Siemens 6ES7138-4DC00-0AB0 ET 200S 1STEP 5V/204kHz Positioning Module

Series#: Siemens

Product Details

  • Siemens 6ES7138-4DC00-0AB0 ET 200S 1STEP 5V/204kHz Positioning Module
  • Control function: Pulse generation for external stepping-motor power unit
  • Output interface: RS-422 differential pulse and direction
  • Maximum pulse-output frequency: 204 kHz
  • Maximum positioning distance: 1,048,575 pulses

Specification

Siemens 6ES7138-4DC00-0AB0 ET 200S 1STEP 5V/204kHz Positioning Module.

Technical Specifications

SpecificationDetails
ManufacturerSiemens
Order number6ES7138-4DC00-0AB0
Control functionPulse generation for external stepping-motor power unit
Output interfaceRS-422 differential pulse and direction
Maximum pulse-output frequency204 kHz
Maximum positioning distance1,048,575 pulses
Digital-input rolesReference cam; external STOP or pulse enable
ConfigurationDDB file or STEP 7 V5.0 SP3 and later

6ES7138-4DC00-0AB0 Procurement Questions

What is the maximum output frequency of the 6ES7138-4DC00-0AB0?

The maximum output frequency is 204 kHz.

How far can the module position in terms of pulses?

The positioning distance is up to 1 048 575 pulses.

What supply voltage does the module require?

The rated load voltage L+ is 24 VDC, with a range of 20,4 ... 28.8 V as printed.

What signal type does the module send to the power unit, and how long may that cable be?

It sends differential signals for pulses and direction to RS 422, and the cable to the power unit may be max. 100 m.

What can the digital input be used for?

The digital input can be used as reference cam, or as external STOP or external pulse enable.

What are the module dimensions?

The dimensions are 15 x 81 x 52 mm (W x H x D).

Product type designation
1STEP 5V/204kHz positioning module (6ES7138-4DC00-0AB0)
Function
generates pulses for the power units of stepping motors
Digital input functions
digital input as reference cam; digital input as external STOP or external pulse enable
Max. output frequency
204 kHz
Positioning distance
up to 1 048 575 pulses
Number of channels
1
Dimensions
15 x 81 x 52 mm (W x H x D)
Device weight (approx., as printed)
40 g
Supply voltage
24 VDC rated load voltage L+; range 20,4 ... 28.8 V (decimal comma as printed)
Sensor supply
output voltage L+ (-0.8 V); output current max. 500 mA, short-circuit proof
Current consumption from backplane bus
max. 10 mA from the backplane bus
Current consumption from load voltage
typically 40 mA from load voltage L+ (no load)
Power dissipation
typically 1.5 W
Digital input voltage
rated 24 VDC; 0 signal -30 ... 5 V; 1 signal 11 ... 30 V
Input delay
typically 4 ms
Cable length
shielded max. 1000 m; unshielded max. 600 m
Output signals to the power unit
differential signals for pulses and direction to RS 422; cable to the power unit max. 100 m
Feedback interface update rate
2 ms (update rate of the feedback interface)

Technical facts follow the exact manufacturer model table or named reference. Conflicting or unestablished numeric claims are withheld. Weight appears only in the specifications table with source basis; no shipping-weight estimate is inferred.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp