Omron CS1W-PTS56 CS Isolated Resistance Thermometer Input Unit

Series#: Omron

Product Details

  • Omron CS1W-PTS56 CS Isolated Resistance Thermometer Input Unit
  • Inputs: 8 direct platinum resistance thermometer inputs
  • Supported sensors: Pt100 (JIS/IEC) and JPt100
  • Input isolation: All inputs isolated
  • Mounting: CS-series CPU rack or CS-series expansion rack

Specification

Omron CS1W-PTS56 CS Isolated Resistance Thermometer Input Unit.

Technical Specifications

SpecificationDetails
ManufacturerOmron
Order numberCS1W-PTS56
Inputs8 direct platinum resistance thermometer inputs
Supported sensorsPt100 (JIS/IEC) and JPt100
Input isolationAll inputs isolated
MountingCS-series CPU rack or CS-series expansion rack
Current consumption0.18 A at 5 V; 0.06 A at 26 V
Connection24-point removable terminal block with lever
Dimensions (W × H × D)35 × 130 × 126 mm
Manufacturer maximum product weight450 g max. Omron reference, PDF page 49

CS1W-PTS56 Procurement Questions

Is the CS1W-PTS56 a thermocouple input unit?

No. It is an Isolated-type Resistance Thermometer Input Unit providing 8 direct platinum resistance thermometer inputs, and all inputs are isolated.

Which temperature sensors can be connected, and can inputs be configured differently?

The temperature sensor type is Pt100 (JIS, IEC) or JPt100, and the same sensor type, input range, and scaling to industrial units are used by all inputs. Up to 8 platinum resistance thermometers can be connected per Unit, with 8 separate settings for temperature sensors and input ranges.

Where can the Unit be mounted, and how many Units can be used?

It mounts to a CS-series CPU Rack or CS-series Expansion Rack; it cannot be mounted to a C200H Expansion I/O Rack or SYSMAC BUS Remote I/O Slave Rack. The maximum number of Units is 80, within the allowable current consumption and power consumption range.

How is a sensor error reported?

The Unit detects a sensor error at each input and turns ON the Sensor error Flag, with a hardware detection time of approx. 0.5 s max. The process-value overrange direction for when a sensor error occurs can be specified (high: +20 digit of the set input range; low: -20 digit of the set input range).

What current consumption does the Unit require?

Current consumption is 5 V DC at 180 mA max. and 26 V DC at 60 mA max.

What are the Unit's body dimensions?

Dimensions are 35 × 130 × 126 mm (W × H × D), and the height including the Backplane is 145 mm. These are the unit's own dimensions, not package dimensions.

Model identity and overview — Isolated-type Resistance Thermometer Input Unit (NOT a thermocouple unit)
CS1W-PTS56 is Omron's Isolated-type Resistance Thermometer Input Unit: it provides 8 direct platinum resistance thermometer inputs and sends the data to the CPU Unit each cycle; all inputs are isolated.
Model, applicable PLC, unit classification (the model's own Specifications table)
The model's own Specifications table: Model CS1W-PTS56; Applicable PLC: CS Series; Unit classification: CS-series Special I/O Unit.
Mounting position, maximum number of Units, unit numbers
Mounting position: CS-series CPU Rack or CS-series Expansion Rack (cannot be mounted to a C200H Expansion I/O Rack or SYSMAC BUS Remote I/O Slave Rack). Maximum number of Units: 80, within the allowable current consumption and power consumption range. Unit numbers: 00 to 95; Special I/O Unit numbers cannot be duplicated.
Number of temperature sensor inputs
Number of temperature sensor inputs: 8.
Temperature sensor type (Pt100 (JIS, IEC), JPt100)
Temperature sensor type: Pt100 (JIS, IEC), JPt100. The same sensor type, input range, and scaling to industrial units are used by all inputs.
Accuracy at 25 °C
Accuracy at 25 °C: ±0.3% of PV or ±0.8 °C, whichever is greater, ±1 digit max. (±0.3% of PV or ±1.6 °F, whichever is greater, ±1 digit max.) PV = process value data.
Sensing method, influence of conductor resistance, input detection current, warmup time
Sensing method: 3-wire method. Influence of conductor resistance: 0.4 °C/Ω max. Input detection current: 0.5 mA. Warmup time: 10 min.
Conversion period
Conversion period: 250 ms per 8 inputs. The maximum time to store data in the CPU Unit is the conversion period plus one CPU Unit cycle.
Sensor error detection
Sensor error detection: the Unit detects a sensor error at each input and turns ON the Sensor error Flag; hardware detection time approx. 0.5 s max. The process-value overrange direction for when a sensor error occurs can be specified (high: +20 digit of the set input range; low: -20 digit of the set input range).
Process value alarm function
Process value alarm function: process value 2-point alarm (H, L), alarm hysteresis, and ON-delay timer (0 to 60 s) are available; two alarms per input (H, L) can be output to addresses in the CIO Area specified in the Expansion Setting Area.
Isolation
Isolation: between the inputs and the PLC signal, and between each input - transformer for the power supply and photocoupler for the signals.
Insulation resistance (bound exactly as printed) and dielectric strength
Insulation resistance (as printed): 20 MΩ max. at 500 V DC, between all input terminals and external AC terminals (Power Supply Unit) and between all input terminals and the FG plate. Dielectric strength: 1,000 V AC, 50/60 Hz, 1 min, detection current 1 mA, between all input terminals and external AC terminals / FG plate; 500 V AC, 50/60 Hz, 1 min, detection current 1 mA, between all channels.
External connections, unit number settings, indicators
External connections: terminal block (detachable). Unit number settings: set by rotary switches on the front panel, from 0 to 95. Indicators: three LED indicators on the front panel (for normal operation, errors detected at the Unit, and errors detected at the CPU Unit).
Effect on CPU Unit cycle time; current consumption
Effect on CPU Unit cycle time: 0.4 ms. Current consumption: 5 V DC at 180 mA max.; 26 V DC at 60 mA max.
Dimensions — device/body dimensions (never package dimensions)
Dimensions (device/body dimensions): 35 × 130 × 126 mm (W × H × D). Note: the height including the Backplane is 145 mm. These are the unit's own dimensions, not package dimensions.
Device weight maximum, as printed in the model's own Specifications table (never a shipping weight)
Weight as printed in the model's own Specifications table: 450 g max. This is a device-weight maximum printed by the manufacturer; it is not a shipping weight.
Family-common specifications — dual attestation of dimensions/weight; terminal-block group naming this model
The common specifications for all CS-series Analog I/O Units (Section 1-4-1) print the same dimensions, 35 × 130 × 126 mm (W × H × D), and the same weight, 450 g max.; the same common table names CS1W-PTS55/-PTS56/-PDC55 as the group whose external connection terminals are a 24-point removable terminal block (with lever), M3 screws, tightening torque 0.5 N·m.
Temperature characteristics (Pt100 / JPt100)
Temperature characteristics by platinum resistance thermometer type: for Pt100 and for JPt100 alike, the set-value error when the ambient temperature changes by 1 °C is ±0.06 °C over -200 to 200 °C and 285 ppm of PV over 200 to 650 °C; the characteristics table spans the measuring range -200 to 650 °C.
Printed features (Section 2-9 Features list)
Printed features of the Unit: up to 8 platinum resistance thermometers can be connected per Unit, with 8 separate settings for temperature sensors and input ranges; Pt100 (JIS, IEC) and JPt100 can be selected; temperature sensor values are transmitted to the CPU Unit in four digits hexadecimal (binary or BCD data output can be selected); zero/span adjustment capability during operation; sensor error detection.
Published English state (bench audit inventory — completion context)
Published state (bench audit inventory): goods 283 already carries a published English GEO entry under the exact model CS1W-PTS56, titled 'CS1W-PTS56 Procurement Questions'; its manufacturer reference is this same Omron operation manual, cited scope PDF pages 49, 190, 191, and its shipping status stands UNDETERMINED_UNTIL_FULL_SPEC_CAPTURE. This wave is therefore a completion capture of the missing standard specification, not a first capture.
Published mass candidate (shipping-weight audit record — unqualified, source unverified, shipping not approved)
Shipping-weight audit record for goods 283: the published content's only mass candidate is '450 g max' taken from the Omron reference at PDF page 49, classified as an unqualified mass ('Manufacturer maximum product weight') located in a goods.content table row; the audit left its source unverified and shipping not approved. That page-49 figure is the family-common maximum printed for all CS-series Analog I/O Units in Section 1-4-1 - it is not a model-specific measured weight and never a shipping weight.

Technical facts follow the cited manufacturer reference and exact model column or explicit model-number legend. Numeric weight remains only in the specifications table with its documented product/max/unpacked basis; no shipping mass is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp