Omron CJ1W-ID201 CJ-Series 8-Point DC Input Unit

Series#: Omron

Product Details

  • Omron CJ1W-ID201 CJ-Series 8-Point DC Input Unit
  • Digital inputs: 8
  • Rated input voltage: 12–24 VDC
  • Rated input voltage range: 10.2–26.4 VDC
  • Input current: 10 mA typical at 24 VDC

Specification

Omron CJ1W-ID201 CJ-Series 8-Point DC Input Unit.

Technical Specifications

SpecificationDetails
ManufacturerOmron
Order numberCJ1W-ID201
Digital inputs8
Rated input voltage12–24 VDC
Rated input voltage range10.2–26.4 VDC
Input current10 mA typical at 24 VDC
ConnectionRemovable terminal block
Common/circuit arrangement8 independent circuits
Simultaneous-ON conditions100% simultaneously ON
Manufacturer maximum product weight110 g max. Omron reference, PDF page 6

CJ1W-ID201 Procurement Questions

What input voltage does the CJ1W-ID201 accept?

The rated input voltage is 12 to 24 V DC, and the rated input voltage range is 10.2 to 26.4 V DC.

What are the ON and OFF detection thresholds for this Input Unit?

The ON voltage/ON current is 8.8 V DC min./3 mA min., and the OFF voltage/OFF current is 3 V DC max./1 mA max.

Can the input response time be changed?

The ON response time is 8.0 ms max. and the OFF response time is 8.0 ms max.; each is possible to set to between 0 and 32 ms in the PLC Setup.

How many input circuits does the CJ1W-ID201 provide, and can all be ON at once?

It has 8 circuits (each common), and 100% simultaneously ON is supported.

What input current and input impedance should I expect at 24 V DC?

The input current is 10 mA typical (at 24 V DC), and the input impedance is 2.4 kΩ.

What internal current consumption does this unit draw from the PLC?

Internal current consumption is 5 V DC: 80 mA max.

Unit classification
12 to 24-V DC Input Unit (Terminal Block, 8 Points)
Rated input voltage
12 to 24 V DC
Rated input voltage range
10.2 to 26.4 V DC
Input impedance
2.4 kΩ
Input current
10 mA typical (at 24 V DC)
ON voltage / ON current
8.8 V DC min./3 mA min.
OFF voltage / OFF current
3 V DC max./1 mA max.
ON response time
8.0 ms max. (Possible to set to between 0 and 32 ms in the PLC Setup.)
OFF response time
8.0 ms max. (Possible to set to between 0 and 32 ms using PLC Setup)
Number of circuits
8 (each common)
Simultaneously ON points
100% simultaneously ON
Insulation resistance
20 MΩ between external terminals and the GR terminal (100 V DC)
Dielectric strength
1,000 V AC between the external terminals and the GR terminal for 1 minute at a leakage current of 10 mA max.
Internal current consumption
5 V DC: 80 mA max.
Device weight
110 g max.

Technical facts follow the cited manufacturer reference and exact model column or explicit model-number legend. Numeric weight remains only in the specifications table with its documented product/max/unpacked basis; no shipping mass is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp