Allen-Bradley 1768-PA3 Power Supply

Series#: AllenBradley

Product Details

  • Allen-Bradley 1768-PA3 Power Supply
  • Power supply input type: AC or DC; AC input range: 85-265 V AC
  • DC input range: 108-132 V DC

Specification

Allen-Bradley 1768-PA3 — Power Supply.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1768-PA3
Power supply input typeAC or DC
AC input range85-265 V AC
DC input range108-132 V DC

Ordering & Compatibility

Confirm the DC input range separately from the wider AC input range.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1768-PA3 Procurement Questions

Is the 1768-PA3 a controller or a power supply?

It is a power supply for the 1768 backplane, not a controller. No controller attributes such as user memory, I/O capacity or communication ports apply to this catalog number.

What input voltages does the 1768-PA3 accept?

It is a dual-input supply: 85…265V AC or 108…132V DC, with nominal input voltage 120V/220V AC and input frequency range 47…63 Hz.

What are the output ratings of the 1768-PA3?

Maximum output power is 90 W. The card lists 24V DC to backplane: 3.5 (printed without a current-unit glyph in the source text layer) and 24V DC to user-accessible terminal block: 0.25 A.

How is the 1768-PA3 mounted and what enclosure does it have?

Module location is DIN rail or panel mount, and the enclosure type rating is None (open-style). Mounting screw torque is 1.16 N•m (10 lb•in) using M4 or #8 screws.

What overcurrent protection does the 1768-PA3 require?

Internal overcurrent protection is a non-replaceable fuse soldered in place. Recommended external overcurrent protection is 4…6 A @ 28.5…36.7 A2S, and overcurrent protection is 15 A, user supplied.

What environmental range does the 1768-PA3 support?

Operating temperature is 0 °C< Ta < 60 °C (32 °F< Ta < 140 °F), storage is -40…+85 °C (-40…+185 °F), and relative humidity is 5…95% noncondensing.

Catalog number
1768-PA3
Input voltage range AC
85…265V AC
Input voltage range DC
108…132V DC
Input voltage nom
120V/220V AC
Input frequency range
47…63 Hz
Input power max
120VA/120 W
Output power max
90 W
Backplane output
24V DC to backplane: 3.5
User terminal output
24V DC to user-accessible terminal block: 0.25 A
Output power min backplane
24V DC to backplane: 0.25 A
Power dissipation
30 W
Inrush current, max (AC low range)
50 A @ 85…132V AC
Inrush current, max (AC high range)
80 A @ 195…265V AC
Isolation voltage input
250V, reinforced insulation type, input to system and 24V DC AUX; tested at 4250V DC for 60 s
Isolation voltage aux
150V, basic insulation type, 24V DC AUX to system; tested at 2200V DC for 60 s
Internal overcurrent protection
Non-replaceable fuse is soldered in place
Recommended external overcurrent protection
4…6 A @ 28.5…36.7 A2S
Overcurrent protection max
15 A, user supplied
Weight, approx.
0.98 kg (2.15 lb)
Dimensions, approx.
131.25 x 132.75 x 105.50 mm (5.17 x 5.23 x 4.15 in.)
Module location
DIN rail or panel mount
Mounting screw torque
1.16 N•m (10 lb•in) - use M4 or #8 screws
Wire category
1 - on power ports
Wire size input power terminal
14 AWG (2.5 mm2) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation maximum
Wire size output power terminal
14 AWG (2.5 mm2)…22 AWG (0.25 mm2) solid or stranded copper wire rated at 75 °C (167 °C) or greater, 1.2 mm (3/64 in.) insulation max
Conductor screw torque
0.6 N•m (5 lb•in)
North American temperature code
T4
Ride through interval min
25 ms @ 90 W
Full power hold up interval
5 ms @ 90 W
Extended hold up interval
8...12 s @ 1.25 W
Output 2 voltage (front panel)
18...27.60V @ front panel
Enclosure type rating
None (open-style)
Temperature operating
0 °C< Ta < 60 °C (32 °F< Ta < 140 °F)
Temperature storage
-40…+85 °C (-40…+185 °F)
Relative humidity
5…95% noncondensing
Vibration
5 g at 10…500 Hz
Shock operating
30 g
Shock nonoperating
50 g
Certification — UL listing
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
Certification — UL hazardous-location listing
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp