Siemens 6ES7518-4FP00-3AB0 SIMATIC S7-1500 CPU 1518F-4 PN/DP ODK

Series#: Siemens

Product Details

  • Siemens 6ES7518-4FP00-3AB0 SIMATIC S7-1500 CPU 1518F-4 PN/DP ODK
  • CPU type: CPU 1518F-4 PN/DP ODK
  • Program work memory: 6 MB
  • Data work memory: 20 MB
  • Communication interfaces: PROFINET IRT with 2-port switch; PROFINET RT; Ethernet; PROFIBUS

Specification

Siemens 6ES7518-4FP00-3AB0 SIMATIC S7-1500 CPU 1518F-4 PN/DP ODK.

Technical Specifications

SpecificationDetails
ManufacturerSiemens
Order number6ES7518-4FP00-3AB0
CPU typeCPU 1518F-4 PN/DP ODK
Program work memory6 MB
Data work memory20 MB
Communication interfacesPROFINET IRT with 2-port switch; PROFINET RT; Ethernet; PROFIBUS
Memory-card requirementSIMATIC Memory Card required
Supply voltage24 VDC, permissible range 19.2–28.8 VDC
Engineering referenceTIA Portal V15 for firmware V2.5, or V14 for firmware V2.0, or later
ODK functionODK Runtime Interface
Manufacturer approximate product weight1 988 g Siemens reference, PDF page 13. Source weight basis retained; no shipping mass inferred.

6ES7518-4FP00-3AB0 Procurement Questions

Is 6ES7518-4FP00-3AB0 the same article as 6ES7518-4FP00-0AB0?

No. 6ES7518-4FP00-3AB0 is the bundle/spare-part article for the CPU 1518F-4 PN/DP ODK; the non-bundle article 6ES7518-4FP00-0AB0 is a different article and is not a substitute for this one.

Which engineering software version is required for this F-CPU component?

The card states engineering with TIA Portal from V17 (FW V2.9) / V14 (FW V2.0) or higher.

What supply voltage does the F-CPU component require?

The rated supply voltage is 24 V DC, with a permissible range from 19.2 V to 28.8 V DC; reverse polarity protection is included.

Can the F-CPU component operate without a SIMATIC Memory Card?

No. The card states that a SIMATIC Memory Card is required; the plug-in load memory supports a maximum of 32 Gbyte.

What are the ambient temperature limits for horizontal installation?

For horizontal installation the card gives 0 °C as the minimum and 60 °C as the maximum; for the display the card states 50 °C, and at an operating temperature of typically 50 °C the display is switched off.

What installation altitude is permitted?

The card gives a maximum installation altitude above sea level of 5 000 m, with restrictions for installation altitudes > 2 000 m referring to the manual.

Article number
6ES7518-4FP00-3AB0
Siemens short description (product banner)
*** spare part *** SIMATIC S7-1500F, CPU 1518F-4 PN/DP ODK, central processing unit with ODK runtime interface, 9 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFINET basic services, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card required
Product type designation
CPU 1518F-4 PN/DP ODK
HW functional status
From FS08
Firmware version
V2.9
I&M data
Yes; I&M0 to I&M3
Isochronous mode
Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central)
Engineering with TIA Portal
V17 (FW V2.9) / V14 (FW V2.0) or higher
Display diagonal
6.1 cm
Supply voltage, rated value (DC)
24 V
Supply voltage, permissible range lower limit (DC)
19.2 V
Supply voltage, permissible range upper limit (DC)
28.8 V
SIMATIC Memory Card required
Yes
Reverse polarity protection
Yes
Input current, rated value
1.55 A
Inrush current, max.
2.4 A; Rated value
Infeed power to the backplane bus
12 W
Power loss (typ.)
24 W
Work memory, program
6 Mbyte
Work memory, data
60 Mbyte
Load memory, plug-in (SIMATIC Memory Card), max.
32 Gbyte
CPU processing time, bit operations
1 ns
CPU processing time, word operations
2 ns
CPU processing time, fixed-point arithmetic
2 ns
CPU processing time, floating-point arithmetic
6 ns
CPU block elements, total
20 000; Blocks (OB, FB, FC, DB) and UDTs
Number of PROFINET interfaces
3
Number of PROFIBUS interfaces
1
Ambient temperature during operation, horizontal installation, min.
0 °C
Ambient temperature during operation, horizontal installation, max.
60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
Installation altitude above sea level, max.
5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Width
175 mm
Height
147 mm
Depth
129 mm
Device weight, approx. (as printed)
1 988 g
Article pairing, F-CPU Product Information table
6ES7518-4FP00-3AB0

Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp