harsh factory conditions.
| Parameter | Specification |
|---|---|
| Model | L60TCTT4-CM / L60TCTT4BW-CM |
| Module Type | Temperature Control Module |
| Number of Channels | 4 (thermocouple input) |
| Input Type | Thermocouple (J, K, T, E, N, R, S, B, etc.) |
| Sampling Cycle | 50 ms per channel (typical) |
| Control Method | PID (auto/self-tuning) with on/off and P/D options |
| Output Type | Open collector (L60TCTT4-CM) / Transistor (L60TCTT4BW-CM) |
| Resolution | 0.1°C (for J, K, T, E, N) / 0.5°C (for R, S, B) |
| Accuracy | ±0.3% of full scale ±1 digit |
| Cold Junction Compensation | Built-in, automatic |
| Heater Break Alarm | Yes, per channel |
| Loop Break Alarm | Yes |
| Self-Tuning | Yes (one-touch) |
| Communication | MELSEC-L bus (backplane) |
| Power Consumption | 3.5 W (max) |
| Weight | Approx. 0.15 kg |
| Dimensions (W x H x D) | 28 x 90 x 88 mm (module only) |
| Operating Temperature | 0 to 55°C |
| Storage Temperature | -25 to 75°C |
| Humidity Range | 5 to 95% RH (non-condensing) |
| Vibration Resistance | 5 to 9 Hz, 3.5 mm; 9 to 150 Hz, 1.0 G |
| Shock Resistance | 15 G (11 ms half-sine) |
| Isolation | Between channels and system: 500 VAC |
| Standards Compliance | UL, CE, RoHS |
It has 4 temperature input channels per module. Usable thermocouples are types K, J, T, E, N, R, S, B, U, L, PLII and W5Re/W26Re, sampled at 250 ms/4 channels.
Control output is transistor output with PID ON/OFF pulse or two-position control, and standard control, heating-cooling control and mix control can be combined. PID constants can be set by auto tuning.
No. In the manufacturer's manual the disconnection detection function defines the separate L60TCTT4BW variant. The L60TCTT4-CM covered here is the L60TCTT4 model without that function, so heater disconnection detection must not be specified for it.
The transistor output is an ON/OFF pulse rated at 10 to 30 V DC with a maximum load current of 0.1 A/point (0.4 A/common). The module occupies 16 I/O points and connects through one 18-point terminal block.
Indication accuracy is full scale plus/minus 0.3% at an ambient temperature of 25 plus/minus 5 degrees C (full scale plus/minus 0.7% from 0 to 55 degrees C), and cold junction temperature compensation accuracy is within plus/minus 1.0 degrees C for process values of -100 degrees C or more.
Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.