Allen-Bradley 1791ES-IB16 Safety Input Module

Series#: AllenBradley

Product Details

  • 【1791ES-IB16 ALLEN-BRADLEY COMPACTBLOCK ETHERNET/IP SAFETY INPUT MODULE】 – High-performance safety input module designed for industrial automation.
  • 16-channel safety input configuration with integrated Ethernet/IP communication for seamless integration into ControlNet and DeviceNet networks.
  • CompactBlock design reduces wiring complexity and panel space, ideal for distributed safety systems.
  • Supports SIL 3 and PL e safety ratings, ensuring robust protection in hazardous environments.
  • Built-in diagnostics and fault detection for enhanced system uptime and maintenance efficiency.

Specification

The 1791ES-IB16 ALLEN-BRADLEY COMPACTBLOCK ETHERNET/IP SAFETY INPUT MODULE is a critical component for modern safety architectures. This module integrates 16 safety-rated inputs with an embedded Ethernet/IP interface, enabling direct connection to safety controllers and programmable automation controllers. Designed for distributed I/O applications, it eliminates the need for separate safety bus couplers, reducing installation costs and complexity. The module is engineered to meet stringent global safety standards, including IEC 61508 SIL 3 and ISO 13849 PL e, making it suitable for applications such as robotic cells, conveyor systems, and packaging machinery. Its rugged enclosure and industrial-grade components ensure reliable operation in temperatures from -20°C to +60°C. With built-in short-circuit protection, cross-wire detection, and status LEDs, the 1791ES-IB16 simplifies troubleshooting and enhances system transparency.

Parameter Specification
Product Type Safety Input Module
Model 1791ES-IB16
Number of Inputs 16 (Safety Category 3/4)
Input Type Source (sourcing) or Sink (sinking) configurable
Communication Protocol EtherNet/IP (CIP Safety)
Safety Rating SIL 3 per IEC 61508, PL e per ISO 13849
Input Voltage Range 24 V DC (nominal), 19.2–28.8 V DC
Input Current (per channel) 7 mA typical at 24 V DC
Response Time ≤ 10 ms (safety input to network)
Power Supply 24 V DC (module power), 0.5 A max
Enclosure Type IP20 (NEMA 1)
Operating Temperature -20°C to +60°C (-4°F to +140°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Humidity 5% to 95% non-condensing
Dimensions (H x W x D) 120 mm x 50 mm x 75 mm (4.7 in x 2.0 in x 3.0 in)
Weight 0.35 kg (0.77 lb)
Certifications CE, UL, CSA, TÜV, ATEX (Zone 2)
Connector Type Removable terminal blocks (spring clamp or screw type)
Diagnostics LED status indicators (Power, Network, Input Status, Fault)
Protection Features Short-circuit, overcurrent, cross-wire detection

Allen-Bradley 1791ES-IB16 Safety Input Module

How many safety inputs and test outputs does the 1791ES-IB16 provide, and does it have safety outputs?

It provides 16 safety inputs and 16 test outputs; the catalog table lists no safety outputs for this model, and the power-connector footnote states the output power connector pins are NC on 1791ES-IB16 modules.

What are the electrical characteristics of the safety inputs?

The safety inputs are current sinking, IEC 61131-2 input Type 3, with on-state input min 11V DC and 3.3 mA, and off-state input max 5V DC and 1.3 mA.

What pulse test output current is allowed at 40 °C and at 60 °C for this module?

Pulse test outputs are current sourcing at 0.7 A per output; the total module rating is 8 A at 40 °C and 8 A at 60 °C for the 1791ES-IB16 module.

What is the isolation rating between input channels and network?

For the 1791ES-IB16, isolation voltage is 50V (continuous), basic insulation, type tested at 800V DC for 60 s between input channels and network.

What is the maximum input reaction time?

Input reaction time, max, is 16.2 ms plus the set values of the ON/OFF delays.

What functional safety certification and safety data are stated for this module?

It is TÜV certified for functional safety up to and including Category 4 and SIL 3, with the footnote that this applies when used with specified firmware revisions; at a 1-year proof test interval (8760 hours), PFD is 2.06E-06 and PFH is 4.98E-10 per hour for the 1791ES-IB16.

Register posture (evidence-review requirement, disclosed)
Register category original_page_or_table_review_required, original_job_status evidence_review_pending; reason recorded verbatim in the quote. Posture determined an evidence-review requirement (verify table column, hardware revision and footnotes), not a supplier-identity hold.
Model designation (catalog table)
Catalog number 1791ES-IB16: CompactBlock safety input module (Guard I/O EtherNet/IP Safety Modules user manual, About the Catalog Numbers table).
I/O configuration
16 safety inputs and 16 test outputs; the catalog table lists no safety outputs for this model (dash in the Safety Outputs column).
Network platform (document cover)
CompactBlock Guard I/O module for EtherNet/IP safety networks; the installation instructions cover catalog numbers 1791ES-IB8XOBV4 and 1791ES-IB16.
Enclosure type rating
Enclosure type rating: meets IP20.
Safety input electrical characteristics
Safety inputs: current sinking; on-state input min 11V DC and 3.3 mA; off-state input max 5V DC and 1.3 mA; IEC 61131-2 input Type 3. Printed jointly for both catalog numbers covered by the installation instructions, in their shared specifications table.
Pulse test output characteristics
Pulse test outputs: current sourcing, 0.7 A per output; total module 8 A at 40 °C and 8 A at 60 °C for the 1791ES-IB16 module (the same table prints 6 A at 60 °C for the 1791ES-IB8XOBV4 module).
No safety outputs (power-connector footnote)
This module has no safety outputs: its output power connector pins are NC (no connection) on 1791ES-IB16 modules, per the installation instructions' power-connector footnote.
Operating voltage range
Operating voltage range 19.2…28.8V DC (24V DC, -20…20%).
Communication current consumption
Communication current consumption: 250 mA at 24V DC.
Isolation voltage
Isolation voltage for the 1791ES-IB16: 50V (continuous), basic insulation, type tested at 800V DC for 60 s between input channels and network.
Weight, approx. (device weight as printed)
Weight, approx. 600 g (1.32 lb) - device weight as printed in the shared specifications table; not a packaged or shipping weight.
Dimensions (body dimensions as printed)
Dimensions (HxWxD), approx.: 80 x 196 x 77 mm (3.2 x 7.7 x 3 in.) with terminal block; 77 x 196 x 62 mm (3 x 7.7 x 2.5 in.) without terminal block. Body dimensions as printed; package dimensions are not printed (GAP).
Operating temperature
Operating temperature -20…60 °C (-4…140 °F) per IEC 60068-2-1/-2-2/-2-14 tests as printed.
Input reaction time, max
Input reaction time, max: 16.2 ms plus the set values of the ON/OFF delays.
Functional safety certification (TÜV)
TÜV certified for functional safety up to and including Category 4 and SIL 3 (certifications table; footnote: when used with specified firmware revisions).
Safety data — PFD/PFH
Safety data (user manual Appendix B safety-data table, SIL 3 dual-channel / SIL 2 single-channel data): at 1-year proof test interval (8760 hours), PFD 2.06E-06 and PFH 4.98E-10 per hour for the 1791ES-IB16.

Specifications follow the cited manufacturer documents and the approved model-specific conditions. Equipment mass is not a shipping-weight estimate.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say