Allen-Bradley 1769-IF4XOF2 Combination I/O Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1769-IF4XOF2 Combination I/O Module
  • Inputs: 4 differential or single-ended; Outputs: 2 single-ended
  • Signal ranges: 0–10 V / 0–20 mA

Specification

Allen-Bradley 1769-IF4XOF2 — Combination I/O Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1769-IF4XOF2
Inputs4 differential or single-ended
Outputs2 single-ended
Signal ranges0–10 V / 0–20 mA
Manufacturer approximate product weight0.29 kg — packaging inclusion not specified
1769-TD006H-EN-P (November 2023), p. 35

Ordering & Compatibility

IF4XOF2 and IF4FXOF2F do not have the same ranges or conversion specifications.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1769-IF4XOF2 Procurement Questions

What input and output ranges does the 1769-IF4XOF2 support?

The module accepts 0…10V and 0…20 mA inputs and provides 0…10V and 0…20 mA outputs.

How many inputs and outputs does this module have?

It has 4 differential or single-ended inputs and 2 single-ended outputs.

What happens when the input exceeds the normal operating range?

The over- or under-range flag comes on when the normal operating range is exceeded; the module continues to convert the analog input up to the maximum full scale range of 0…10.5V or 0…21 mA, and the flag automatically resets when within the normal operating range.

What accuracy can I expect from the inputs and outputs?

Input accuracy is ±0.6% full scale for current and ±0.7% full scale for voltage at 25 °C (77 °F), including offset, gain, nonlinearity, and repeatability error terms; output accuracy is ±0.5% full scale for both current and voltage at 25 °C (77 °F), including offset, gain, nonlinearity, and repeatability error terms.

What are the output load limits?

The current output supports a resistive load of 0…300 Ω (includes wire resistance), the voltage output requires a load greater than 1 kΩ, and the maximum current load on the voltage output is 10 mA.

Which power supplies are listed for this module and how far from the supply can it be placed?

The listed power supplies are 1769-PA2, 1769-PB2, 1769-PA4, and 1769-PB4, and the power supply distance rating is 8 modules.

Current draw @ 5.1V
120 mA
Current draw @ 24V
160 mA
Heat dissipation, max
3.03 W
Weight, approx (product weight as published)
290 g (0.64 lb)
Dimensions (HxWxD), approx
118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) Height with mounting tabs 138 mm (5.43 in.)
Slot width
1
Module location
DIN rail or panel mount
Power supply
1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
Power supply distance rating
8 modules
Terminal screw torque
0.68 N·m (6 lb·in)
Retaining screw torque
0.46 N·m (4.1 lb·in)
Wire size
(22…14 AWG) solid (22…16 AWG) stranded
Wire type
Cu-90 °C (194 °F)
Replacement terminal block
1769-RTBN18 (1 per kit)
Replacement door label
1769-RL2 series B (2 per kit)
Replacement door
1769-RD (2 per kit)
Vendor ID code
1
Product type code
10
Product code
33
Enclosure type rating
None (open-style)
Inputs
4 differential or single-ended
Input range
0…10V 0…20 mA
Full scale range
0…10.5V 0…21 mA (footnote (1) of Table 13: The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module will continue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normal operating range.)
Converter type
Successive approximation
Resolution
8 bits plus sign (footnote (2) of Table 13: Resolution is dependent upon your filter selection. The maximum resolution is achieved with either the 50 or 60 Hz filter selected.)
Response speed per channel
5 ms
Rated working voltage
30V AC/30V DC (footnote (3) of Table 13: Rated working voltage is the maximum continuous voltage that can be applied at the input terminal, including the input signal and the value that floats above ground potential (for example, 10V DC input signal and 20V DC potential above ground).)
Common mode voltage range
10V DC max per channel (footnote (4) of Table 13: For proper operation, both the plus and minus input terminals must be within ±10V DC of analog common.)
Common mode rejection
> 60 dB @ 50 and 60 Hz with the 10 Hz filter selected
Input impedance
Current: 150 Ω Voltage: 150 kΩ
Accuracy
Current: ±0.6% full scale @ 25 °C (77 °F) Voltage: ±0.7% full scale @ 25 °C (77 °F) (footnote (5) of Table 13: Includes offset, gain, nonlinearity, and repeatability error terms.)
Overall accuracy
Current: ±0.8% full scale @ 0…60 °C (32…140 °F) Voltage: ±0.9% full scale @ 0…60 °C (32…140 °F)
Accuracy drift with temperature
Current: ±0.006% per °C Voltage: ±0.006% per °C
Nonlinearity
±0.4%
Repeatability
±0.4% (7) (footnote (6) of Table 13: Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal.)
Overload at input terminals, max
Current: ±32 mA continuous, ±5V DC Voltage: ±20V DC continuous, 0.1 mA
Isolation voltage
500V AC or 710V DC for 1 minute (qualification test), group to bus 30V AC/30V DC working voltage (IEC Class 2 reinforced insulation)
Outputs
2 single-ended
Output range
0…10V 0…20 mA
Converter type
Resistor string
Response speed per channel
0.3 ms for rated resistance and rated inductance 3.0 ms for rated capacitance
Current load on voltage output, max
10 mA
Resistive load on current output
0…300 Ω(includes wire resistance)
Load range on voltage output
> 1 kΩ
Inductive load, max
Current: 0.1 mH; Voltage: 1 µF
Accuracy
Current: ±0.5% full scale @ 25 °C (77 °F) Voltage: ±0.5% full scale @ 25 °C (77 °F) (footnote (2) of Table 14: Includes offset, gain, nonlinearity, and repeatability error terms.)
Overall accuracy
Current: ±1.0% full scale @ 0…60 °C (32…140 °F) Voltage: ±0.6% full scale @ 0…60 °C (32…140 °F)
Accuracy drift with temperature
Current: ±0.01% per °C Voltage: ±0.01% per °C
Output ripple
±0.05% @ 0…50 kHz (footnote (3) of Table 14: Output ripple is the amount a fixed output varies with time, assuming a constant load and temperature.)
Repeatability
±0.05% (footnote (4) of Table 14: Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal.)
Output impedance
10 kΩ
Open and short-circuit protection
Yes
Short-circuit, max
40 mA
Open circuit, max
15V
Output response at system powerup and power down
+2.0…-1.0V DC spike for < 6 ms
Isolation voltage
500V AC or 710V DC for 1 min (qualification test), output group to bus 30V AC/30V DC working voltage (IEC Class 2 reinforced insulation)
Response speed
Fixed filter frequency 2.7 kHz; filter cut-off frequency 2.7 kHz; step response time: 63% complete in 59 µs; 90% complete in 136 µs (nom)

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp