Siemens 6ES7211-0BA22-0XB0 SIMATIC S7-200 CPU 221

Series#: Siemens

Product Details

  • SIEMENS SIMATIC S7-200 CPU 221 (6ES7211-0BA22-0XB0) – compact micro PLC for entry-level automation tasks.
  • Integrated 6 DC digital inputs and 4 transistor digital outputs for reliable, high-speed switching.
  • 24V DC power supply with transistor outputs rated up to 24V DC, ideal for small-scale control systems.
  • Built-in PPI communication port for easy programming and networking with other Siemens devices.
  • Programmed via STEP 7-Micro/WIN software, offering a cost-effective solution for basic automation.
  • Supports limited modular expansion for flexible I/O configuration in space-constrained applications.

Specification

The SIEMENS SIMATIC S7-200 CPU 221, with part number 6ES7211-0BA22-0XB0, is a compact and cost-efficient micro programmable logic controller designed for entry-level automation tasks. This DC-powered unit integrates 6 digital inputs and 4 transistor outputs, providing reliable, high-speed control for simple processes such as machine sequencing, conveyor control, or standalone equipment monitoring. Its built-in PPI communication interface ensures seamless integration with Siemens HMI panels and other S7-200 modules, while the STEP 7-Micro/WIN programming environment simplifies development and debugging. With a compact footprint and robust industrial design, the CPU 221 is an ideal choice for applications requiring a minimal I/O count without compromising on Siemens quality.

Specification Details
Product Type SIMATIC S7-200 CPU 221 Micro PLC
Part Number 6ES7211-0BA22-0XB0
Power Supply 24V DC (typical range: 20.4 to 28.8V DC)
Digital Inputs 6 (24V DC, sink/source)
Digital Outputs 4 (Transistor, 24V DC, 0.75A per output)
Output Type Transistor (DC)
Program Memory 4 KB (user program)
Data Memory 2 KB (retentive)
Communication Interface 1 x RS-485 (PPI protocol, up to 187.5 kbps)
High-Speed Counters 2 (single-phase, up to 30 kHz)
Real-Time Clock Included (with battery backup)
Expansion Capability Limited (supports up to 2 expansion modules, total I/O max 31)
Programming Software STEP 7-Micro/WIN (V4.0 SP9 or later)
Operating Temperature 0°C to 55°C (horizontal mounting)
Storage Temperature -40°C to 70°C
Relative Humidity 5% to 95% (non-condensing)
Dimensions (W x H x D) 90 x 80 x 62 mm
Weight Approx. 270 g
Protection Class IP20 (with enclosure)
Certification CE, cULus, FM, ATEX (Zone 2)

6ES7211-0BA22-0XB0 Procurement Questions

Can this CPU 221 be expanded with additional I/O modules?

No. The maximum number of expansion modules is None and the maximum number of intelligent modules allowed is None for this CPU.

What supply voltage does this CPU 221 require?

The nominal power supply is 120 to 240 VAC, and the AC input voltage range is 85 to 264 VAC (47 to 63 Hz).

What load can the relay outputs switch?

The relay outputs are dry contacts rated 24 VDC or 250 VAC, with a voltage range of 5 to 30 VDC or 5 to 250 VAC, a maximum rated current of 2.0 A per point and 10 A per common, and a maximum lamp load of 30 W DC; 200 W AC.

How is the program and data retained, and what backup options exist?

User data of 2048 bytes is stored permanently in EEPROM, and the super capacitor provides backup of 50 hours typical (8 hours min. at 40°C); an optional battery cartridge provides 200 days typical backup.

Does this CPU include a real-time clock?

No built-in clock is listed for this CPU; the Time-of-Day clock is provided by an optional cartridge.

What communication port and baud rates does it offer?

It has 1 RS-485 port, with PPI, DP/T baud rates of 9.6, 19.2, 187.5 kbaud.

Order number - Table A-2 CPU Order Numbers prints 6ES7 211--0BA22--0XB0 for CPU 221; the exact order number is attested inside the genuine -22-generation manual itself, not taken from a filename
6ES7 211--0BA22--0XB0
CPU model - CPU 221 (Table A-2, CPU 221 row)
CPU 221
Power supply (nominal) - 120 to 240 VAC (Table A-2, CPU 221 row)
120 to 240 VAC
Onboard inputs - 6 x 24 VDC (Table A-2, CPU 221 row)
6 x 24 VDC
Onboard outputs - 4 x Relay (Table A-2, CPU 221 row)
4 x Relay
Removable connector - No (Table A-2, CPU 221 row)
No
Module description - CPU 221 AC/DC/Relay 6 Inputs/ 4 Relays (Table A-3 CPU General Specifications)
CPU 221 AC/DC/Relay 6 Inputs/ 4 Relays
Dimensions (W x H x D) - 90 x 80 x 62 mm (Table A-3; device/body dimensions, NOT package dimensions)
90 x 80 x 62
Weight - 310 g (Table A-3, printed under the column heading 'Weight'; bound as printed device weight under its own kind - NOT a shipping weight)
310 g
Power dissipation - 6 W (Table A-3)
6W
VDC available, +5 VDC - 0 mA (Table A-3)
0 mA
VDC available, +24 VDC - 180 mA (Table A-3)
180 mA
User program size (EEPROM) - 4096 bytes (Table A-4; MERGED CELL spanning the CPU 221 + CPU 222 columns - attribution verified by pdftotext -bbox word geometry, flagged in evidence_flags)
4096 bytes
User data size (EEPROM) - 2048 bytes, stored permanently (Table A-4; MERGED CELL spanning the CPU 221 + CPU 222 columns - attribution geometry-verified as for the program-size fact)
2048 bytes (stored permanently)
Backup, super capacitor - 50 hours typical (8 hours min. at 40°C) (Table A-4; MERGED CELL spanning the CPU 221 + CPU 222 columns - attribution geometry-verified)
50 hours typical (8 hours min. at 40°C)
Backup, optional battery cartridge - 200 days typical (Table A-4, CPU 221 column)
200 days typical
Built-in digital I/O - 6 inputs/4 outputs (Table A-4, CPU 221 column)
6 inputs/4 outputs
Digital I/O image size - 256 (128 In/128 Out) (Table A-4)
256 (128 In/128 Out)
Analog I/O image size - None (Table A-4, CPU 221 column)
None
Maximum expansion modules - None (Table A-4, CPU 221 column)
None
Maximum intelligent modules - None (Table A-4, CPU 221 column)
None
Pulse catch inputs - 6 (Table A-4, CPU 221 column)
6
High-speed counters, total - 4 counters total (Table A-4, CPU 221 column)
4 counters total
High-speed counters, single phase - 4 at 30 kHz (Table A-4, CPU 221 column)
4 at 30 kHz
High-speed counters, two phase - 2 at 20 kHz (Table A-4, CPU 221 column)
2 at 20 kHz
Boolean execution speed - 0.37 µs per instruction (Table A-4, CPU 221 column)
0.37 µs per instruction
Analog adjustment - 1 with 8 bit resolution (Table A-4; the cell spans the CPU 221+222 boundary - attribution verified by word geometry)
1 with 8 bit resolution
Time-of-Day clock - Optional cartridge (Table A-4; cell span verified at p.364 word geometry - the next cell, 'Built-in', starts at the CPU 224 column)
Optional cartridge
Communication ports - 1 RS-485 port (Table A-4; cell spanning CPU 221-224, geometry-verified)
1 RS--485 port
PPI/DP/T baud rates - 9.6, 19.2, 187.5 kbaud (Table A-4)
9.6, 19.2, 187.5 kbaud
Input voltage, AC supply - 85 to 264 VAC (47 to 63 Hz) (Table A-5, AC column)
85 to 264 VAC (47 to 63 Hz)
Input current, CPU 221 with AC supply - 30/15 mA at 120/240 VAC (CPU only); 120/60 mA at 120/240 VAC (max. load) (Table A-5, AC column)
30/15 mA at 120/240 VAC (CPU only); 120/60 mA at 120/240 VAC (max. load)
Inrush current, AC supply - 20 A at 264 VAC (Table A-5, AC column)
20 A at 264 VAC
Isolation (field side to logic), AC supply - 1500 VAC (Table A-5; the text layer interleaves the Isolation and Hold-up rows - the AC-column attribution was verified by word x-coordinates, and the fact carries the full 6-line block as its quote)
1500 VAC
Hold-up time, AC supply - 20/80 ms at 120/240 VAC (Table A-5; same interleaved-row geometry verification as the isolation fact)
20/80 ms at 120/240 VAC
Fuse (non-replaceable), AC supply - 2 A, 250 V Slow Blow (Table A-5, AC column)
2 A, 250 V Slow Blow
Sensor power output voltage, AC-supply CPU - 20.4 to 28.8 VDC (Table A-5)
20.4 to 28.8 VDC
Input type - Sink/Source (IEC Type 1 Sink) (Table A-6; the manual's family-general 24 VDC input specifications, presented for all CPUs)
Sink/Source (IEC Type 1 Sink)
Input rated voltage - 24 VDC at 4 mA typical (Table A-6)
24 VDC at 4 mA typical
Input logic 1 (minimum) - 15 VDC at 2.5 mA (Table A-6)
15 VDC at 2.5 mA
Input logic 0 (maximum) - 5 VDC at 1 mA (Table A-6)
5 VDC at 1 mA
Relay output type - Dry contact (Table A-7, relay-output column)
Dry contact
Relay output rated voltage - 24 VDC or 250 VAC (Table A-7)
24 VDC or 250 VAC
Relay output voltage range - 5 to 30 VDC or 5 to 250 VAC (Table A-7)
5 to 30 VDC or 5 to 250 VAC
Relay rated current per point (maximum) - 2.0 A (Table A-7)
2.0 A
Relay rated current per common (maximum) - 10 A (Table A-7)
10 A
Relay lamp load (maximum) - 30 W DC; 200 W AC (Table A-7)
30 W DC; 200 W AC
  • Siemens official model reference — Listed model features cross-checked on 22 October 2026. Project compatibility, wiring and operating limits require the applicable Siemens documentation.

Listed features checked against official Siemens model descriptions. This is not a replacement-compatibility or installation approval.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP