Allen-Bradley 1769-OF8V Analog Output Module

Series#: AllenBradley

Product Details

  • Allen-Bradley 1769-OF8V Analog Output Module
  • Outputs: 8 single-ended
  • Signal type: Voltage

Specification

Allen-Bradley 1769-OF8V — Analog Output Module.

Technical Specifications

SpecificationDetails
ManufacturerAllen-Bradley
Catalog number1769-OF8V
Outputs8 single-ended
Signal typeVoltage
Manufacturer approximate product weight0.263 kg — packaging inclusion not specified
1769-TD006H-EN-P (November 2023), p. 52

Ordering & Compatibility

Verify shared analog-common wiring and avoid claiming channel-to-channel isolation.

Match the complete catalog number, hardware series, installed configuration and required accessories before ordering. Unit condition, package contents, delivery and warranty must be confirmed in the quotation.

1769-OF8V Procurement Questions

Which output ranges does the 1769-OF8V support?

The module provides 8 single-ended outputs with selectable ranges of ±10V, 0…10V, 0…5V and 1…5V.

What accuracy can I expect at 25 °C (77 °F)?

Accuracy is ±0.5% full scale @ 25 °C (77 °F); this figure includes offset, gain, nonlinearity, and repeatability error terms. Accuracy drift with temperature is ±0.0086% per °C.

What load can the voltage outputs drive?

Load range output is > 1 kΩ, load output current max is 10 mA, and capacitive load (voltage outputs) max is 1 PF.

How fast does the module convert all channels?

Conversion rate (all channels), max is 5.0 ms, and step response to 63% is < 2.9 ms.

What supply current does the module draw?

Current draw is 145 mA @ 5.1V and 125 mA @ 24V. With the optional 24V DC Class 2 power supply, whose voltage range is 20.4…26.4V DC, the 24V DC current draw from the bus is 0 mA.

What isolation does the module provide?

Isolation voltage is 500V AC or 710V DC for 1 min (qualification test), output group to bus, with 30V AC/30V DC working voltage (IEC Class 2 reinforced insulation).

Outputs
8 single-ended
Output range
±10V 0…10V 0…5V 1…5V
Full scale range
±10.5V -0.5…10.5V -0.5…5.25V 0.5…5.25V (footnote (1) of Table 74: The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module will continue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normal operating range.)
Resolution
16 bits plus sign (bipolar) ±10V DC: 15.89 bits, 330 PV/bit 0…10V DC: 14.89 bits, 330 PV/bit 0…5V DC: 13.89 bits, 330 PV/bit 1…5V DC: 13.57 bits, 330 PV/bit
Current draw @ 5.1V
145 mA
Current draw @ 24V
125 mA
Heat dissipation, max
2.16 W
Conversion rate (all channels), max
5.0 ms (2)
Step response to 63%
< 2.9 ms
Load output current, max
10 mA
Load range output
> 1 kΩ
Capacitive load (voltage outputs), max
1 PF
Field calibration
None required
Accuracy
±0.5% full scale @ 25 °C (77 °F) (footnote (3) of Table 74: Includes offset, gain, nonlinearity, and repeatability error terms.)
Accuracy drift with temperature
±0.0086% per °C
Output ripple
±0.05% @ 0…50 kHz (footnote (4) of Table 74: Output ripple is the amount a fixed output varies with time, assuming a constant load and temperature.)
Nonlinearity
±0.05%
Repeatability
±0.05% (footnote (5) of Table 74: Repeatability is the ability of the input module to register the same reading in successive measurements for the same input signal.)
Module error
±0.8%
Offset error
±0.05%
Output impedance
<1:
Open and short-circuit protection
Yes
Short-circuit protection, max
30 mA
Output overvoltage protection
Yes
Output response at system powerup and power down
± 0.5V DC spike for < 5 ms
Rated working voltage
30V AC/30V DC (footnote (6) of Table 74: Rated working voltage is the maximum continuous voltage that can be applied at the input terminal, including the input signal and the value that floats above ground potential (for example, 10V DC input signal and 20V DC potential above ground).)
Isolation voltage
500V AC or 710V DC for 1 min (qualification test), output group to bus 30V AC/30V DC working voltage (IEC Class 2 reinforced insulation)
Weight, approx (product weight as published)
263 g (0.58 lb)
Dimensions (HxWxD), approx
118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.) Height with mounting tabs 138 mm (5.43 in.)
Slot width
1
Module location
DIN rail or panel mount
Power supply
1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
Optional 24V DC Class 2 power supply voltage range
20.4…26.4V DC (footnote (7) of Table 74: If the optional 24V DC Class 2 power supply is used, the 24V DC current draw from the bus is 0 mA.)
Power supply distance rating
8 modules
Terminal screw torque
0.68 N·m (6 lb·in)
Retaining screw torque
0.46 N·m (4.1 lb·in)
Wire size
(22…14 AWG) solid (22…16 AWG) stranded
Wire type
Cu-90 °C (194 °F)
Replacement terminal block
1769-RTBN18 (1 per kit)
Replacement door label
1769-RL2 (2 per kit)
Replacement door
1769-RD (2 per kit)
Vendor ID code
1
Product type code
10
Product code
39
Input words
11
Output words
9
Configuration words
64
Enclosure type rating
None (open style)

Technical specifications are based on the linked manufacturer references.

Unmatched Customer Service

After Hours Shipping

Real Time Order Tracking

Flexible Delivery Options

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4

Laura Navas

Great product!

2019/12/01

Keyence sensor

EQDR SALES

Original and fast!

2020/02/22

Need Professional Tech Support or a Quote?

  • Our senior engineers provide 1-on-1 selection & configuration advice
  • 100% genuine products guaranteed with rapid global delivery
UP
WhatsApp